OSHA SearchOSHA records by employer

Constantino Acosta: OSHA inspections and violations

Leonardtown, Maryland · Framing Contractors · NAICS 238130

1inspections
10citation items
$2,187current penalties
Jul 29, 2019last inspection

OSHA has inspected Constantino Acosta once in Maryland.

The inspection began on Jul 29, 2019 as a planned inspection, in Leonardtown.

That inspection ended with 10 citation items: 8 serious and 2 other-than-serious.

Penalties were first proposed at $3,900 and now stand at $2,187, 44% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 3 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Constantino Acosta averages $2,187 (1 cited inspection).

Constantino Acosta: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Maryland · latest 90 days of OSHA records

194employers cited

19 of them in the same industry

Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maryland

Checking a subcontractor, a client or your own company? Watch Constantino Acosta and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344187224 OPENED JUL 29, 2019Closed

Planned · Complete · Safety · 5 employees at the site · Closed Jan 11, 2022

41512-41520 Margrove Circle, Leonardtown, MD 20650 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$1,050$567Sep 10, 2019Final
Citation 1, item 2a
29 CFR 1926.451(b)(2)(i) · Scaffolds, general requirements
Serious$1,050$567Sep 10, 2019Final
Citation 1, item 2b
29 CFR 1926.451(b)(5)(ii) · Scaffolds, general requirements
Serious$0$0Sep 10, 2019Final
Citation 1, item 2c
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$0$0Sep 10, 2019Final
Citation 1, item 2d
29 CFR 1926.452(j)(2) · Rules for each type of scaffold
Serious$0$0Sep 10, 2019Final
Citation 1, item 2e
29 CFR 1926.454(c) · Scaffold training
Serious$0$0Sep 10, 2019Final
Citation 1, item 3
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$900$486Sep 10, 2019Final
Citation 1, item 4
29 CFR 1926.1053(b)(4) · Ladders in construction
Serious$900$567Sep 10, 2019Final
Citation 2, item 1
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Other-than-serious$0$0Sep 10, 2019Final
Citation 2, item 2
29 CFR 1926.503(b)(1) · Fall protection training in construction
Other-than-serious$0$0Sep 10, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(4)

(4) Ladders shall be used only for the purpose for which they were designed.

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.20(b)(2)

(2) Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(g)(2)(iv)

(iv) Strain relief. Flexible cords shall be connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other framing contractors employers in Maryland

Alert subscribers get notified of each newly cited employer in Maryland the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.