Inspection 344540331 OPENED JAN 6, 2020Closed
188 Candlewood Rd., Bay Shore, NY 11706 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Colonie Plastics Corp has 6 OSHA inspections on record in New York, the first in 1987.
OSHA's last visit started on Jan 6, 2020 on a referral, in Bay Shore.
Across those inspections OSHA issued 25 citation items: 16 serious and 9 other-than-serious.
OSHA proposed $29,936 in penalties. After settlements and reviews the total is $17,100, down 43%.
Most often, OSHA cited 1910.1200, hazard communication (7 items).
For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. Colonie Plastics Corp averages $9,000 over 1 cited inspection in that time.
New York · latest 90 days of OSHA records
358employers cited
3 of them in the same industry
Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in New York
Checking a subcontractor, a client or your own company? Watch Colonie Plastics Corp and get notified the morning OSHA posts a new citation for it.
Watch this company188 Candlewood Rd., Bay Shore, NY 11706 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
188 Candlewood Rd., Bay Shore, NY 11706 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.157(g)(1) · Portable fire extinguishers |
Serious | $5,304 | $3,000 | Jan 9, 2020 | Final |
| Citation 1, item 2 29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks |
Serious | $5,304 | $3,000 | Jan 9, 2020 | Final |
| Citation 1, item 3a 29 CFR 1910.1200(e)(1) · Hazard communication |
Serious | $3,978 | $3,000 | Jan 9, 2020 | Final |
| Citation 1, item 3b 29 CFR 1910.1200(h)(1) · Hazard communication |
Serious | $0 | $0 | Jan 9, 2020 | Final |
188 Candlewood Road, Bay Shore, NY 11706 · All Other Plastics Product Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.37(a) · Exit routes |
Serious | $2,500 | $1,500 | May 28, 2003 | Closed |
| Citation 1, item 2 29 CFR 1910.110(e)(4)(iii) · Storage and handling of liquefied petroleum gases |
Serious | $750 | $250 | May 28, 2003 | Closed |
| Citation 1, item 3 29 CFR 1910.141(a)(3)(i) · Sanitation |
Serious | $2,500 | $1,500 | May 28, 2003 | Closed |
| Citation 1, item 4 29 CFR 1910.147(c)(1) · Lockout/tagout |
Serious | $2,500 | $2,000 | May 28, 2003 | Closed |
| Citation 1, item 5 29 CFR 1910.147(c)(7)(i) · Lockout/tagout |
Serious | $1,250 | $0 | May 28, 2003 | Closed |
| Citation 1, item 6 29 CFR 1910.151(c) · First aid and eyewash |
Serious | $1,000 | $750 | May 28, 2003 | Closed |
| Citation 1, item 7 29 CFR 1910.178(g)(2) · Forklifts and other powered industrial trucks |
Serious | $750 | $0 | May 28, 2003 | Closed |
| Citation 1, item 8 29 CFR 1910.212(a)(3)(ii) · Machine guarding |
Serious | $1,250 | $750 | May 28, 2003 | Closed |
| Citation 1, item 9 29 CFR 1910.212(a)(4) · Machine guarding |
Serious | $1,250 | $750 | May 28, 2003 | Closed |
| Citation 1, item 10 29 CFR 1910.304(e)(1)(iv) · Grounding and circuit protection |
Serious | $750 | $250 | May 28, 2003 | Closed |
| Citation 1, item 11 29 CFR 1910.305(b)(1) · Electrical wiring methods |
Serious | $750 | $250 | May 28, 2003 | Closed |
| Citation 2, item 1 29 CFR 1910.37(a)(4) · Exit routes |
Other-than-serious | $0 | $0 | May 28, 2003 | Closed |
| Citation 2, item 2 29 CFR 1910.178(l) · Forklifts and other powered industrial trucks |
Other-than-serious | $0 | $0 | May 28, 2003 | Closed |
| Citation 2, item 3 29 CFR 1910.178(q)(7) · Forklifts and other powered industrial trucks |
Other-than-serious | $0 | $0 | May 28, 2003 | Closed |
| Citation 2, item 4 29 CFR 1910.303(f) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | May 28, 2003 | Closed |
| Citation 2, item 5a 29 CFR 1910.1200(e)(1) · Hazard communication |
Other-than-serious | $0 | $0 | May 28, 2003 | Closed |
| Citation 2, item 5b 29 CFR 1910.1200(h) · Hazard communication |
Other-than-serious | $0 | $0 | May 28, 2003 | Closed |
188 Candlewood Road, Bay Shore, NY 11706 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
188 Candlewood Road, Bay Shore, NY 11706 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
188 Candlewood Road, Bay Shore, NY 11706 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.212(a)(4) · Machine guarding |
Serious | $100 | $100 | Mar 23, 1987 | Closed |
| Citation 2, item 1 29 CFR 1910.1200(e)(1) · Hazard communication |
Other-than-serious | $0 | $0 | Mar 23, 1987 | Closed |
| Citation 2, item 2 29 CFR 1910.1200(g)(8) · Hazard communication |
Other-than-serious | $0 | $0 | Mar 23, 1987 | Closed |
| Citation 2, item 3 29 CFR 1910.1200(h) · Hazard communication |
Other-than-serious | $0 | $0 | Mar 23, 1987 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.110(e)(4)(iii)
(iii) Permanent and removable fuel containers shall be securely mounted to prevent jarring loose, slipping, or rotating, and the fastenings shall be designed and constructed to withstand static loading in any direction equal to twice the weight of the tank and attachments when filled with fuel using a safety factor of not less than four based on the ultimate strength of the material to be used. Field welding, when necessary, shall be made only on saddle plates, lugs or brackets, originally attached to the container by the tank manufacturer.
29 CFR 1910.1200(e)(1)
(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:
29 CFR 1910.1200(g)(8)
(8) The employer shall maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and shall ensure that they are readily accessible during each work shift to employees when they are in their work area(s). (Electronic access and other alternatives to maintaining paper copies of the safety data sheets are permitted as long as no barriers to immediate employee access in each workplace are created by such options.)
Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.