OSHA SearchOSHA records by employer

Comtec MFG. LLC: OSHA inspections and violations

Saint Marys, Pennsylvania · Powder Metallurgy Part Manufacturing · NAICS 332117

1inspections
5citation items
$11,293current penalties
Jul 9, 2024last inspection

OSHA inspectors have visited Comtec MFG. LLC in Pennsylvania one time.

It opened on Jul 9, 2024 on a referral, in Saint Marys.

In all, OSHA issued 5 citation items: 3 serious and 2 other-than-serious.

The proposed penalties came to $16,133; today they stand at $11,293, 30% less.

The rule cited most here is 1910.147 (lockout/tagout), 3 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Comtec MFG. LLC averages $11,293 across 1 cited inspection.

It reported 1 severe injury to OSHA since 2015.

Comtec MFG. LLC: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Want to know if OSHA cites Comtec MFG. LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 347606519 OPENED JUL 9, 2024Closed

Referral · Partial · Safety · 65 employees at the site · Closed Nov 8, 2024

1012 Delaum Road, Saint Marys, PA 15857 · Powder Metallurgy Part Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$9,680$6,776Sep 26, 2024Final
Citation 1, item 2a
29 CFR 1910.147(c)(4)(ii) · Lockout/tagout
Serious$6,453$4,517Sep 26, 2024Final
Citation 1, item 2b
29 CFR 1910.147(e)(3) · Lockout/tagout
Serious$0$0Sep 26, 2024Final
Citation 2, item 1
29 CFR 1904.29(b)(1) · Injury and illness log
Other-than-serious$0$0Sep 26, 2024Final
Citation 2, item 2
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Other-than-serious$0$0Sep 26, 2024Final

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Jun 19, 2024, Saint Marys: Amputation · amputations, avulsions, enucleations unspecified · other finger(s) n.e.c.

An employee was working on a sizing press. They were putting a part into the sizing press when the machine cycled. The employee sustained an amputation to their right index finger.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.29 · Injury and illness log

29 CFR 1904.29(b)(1)

(b) Implementation—(1) What do I need to do to complete the OSHA 300 Log? You must enter information about your business at the top of the OSHA 300 Log, enter a one or two line description for each recordable injury or illness, and summarize this information on the OSHA 300-A at the end of the year.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(4)(ii)

(ii) The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following:

29 CFR 1910.147(c)(6)(i)

(6) Periodic inspection. (i) The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.

OSH Act Section 5 · General Duty Clause

Other powder metallurgy part manufacturing employers in Pennsylvania

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.