Inspection 347724296 OPENED AUG 28, 2024Closed
36 Young Dr, Durham, NH 03824 · All Other Telecommunications · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Rochester, New Hampshire · Wired and Wireless Telecommunications Carriers (except Satellite) · NAICS 517110
Since 2018, OSHA inspectors have visited Consolidated Communications in New Hampshire 3 times.
The most recent inspection opened on Aug 28, 2024 as part of a related case, in Durham.
In all, OSHA issued 5 citation items: 4 serious and 1 other-than-serious.
The proposed penalties came to $25,868; today they stand at $19,401, 25% less.
The rule cited most here is 1926.964 (overhead lines and live-line barehand work), 2 times.
Among media and telecom employers, the typical cited inspection since 2015 ends with a $1,800 penalty. Consolidated Communications averages $19,401 across 1 cited inspection.
Consolidated Communications also files yearly injury logs with OSHA, summarized below.
It reported 1 severe injury to OSHA since 2015.
New Hampshire · latest 90 days of OSHA records
52employers cited
Get notified the morning OSHA posts each new citation in New Hampshire: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in New Hampshire
Checking a subcontractor, a client or your own company? Watch Consolidated Communications and get notified the morning OSHA posts a new citation for it.
Watch this company36 Young Dr, Durham, NH 03824 · All Other Telecommunications · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Mechanic Street, Lebanon, NH 03756 · Highway, Street, and Bridge Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Chamberlain St And Whitehall Rd, Rochester, NH 03867 · Wired and Wireless Telecommunications Carriers (except Satellite) · OSHA's record · Phone and website on Google Maps
Incident on Apr 30, 2018: Employee strikes power line with utility pole and receives e
At 11:00 a.m. on April 30, 2018, an employee was holding a utility pole when it contacted a power line. The employee received an electric shock and was hospitalized.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.950(b)(2)(iii) · Electric Power Transmission and Distribution: general |
Serious | $12,934 | $6,467 | Oct 22, 2018 | Final |
| Citation 1, item 1b 29 CFR 1926.950(b)(2)(iv) · Electric Power Transmission and Distribution: general |
Serious | $0 | $0 | Oct 22, 2018 | Final |
| Citation 1, item 2b 29 CFR 1926.952(a)(2) · Job briefing |
Other-than-serious | $0 | $0 | Oct 22, 2018 | Final |
| Citation 1, item 3a 29 CFR 1926.964(a)(3)(i) · Overhead lines and live-line barehand work |
Serious | $12,934 | $12,934 | Oct 22, 2018 | Final |
| Citation 1, item 3b 29 CFR 1926.964(a)(3)(ii) · Overhead lines and live-line barehand work |
Serious | $0 | $0 | Oct 22, 2018 | Final |
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2019, the Durham site logged 2 recordable injuries or illnesses among about 12 workers: 18.0 per 100 full-time workers, against a median of 0.4 for its industry. Those cases cost 202 days away from work.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| Durham: MCDANIEL DR Durham · 2019 | 12 | 2 | 2 | 18.0 | 0.4 |
| Lebanon: 20 BANK ST Lebanon · 2019 | 10 | 2 | 1 | 22.0 | 0.4 |
Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.
Apr 30, 2018, Rochester: Hospitalization · electrical burns, unspecified · nonclassifiable
An employee was setting a utility pole when it contacted the field phase of an existing three-phase primary conductor. The employee received an electrical shock and burn.
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.950(b)(2)(iii)
(iii) The minimum approach distances specified in this subpart corresponding to the voltages to which the qualified employee will be exposed and the skills and techniques necessary to maintain those distances,
29 CFR 1926.950(b)(2)(iv)
(iv) The proper use of the special precautionary techniques, personal protective equipment, insulating and shielding materials, and insulated tools for working on or near exposed energized parts of electric equipment, and
29 CFR 1926.952(a)(2)
(2) Briefing by the employee in charge. The employer shall ensure that the employee in charge conducts a job briefing that meets paragraphs (b), (c), and (d) of this section with the employees involved before they start each job.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.