OSHA SearchOSHA records by employer

Constintan Brumari: OSHA inspections and violations

Russellville, Alabama · All Other Specialty Trade Contractors · NAICS 238990

1inspections
5citation items
$10,230current penalties
Jul 23, 2019last inspection

OSHA has inspected Constintan Brumari once in Alabama.

The inspection began on Jul 23, 2019 after a complaint, in Russellville.

That inspection ended with 5 citation items: 5 serious.

Penalties were first proposed at $10,230 and still stand at $10,230.

Scaffolds, general requirements comes up most often in these citations: 3 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Constintan Brumari averages $10,230 (1 cited inspection).

Constintan Brumari: OSHA citation items per year, 2019 to 2019
Citation items per year, by inspection date.

Alabama · latest 90 days of OSHA records

102employers cited

Get notified the morning OSHA posts each new citation in Alabama: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Alabama

Checking a subcontractor, a client or your own company? Watch Constintan Brumari and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344181722 OPENED JUL 23, 2019Closed

Complaint · Complete · Safety · 5 employees at the site · Closed Mar 31, 2025

13770 Highway 43, Russellville, AL 35653 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.59 · Hazard communication
Serious$2,842$2,842Sep 3, 2019Final
Citation 1, item 2a
29 CFR 1926.451(c)(1)(i) · Scaffolds, general requirements
Serious$3,410$3,410Sep 3, 2019Final
Citation 1, item 2b
29 CFR 1926.451(c)(1)(ii) · Scaffolds, general requirements
Serious$0$0Sep 3, 2019Final
Citation 1, item 3a
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$3,978$3,978Sep 3, 2019Final
Citation 1, item 3b
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Sep 3, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(c)(1)(i)

(i) Guys, ties, and braces shall be installed at locations where horizontal members support both inner and outer legs.

29 CFR 1926.451(c)(1)(ii)

(ii) Guys, ties, and braces shall be installed according to the scaffold manufacturer's recommendations or at the closest horizontal member to the 4:1 height and be repeated vertically at locations of horizontal members every 20 feet (6.1 m) or less thereafter for scaffolds 3 feet (0.91 m) wide or less, and every 26 feet (7.9 m) or less thereafter for scaffolds greater than 3 feet (0.91 m) wide. The top guy, tie or brace of completed scaffolds shall be placed no further than the 4:1 height from the top. Such guys, ties and braces shall be installed at each end of the scaffold and at horizontal intervals not to exceed 30 feet (9.1 m) (measured from one end [not both] towards the other).

29 CFR 1926.451(g)(4)(i)

(i) Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews.

29 CFR 1926.454 · Scaffold training

29 CFR 1926.59 · Hazard communication

Other all other specialty trade contractors employers in Alabama

Alert subscribers get notified of each newly cited employer in Alabama the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.