OSHA SearchOSHA records by employer

Commonwealth Wood Preservers: OSHA inspections and violations

Hampton, Virginia · Wood Preservation · NAICS 321114

7inspections
38citation items
$6,762current penalties
Apr 8, 2015last inspection

Since 1986, OSHA inspectors have visited Commonwealth Wood Preservers in Virginia 7 times.

The most recent inspection opened on Apr 8, 2015 on a referral, in Hampton.

In all, OSHA issued 38 citation items: 22 serious and 16 other-than-serious.

The proposed penalties came to $12,490; today they stand at $6,762, 46% less.

The rule cited most here is 1910.178 (forklifts and other powered industrial trucks), 6 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,500 penalty. Commonwealth Wood Preservers averages $2,450 across 1 cited inspection.

Commonwealth Wood Preservers: OSHA citation items per year, 1986 to 2015
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

250employers cited

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch Commonwealth Wood Preservers and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340528538 OPENED APR 8, 2015Closed

Referral · Partial · Safety · 20 employees at the site · Closed Aug 21, 2015

5604 City Line Road, Hampton, VA 23661 · Lumber, Plywood, Millwork, and Wood Panel Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 16VAC25-60-120
Serious$3,500$2,450Jul 16, 2015Final
Citation 1, item 1b
29 CFR 1910.147(c)(7)(i)(b) · Lockout/tagout
Serious$3,500$0Jul 16, 2015Final

Inspection 311768808 OPENED JAN 7, 2008Closed

Referral · Partial · Safety · 56 employees at the site · Closed Jun 3, 2008

5604 City Line Road, Hampton, VA 23661 · Wood Preservation · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(4)(ii) · Lockout/tagout
Serious$700$420Apr 29, 2008Closed
Citation 1, item 1b
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$0$0Apr 29, 2008Closed
Citation 1, item 2
29 CFR 1910.212(a)(1) · Machine guarding
Serious$525$315Apr 29, 2008Closed
Citation 1, item 3
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$875$525Apr 29, 2008Closed

Inspection 311768618 OPENED DEC 13, 2007Closed

Planned · Complete · Health · 100 employees at the site · Closed Jun 12, 2008

5604 City Line Road, Hampton, VA 23661 · Wood Preservation · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(f)(2) · Respiratory protection
Serious$525$525Apr 8, 2008Closed
Citation 1, item 1b
29 CFR 1910.134(g)(1)(iia) · Respiratory protection
Serious$0$0Apr 8, 2008Closed
Citation 1, item 1c
29 CFR 1910.134(l)(1) · Respiratory protection
Serious$0$0Apr 8, 2008Closed
Citation 2, item 1
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Other-than-serious$0$0Apr 8, 2008Closed
Citation 2, item 2
29 CFR 1910.37(b)(2) · Exit routes
Other-than-serious$0$0Apr 8, 2008Closed
Citation 2, item 3
29 CFR 1910.37(b)(6) · Exit routes
Other-than-serious$0$0Apr 8, 2008Closed
Citation 2, item 4
29 CFR 1910.106(d)(3)(i) · Flammable liquids
Other-than-serious$0$0Apr 8, 2008Closed

Inspection 301792446 OPENED AUG 6, 1998Closed

Planned · Complete · Health · 60 employees at the site · Closed Nov 9, 1999

5604 City Line Road, Hampton, VA 23661 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2a
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Serious$675$338Sep 30, 1998Final
Citation 1, item 2b
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Serious$0$0Sep 30, 1998Final
Citation 1, item 2c
29 CFR 1910.157(g)(1) · Portable fire extinguishers
Serious$0$0Sep 30, 1998Final
Citation 2, item 1 Other-than-serious$0$0Sep 30, 1998Final
Citation 2, item 2
29 CFR 1910.120(q)(1) · Hazardous waste operations and emergency response
Other-than-serious$0$0Sep 30, 1998Final
Citation 2, item 3
29 CFR 1910.147(c)(7)(iv) · Lockout/tagout
Other-than-serious$0$0Sep 30, 1998Final

Inspection 112378708 OPENED SEP 15, 1992Closed

Planned · Complete · Safety · 60 employees at the site · Closed Nov 23, 1992

5604 City Line Road, Hampton, VA 23661 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(b) · Machine guarding
Serious$700$700Nov 9, 1992Closed
Citation 1, item 2a
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$700$700Nov 9, 1992Closed
Citation 1, item 2b
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$0$0Nov 9, 1992Closed
Citation 2, item 1
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Nov 9, 1992Closed

Inspection 105711170 OPENED FEB 2, 1989Closed

Referral · Partial · Safety · 50 employees at the site · Closed May 9, 1989

5604 City Line Road, Hampton, VA 23661 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.178(a)(2) · Forklifts and other powered industrial trucks
Serious$490$490Feb 27, 1989Closed
Citation 1, item 1b
29 CFR 1910.178(a)(4) · Forklifts and other powered industrial trucks
Serious$0$0Feb 27, 1989Closed
Citation 1, item 1c
29 CFR 1910.178(m)(8) · Forklifts and other powered industrial trucks
Serious$0$0Feb 27, 1989Closed
Citation 2, item 1
29 CFR ARM001101 F
Other-than-serious$0$0Feb 27, 1989Closed
Citation 2, item 2
29 CFR 1910.178(m)(3) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Feb 27, 1989Closed

Inspection 3318839 OPENED JUN 20, 1986Closed

Planned · Complete · Safety · 73 employees at the site · Closed Oct 8, 1986

5604 City Line Road, Hampton, VA 23661 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.213(h)(1) · Woodworking machinery
Serious$150$150Aug 18, 1986Closed
Citation 1, item 2a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$150$150Aug 18, 1986Closed
Citation 1, item 2b
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Aug 18, 1986Closed
Citation 1, item 2c
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$0$0Aug 18, 1986Closed
Citation 2, item 1
29 CFR 1910.106(d)(3)(ii) · Flammable liquids
Other-than-serious$0$0Aug 18, 1986Closed
Citation 2, item 2
29 CFR 1910.178(a)(4) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Aug 18, 1986Closed
Citation 2, item 3
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Aug 18, 1986Closed
Citation 2, item 4
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Other-than-serious$0$0Aug 18, 1986Closed
Citation 2, item 5
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Other-than-serious$0$0Aug 18, 1986Closed
Citation 2, item 6
29 CFR 1910.215(d)(3) · Grinders and abrasive wheels
Other-than-serious$0$0Aug 18, 1986Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(3)(i)

(3) Design, construction, and capacity of storage cabinets—(i) Maximum capacity. Not more than 60 gallons of Category 1, 2, or 3 flammable liquids, nor more than 120 gallons of Category 4 flammable liquids may be stored in a storage cabinet.

29 CFR 1910.106(d)(3)(ii)

(ii) Fire resistance. Storage cabinets shall be designed and constructed to limit the internal temperature to not more than 325 °F. when subjected to a 10-minute fire test using the standard time-temperature curve as set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969, which is incorporated by reference as specified in § 1910.6. All joints and seams shall remain tight and the door shall remain securely closed during the fire test. Cabinets shall be labeled in conspicuous lettering, “Flammable—Keep Fire Away.”

29 CFR 1910.120 · Hazardous waste operations and emergency response

29 CFR 1910.120(q)(1)

(1) A laminated, dated card or certificate with photo, denoting limitations and level of protection for which the employee is trained should be issued to those students successfully completing a course.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.37 · Exit routes

29 CFR 1910.95 · Noise

Other wood preservation employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.