OSHA SearchOSHA records by employer

Colt Services, LP: OSHA inspections and violations

Jewett, Texas · Support Activities for Oil and Gas Operations · NAICS 213112

2inspections
2citation items
$9,486current penalties
Dec 23, 2021last inspection

OSHA has inspected Colt Services, LP 2 times in Texas since 1991.

The latest one began on Dec 23, 2021 on a referral, in Baytown.

Those inspections ended with 2 citation items: 2 other-than-serious.

Penalties were first proposed at $9,486 and still stand at $9,486.

How that compares: the median penalty per cited inspection for mining and oil and gas employers since 2015 is $2,880, and Colt Services, LP averages $9,136 (1 cited inspection).

1 inspection on this page followed a fatal incident.

It reported 1 severe injury to OSHA since 2015.

Colt Services, LP: OSHA citation items per year, 1991 to 2021
Citation items per year, by inspection date.

Want to know if OSHA cites Colt Services, LP again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 345703466 OPENED DEC 23, 2021Closed

Referral · Partial · Safety · 2 employees at the site · Closed Aug 5, 2022

3525 Decker Dr., Baytown, TX 77520 · Support Activities for Oil and Gas Operations · OSHA's record · Phone and website on Google Maps

Incident on Dec 23, 2021: Employee suffers burns and fracture in explosion at refinery

An employee was working for a contractor that supported gas and oil operations. On or before December 21, 2021, a leak was found on a flange for a bypass line on the Hydro Desulfurization Unit (HDU-1) at refinery operated by an international oil company. The leak was detected because the leak had auto ignited. The refinery owner's fire team had been called out to put the fire out. After the fire was out, steam lances were continuously directed on the flange due to the potential of another flash fire from the leaking heated naphtha. The refinery's owner hired two contract companies to repair the leaking flange using a method called hot bolting. In this method, one bolt at a time was removed and replaced so that workers could install a wire wrap and seal the leak. The replacement bolts were longer and had injection collars. Workers would do the wire wrap and inject the bolts with a sealant to stop the leak. At 1:00 a.m. on December 23, 2021, an employee was working for the contracting firm that would remove and replace the bolts, while the other contractor assisted. As the employee was waiting for the other contractor, an explosion occurred during the repair. The employee suffered second-degree burns. In addition, he suffered a fractured femur when he was struck by a flying object from the explosion. He was hospitalized. Another worker there was not hospitalized. The employee's supervisors knew that the flange had auto ignited the day before they were called to come and fix the leak. The supervisors did not, though, ensure that employees had upgraded their personal protective equipment (PPE) to reduce the risk of serious injuries should a flash fire reoccur. They did not evaluate the hazards and select and require the use of appropriate PPE using their knowledge of the operating conditions, nor did they use refinery owner's safe work practice requirement of using upgraded PPE when work activity is going to be done in areas with potential flash fire.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.119(h)(3)(iv) · Process safety management
Other-than-serious$9,136$9,136Jun 3, 2022Final

Inspection 107557506 OPENED NOV 13, 1991Closed

Unprogrammed related · Complete · Safety · 2 employees at the site · Closed Feb 20, 1992

Limestone Station, Jewett, TX 75846 · OSHA's record · Phone and website on Google Maps

Incident on Nov 12, 1991 (fatal): Employee killed in fall from cooling tower

An employee was doing underground repair work on a cooling tower. He fell about 10.7 meters through a 1.8-meter-diameter opening into a circulating water pipe. He died of injuries sustained in the fall.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1904.2(a) · Partial exemption for establishments in certain industries
Other-than-serious$350$350Jan 24, 1992Closed

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Dec 23, 2021, Baytown: Hospitalization · fractures and burns · multiple body parts, unspecified

An employee was waiting for a flange repair to be completed. There was a naphtha explosion and the employee suffered burns and a broken femur. See also UPA 1847166

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.2 · Partial exemption for establishments in certain industries

29 CFR 1910.119 · Process safety management

Other support activities for oil and gas operations employers in Texas