OSHA SearchOSHA records by employer

Commercial Interiors Inc.: OSHA inspections and violations

Baltimore, Maryland · Framing Contractors · NAICS 238130

16inspections
37citation items
$15,250current penalties
Jan 15, 2025last inspection

OSHA has inspected Commercial Interiors Inc. 16 times in Maryland since 1995.

The latest one began on Jan 15, 2025 as a planned inspection, in Baltimore.

Those inspections ended with 37 citation items: 20 serious and 17 other-than-serious.

Penalties were first proposed at $21,510 and now stand at $15,250, 29% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 7 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Commercial Interiors Inc. averages $0 (1 cited inspection).

Commercial Interiors Inc.: OSHA citation items per year, 1995 to 2025
Citation items per year, by inspection date.

Maryland · latest 90 days of OSHA records

187employers cited

18 of them in the same industry

Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maryland

Checking a subcontractor, a client or your own company? Watch Commercial Interiors Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347981607 OPENED JAN 15, 2025Closed

Planned · Complete · Safety · 14 employees at the site · Closed Mar 20, 2025

7031 Tradepoint Avenue, Baltimore, MD 21219 · Framing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 344567235 OPENED JAN 15, 2020Closed

Unprogrammed other · Partial · Safety · 9 employees at the site · Closed Jun 9, 2020

9800 Medical Center Dr., Rockville, MD 20850 · Framing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343517215 OPENED OCT 1, 2018Closed

Planned · Complete · Safety · 12 employees at the site · Closed Jun 5, 2024

314 6th Street, Annapolis, MD 21403 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Other-than-serious$0$0Dec 26, 2018Final

Inspection 317689230 OPENED MAY 13, 2014Closed

Planned · Complete · Safety · 50 employees at the site · Closed Aug 13, 2014

525 Russell Street, Baltimore, MD 21230 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Other-than-serious$812$565Jun 16, 2014Closed

Inspection 317586550 OPENED JAN 31, 2014Closed

Planned · Complete · Safety · 4 employees at the site · Closed Sep 2, 2015

3915 Liberty Heights Avenue, Baltimore, MD 21215 · Residential Remodelers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.20(b)(2) · Construction safety programs
Other-than-serious$2,625$1,837Apr 25, 2014Closed
Citation 1, item 1b
29 CFR 1926.21(b)(2) · Construction safety training
Other-than-serious$0$0Apr 25, 2014Closed
Citation 1, item 2
29 CFR 1926.25(a) · Housekeeping
Other-than-serious$1,500$900Apr 25, 2014Closed
Citation 1, item 3
29 CFR 1926.34(c) · Means of egress
Serious$1,875$1,125Apr 25, 2014Closed
Citation 1, item 4
29 CFR 1926.150(a)(1) · Fire protection
Serious$1,125$675Apr 25, 2014Closed
Citation 1, item 5
29 CFR 1926.501(b)(14) · Fall protection in construction
Serious$2,625$1,575Apr 25, 2014Closed
Citation 2, item 1
29 CFR 1926.34(b) · Means of egress
Other-than-serious$750$450Apr 25, 2014Closed
Citation 2, item 2a
29 CFR 1926.501(b)(4)(ii) · Fall protection in construction
Other-than-serious$750$525Apr 25, 2014Closed
Citation 2, item 2b
29 CFR 1926.502(i)(3) · Fall protection systems
Other-than-serious$0$0Apr 25, 2014Closed
Citation 2, item 2c
29 CFR 1926.502(i)(4) · Fall protection systems
Other-than-serious$0$0Apr 25, 2014Closed
Citation 2, item 3
29 CFR 1926.503(b)(1) · Fall protection training in construction
Other-than-serious$375$225Apr 25, 2014Closed

Inspection 316508316 OPENED MAY 23, 2012Closed

Planned · Complete · Safety · 1 employee at the site · Closed Aug 1, 2012

4001 Coastal Highway, Ocean City, MD 21842 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$962$670Jun 18, 2012Closed

Inspection 315360669 OPENED AUG 31, 2011Closed

Planned · Complete · Safety · 4 employees at the site · Closed Dec 28, 2011

1306 South Salisbury Boulevard, Salisbury, MD 21801 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$2,250$2,250Oct 13, 2011Closed
Citation 1, item 1b
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$0$0Oct 13, 2011Closed
Citation 1, item 1c
29 CFR 1926.451(c)(2)(i) · Scaffolds, general requirements
Serious$0$0Oct 13, 2011Closed
Citation 1, item 1d
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Oct 13, 2011Closed
Citation 1, item 1e
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$0$0Oct 13, 2011Closed
Citation 1, item 1f
29 CFR 1926.451(f)(4) · Scaffolds, general requirements
Serious$0$0Oct 13, 2011Closed
Citation 1, item 1g
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$0$0Oct 13, 2011Closed
Citation 1, item 1h
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$0$0Oct 13, 2011Closed
Citation 1, item 1i
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Oct 13, 2011Closed
Citation 1, item 1j
29 CFR 1926.454(b) · Scaffold training
Serious$0$0Oct 13, 2011Closed

Inspection 310690540 OPENED DEC 7, 2006Closed

Planned · Complete · Safety · 81 employees at the site · Closed Apr 2, 2007

800 Aliceanna Street, Baltimore, MD 21202 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Other-than-serious$0$0Jan 10, 2007Closed
8 older inspections

Inspection 310283064 OPENED AUG 21, 2006Closed

Planned · Complete · Safety · 15 employees at the site · Closed Dec 29, 2006

Field House Drive, College Park, MD 20740 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(b)(2) · Job-site wiring
Other-than-serious$787$0Sep 21, 2006Closed
Citation 2, item 1 Serious$1,350$729Sep 21, 2006Closed

Inspection 306695438 OPENED APR 22, 2004Closed

Planned · Partial · Safety · 7 employees at the site · Closed Apr 27, 2004

Family Lodge, Building 65 Nih, Bethesda, MD 20892 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 306692880 OPENED AUG 19, 2003Closed

Unprogrammed other · Complete · Safety · 10 employees at the site · Closed Sep 29, 2003

Neuroscience Research Center, Nih, Bethesda, MD 20892 · Finish Carpentry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$525$525Aug 28, 2003Closed
Citation 1, item 1b
29 CFR 1926.452(w)(2) · Rules for each type of scaffold
Serious$0$0Aug 28, 2003Closed

Inspection 305585309 OPENED OCT 9, 2002Closed

Complaint · Partial · Health · Local government · 40 employees at the site · Closed Oct 25, 2002

16 Penn St., Baltimore, MD 21201 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 305571747 OPENED AUG 19, 2002Closed

Complaint · Partial · Safety · 30 employees at the site · Closed Oct 22, 2002

500 St. Paul Place, Baltimore, MD 21202 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$1,137$1,137Sep 23, 2002Closed
Citation 2, item 1
29 CFR 1926.501(b)(4)(ii) · Fall protection in construction
Other-than-serious$0$0Sep 23, 2002Closed
Citation 2, item 2
29 CFR 50405 B01
Other-than-serious$0$0Sep 23, 2002Closed
Citation 2, item 3
29 CFR 50406 A01
Other-than-serious$0$0Sep 23, 2002Closed

Inspection 304089444 OPENED MAY 30, 2001Closed

Planned · Complete · Safety · 4 employees at the site · Closed Jul 31, 2001

560 Gorsuch Road, Westminster, MD 21157 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.300(b)(1) · Tools—Hand and Power: general requirements
Serious$1,375$1,375Jul 2, 2001Closed
Citation 2, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$687$687Jul 2, 2001Closed

Inspection 301998332 OPENED MAY 6, 1998Closed

Planned · Complete · Safety · 2 employees at the site · Closed May 6, 1998

Rt. 108, River Hill Club, Clarksville, MD 21029 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 0912.2102

29 CFR 0912.2303

29 CFR 1926.150 · Fire protection

29 CFR 1926.150(a)(1)

(a) General requirements. (1) The employer shall be responsible for the development of a fire protection program to be followed throughout all phases of the construction and demolition work, and he shall provide for the firefighting equipment as specified in this subpart. As fire hazards occur, there shall be no delay in providing the necessary equipment.

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.20(b)(2)

(2) Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.

29 CFR 1926.21 · Construction safety training

29 CFR 1926.21(b)(2)

(2) The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.

29 CFR 1926.25 · Housekeeping

29 CFR 1926.300 · Tools—Hand and Power: general requirements

29 CFR 1926.34 · Means of egress

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.503 · Fall protection training in construction

Other framing contractors employers in Maryland

Alert subscribers get notified of each newly cited employer in Maryland the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.