OSHA SearchOSHA records by employer

Colmac Coil Midwest, Inc.: OSHA inspections and violations

Paxton, Illinois · Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing · NAICS 333415

2inspections
3citation items
$14,745current penalties
Jul 1, 2021last inspection

Since 2016, OSHA inspectors have visited Colmac Coil Midwest, Inc. in Illinois 2 times.

The most recent inspection opened on Jul 1, 2021 on a referral, in Paxton.

In all, OSHA issued 3 citation items: 3 serious.

The proposed penalties came to $24,576; today they stand at $14,745, 40% less.

The rule cited most here is 1910.147 (lockout/tagout), 3 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Colmac Coil Midwest, Inc. averages $14,745 across 1 cited inspection.

Colmac Coil Midwest, Inc. also files yearly injury logs with OSHA, summarized below.

It reported 1 severe injury to OSHA since 2015.

Colmac Coil Midwest, Inc.: OSHA citation items per year, 2016 to 2021
Citation items per year, by inspection date.

Illinois · latest 90 days of OSHA records

426employers cited

Get notified the morning OSHA posts each new citation in Illinois: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Illinois

Checking a subcontractor, a client or your own company? Watch Colmac Coil Midwest, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345397137 OPENED JUL 1, 2021Closed

Referral · Partial · Safety · 115 employees at the site · Closed Jan 14, 2022

350 Baltimore Dr, Paxton, IL 60957 · Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Jun 29, 2021: Employee fractures lower arm in press dies, requires surgery

At 1:15 p.m. on June 29, 2021, an employee working as a pressing machine operator for an HVAC and commercial refrigeration equipment manufacturer was operating an Oak Fin Model FP-3B Progressive Die Press. The employee noticed the aluminum sheet had become stuck to the top die. The employee placed his hand between the top and bottom die to dislodge the metal sheet. The press cycled while the employee had his hand inside the point of operation. The employee was hospitalized to treat bone fractures to his arm, which required surgery.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$12,288$7,372Dec 13, 2021Final
Citation 1, item 1b
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Serious$0$0Dec 13, 2021Final
Citation 1, item 2
29 CFR 1910.147(d) · Lockout/tagout
Serious$12,288$7,372Dec 13, 2021Final

Inspection 341276905 OPENED FEB 22, 2016Closed

Complaint · Partial · Safety · 96 employees at the site · Closed Mar 4, 2016

350 Baltimore Dr, Paxton, IL 60957 · Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Paxton site logged 3 recordable injuries or illnesses among about 158 workers: 1.8 per 100 full-time workers, against a median of 2.4 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Colmac Coil Midwest, Inc.
Paxton · 2025
158 301.82.4

Included with any plan: 6 more yearly logs from these sites, back to 2019, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Jun 29, 2021, Paxton: Hospitalization · fractures · arm(s), unspecified

An employee's right arm was fractured on a fin press.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(4)(i)

(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.

29 CFR 1910.147(c)(7)(i)

(7) Training and communication. (i) The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees. The training shall include the following:

29 CFR 1910.147(d)

(d) Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence:

Other air-conditioning and warm air heating equipment and commercial and industrial refrigeration equipment manufacturing employers in Illinois

Alert subscribers get notified of each newly cited employer in Illinois the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.