Concrete Masonry LLC: OSHA inspections and violations

Gilbert, South Carolina · Masonry Contractors · NAICS 238140

3inspections
6citation items
$2,000current penalties
Jan 15, 2016last inspection

OSHA has inspected Concrete Masonry LLC 3 times in South Carolina since 2013.

The latest one began on Jan 15, 2016 as a planned inspection, in Columbia.

Those inspections ended with 6 citation items: 6 serious.

Penalties were first proposed at $2,625 and now stand at $2,000, 24% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 4 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Concrete Masonry LLC averages $1,000 (1 cited inspection).

Concrete Masonry LLC: OSHA citation items per year, 2013 to 2016
Citation items per year, by inspection date.

South Carolina · latest 90 days of OSHA records

41employers cited

Get notified the morning OSHA posts each new citation in South Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in South Carolina

Checking a subcontractor, a client or your own company? Watch Concrete Masonry LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341181808 OPENED JAN 15, 2016Closed

Planned · Complete · Safety · 8 employees at the site · Closed May 11, 2016

2600 Barhamville Road, Columbia, SC 29204 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.300(b)(2) · Tools—Hand and Power: general requirements
Serious$375$375Feb 10, 2016Final
Citation 1, item 2
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$625$625Feb 10, 2016Final

Inspection 317494284 OPENED APR 23, 2014Closed

Planned · Complete · Safety · 7 employees at the site · Closed Sep 23, 2014

395 Coachman Drive, Sumter, SC 29150 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 4a
29 CFR 1926.451(c)(1)(ii) · Scaffolds, general requirements
Serious$1,250$625May 29, 2014Closed
Citation 1, item 4b
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0May 29, 2014Closed
Citation 1, item 4c
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$0$0May 29, 2014Closed

Inspection 317004174 OPENED APR 2, 2013Closed

Planned · Partial · Safety · 4 employees at the site · Closed Jan 17, 2014

840 Main St, Gilbert, SC 29054 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$375$375May 7, 2013Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.300 · Tools—Hand and Power: general requirements

29 CFR 1926.300(b)(2)

(2) Belts, gears, shafts, pulleys, sprockets, spindles, drums, fly wheels, chains, or other reciprocating, rotating or moving parts of equipment shall be guarded if such parts are exposed to contact by employees or otherwise create a hazard. Guarding shall meet the requirements as set forth in American National Standards Institute, B15.1-1953 (R1958), Safety Code for Mechanical Power-Transmission Apparatus.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(c)(1)(ii)

(ii) Guys, ties, and braces shall be installed according to the scaffold manufacturer's recommendations or at the closest horizontal member to the 4:1 height and be repeated vertically at locations of horizontal members every 20 feet (6.1 m) or less thereafter for scaffolds 3 feet (0.91 m) wide or less, and every 26 feet (7.9 m) or less thereafter for scaffolds greater than 3 feet (0.91 m) wide. The top guy, tie or brace of completed scaffolds shall be placed no further than the 4:1 height from the top. Such guys, ties and braces shall be installed at each end of the scaffold and at horizontal intervals not to exceed 30 feet (9.1 m) (measured from one end [not both] towards the other).

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.501 · Fall protection in construction

Other masonry contractors employers in South Carolina

Alert subscribers get notified of each newly cited employer in South Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.