OSHA SearchOSHA records by employer

Coastal Warehouse, Ltd: OSHA inspections and violations

Wharton, Texas · Farm Product Warehousing and Storage · NAICS 493130

4inspections
20citation items
$2,484current penalties
Sep 1, 2015last inspection

OSHA has inspected Coastal Warehouse, Ltd 4 times in Texas since 1984.

The latest one began on Sep 1, 2015 as a planned inspection, in El Campo.

Those inspections ended with 20 citation items: 9 serious and 11 other-than-serious.

Penalties were first proposed at $4,160 and now stand at $2,484, 40% lower after settlements or reviews.

Belts, pulleys and power-transmission parts comes up most often in these citations: 4 items under 1910.219.

How that compares: the median penalty per cited inspection for transportation and warehousing employers since 2015 is $3,558, and Coastal Warehouse, Ltd averages $1,920 (1 cited inspection).

Coastal Warehouse, Ltd also files yearly injury logs with OSHA, summarized below.

Coastal Warehouse, Ltd: OSHA citation items per year, 1984 to 2015
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

393employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Coastal Warehouse, Ltd and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340888882 OPENED SEP 1, 2015Closed

Planned · Complete · Safety · 17 employees at the site · Closed Oct 20, 2015

101 August Street, El Campo, TX 77437 · Farm Product Warehousing and Storage · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(a)(2) · Guarding floor and wall openings and holes
Serious$1,600$960Sep 25, 2015Final
Citation 1, item 2
29 CFR 1910.242(b) · Hand and power tools
Serious$1,600$960Sep 25, 2015Final

Inspection 110395167 OPENED MAY 8, 1990Closed

Planned · Complete · Safety · 6 employees at the site · Closed Aug 10, 1990

4 Miles South Hwy 35, Tivoli, TX 77990 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$200$100May 23, 1990Closed
Citation 1, item 1b
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$0$0May 23, 1990Closed
Citation 1, item 2
29 CFR 1910.252(a)(2)(iib) · Welding fire safety
Serious$120$60May 23, 1990Closed
Citation 1, item 3
29 CFR 1910.252(a)(2)(iid) · Welding fire safety
Serious$120$60May 23, 1990Closed
Citation 1, item 4
29 CFR 1910.272(l)(4) · Grain handling facilities
Serious$280$224May 23, 1990Closed
Citation 1, item 5
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$120$60May 23, 1990Closed
Citation 1, item 6
29 CFR 1910.1200(g)(8) · Hazard communication
Serious$120$60May 23, 1990Closed
Citation 2, item 1 Other-than-serious$0$0May 23, 1990Closed
Citation 2, item 2
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Other-than-serious$0$0May 23, 1990Closed
Citation 2, item 3
29 CFR 1910.23(d)(1)(iii) · Guarding floor and wall openings and holes
Other-than-serious$0$0May 23, 1990Closed
Citation 2, item 4
29 CFR 1910.272(l)(3) · Grain handling facilities
Other-than-serious$0$0May 23, 1990Closed

Inspection 100303320 OPENED SEP 11, 1985Closed

Planned · Complete · Safety · 7 employees at the site · Closed Oct 8, 1985

602 N Sunset, Wharton, TX 77488 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(d)(2)(i) · Flammable liquids
Other-than-serious$0$0Sep 24, 1985Closed
Citation 1, item 2
29 CFR 1910.106(d)(7)(iii) · Flammable liquids
Other-than-serious$0$0Sep 24, 1985Closed
Citation 1, item 3
29 CFR 1910.106(g)(9) · Flammable liquids
Other-than-serious$0$0Sep 24, 1985Closed
Citation 1, item 4a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Other-than-serious$0$0Sep 24, 1985Closed
Citation 1, item 4b
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Other-than-serious$0$0Sep 24, 1985Closed
Citation 1, item 5
29 CFR 1910.307(b) · Hazardous (classified) locations
Other-than-serious$0$0Sep 24, 1985Closed

Inspection 1402221 OPENED JUL 20, 1984Closed

Planned · Complete · Health · 25 employees at the site · Closed Sep 5, 1984

602 N Sunset, Wharton, TX 77488 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(a)(2) · Respiratory protection
Other-than-serious$0$0Aug 2, 1984Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Wharton site logged 0 recordable injuries or illnesses among about 48 workers: 0.0 per 100 full-time workers, against a median of 0.0 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Coastal Warehouse, LTD
Wharton · 2025
48 000.00.0
Coastal Warehouse Ltd (2)
Wharton · 2024
46 000.00.0
Coastal Warehouse Ltd
Wharton · 2023
48 000.00.0
Coastal Warehouse, Ltd.
Wharton · 2021
44 000.00.0

Included with any plan: 5 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(2)(i)

(2) Design, construction, and capacity of containers—(i) General. Only approved containers and portable tanks shall be used. Metal containers and portable tanks meeting the requirements of and containing products authorized by chapter I, title 49 of the Code of Federal Regulations (regulations issued by the Hazardous Materials Regulations Board, Department of Transportation), shall be deemed to be acceptable.

29 CFR 1910.106(d)(7)(iii)

(iii) Open flames and smoking. Open flames and smoking shall not be permitted in flammable liquid storage areas.

29 CFR 1910.106(g)(9)

(9) Fire control. Each service station shall be provided with at least one fire extinguisher having a minimum approved classification of 6 B, C, located so that an extinguisher, will be within 75 feet of each pump, dispenser, underground fill pipe opening, and lubrication or service room.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.20

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.272 · Grain handling facilities

29 CFR 1910.307 · Hazardous (classified) locations