OSHA SearchOSHA records by employer

Constructive Sheet Metal, Inc.: OSHA inspections and violations

Grand Rapids, Michigan · Sheet Metal Work Manufacturing · NAICS 332322

4inspections
30citation items
$7,250current penalties
Apr 3, 2024last inspection

Since 2014, OSHA inspectors have visited Constructive Sheet Metal, Inc. in Michigan 4 times.

The most recent inspection opened on Apr 3, 2024 as a planned inspection, in Allendale.

In all, OSHA issued 30 citation items: 14 serious and 16 other-than-serious.

The proposed penalties came to $14,500; today they stand at $7,250, 50% less.

The rule cited most here is 1910.147 (lockout/tagout), 3 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Constructive Sheet Metal, Inc. averages $2,417 across 3 cited inspections.

Constructive Sheet Metal, Inc. also files yearly injury logs with OSHA, summarized below.

Constructive Sheet Metal, Inc.: OSHA citation items per year, 2014 to 2024
Citation items per year, by inspection date.

Want to know if OSHA cites Constructive Sheet Metal, Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 347390205 OPENED APR 3, 2024Closed

Planned · Partial · Safety · 26 employees at the site · Closed May 23, 2024

11670 46th Ave, Allendale, MI 49401 · Sheet Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 408.22139(2)
Other-than-serious$3,000$1,500Apr 30, 2024Final
Citation 1, item 1b
29 CFR 408.22109(1)
Other-than-serious$0$0Apr 30, 2024Final
Citation 1, item 2
29 CFR 408.22141(1)
Other-than-serious$600$300Apr 30, 2024Final

Inspection 344920905 OPENED SEP 10, 2020Closed

Planned · Complete · Safety · 27 employees at the site · Closed Nov 20, 2020

11670 46th Ave, Allendale, MI 49401 · Sheet Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.28(b)(1)(i) · Fall protection in general industry
Serious$1,200$600Oct 26, 2020Final
Citation 1, item 2
29 CFR 408.10632(1)
Serious$900$450Oct 26, 2020Final
Citation 1, item 3
29 CFR 408.12042(1)
Serious$1,200$600Oct 26, 2020Final
Citation 1, item 4
29 CFR 408.12635(1)
Serious$1,500$750Oct 26, 2020Final
Citation 1, item 5a
29 CFR 408.14912(1)
Serious$1,200$600Oct 26, 2020Final
Citation 1, item 5b
29 CFR 408.14965(1)
Serious$0$0Oct 26, 2020Final
Citation 1, item 6a
29 CFR 1910.147(c)(7)(i)(a) · Lockout/tagout
Serious$900$450Oct 26, 2020Final
Citation 1, item 6b
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$0$0Oct 26, 2020Final
Citation 2, item 1
29 CFR 408.1014K(1)
Other-than-serious$0$0Oct 26, 2020Final
Citation 2, item 2a
29 CFR 408.12154(1)
Other-than-serious$0$0Oct 26, 2020Final
Citation 2, item 2b
29 CFR 408.12171(1)
Other-than-serious$0$0Oct 26, 2020Final

Inspection 340346899 OPENED FEB 10, 2015Closed

Planned · Complete · Safety · 23 employees at the site · Closed Sep 24, 2015

1415 S Division Ave, Grand Rapids, MI 49507 · Sheet Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 408.10033(4)
Serious$500$250Apr 1, 2015Final
Citation 1, item 2
29 CFR 408.10213(2)
Serious$400$200Apr 1, 2015Final
Citation 1, item 3
29 CFR 408.13312(1)
Serious$2,000$1,000Apr 1, 2015Final
Citation 1, item 4
29 CFR 1910.307(c) · Hazardous (classified) locations
Serious$700$350Apr 1, 2015Final
Citation 1, item 5a
29 CFR 1910.107(e)(9) · Spray painting and finishing
Serious$400$200Apr 1, 2015Final
Citation 1, item 5b
29 CFR 1910.107(e)(3) · Spray painting and finishing
Serious$0$0Apr 1, 2015Final
Citation 2, item 1
29 CFR 408.10036(1)
Other-than-serious$0$0Apr 1, 2015Final
Citation 2, item 2
29 CFR 408.10187(1)
Other-than-serious$0$0Apr 1, 2015Final
Citation 2, item 3
29 CFR 408.11211(1)(D)
Other-than-serious$0$0Apr 1, 2015Final
Citation 2, item 4
29 CFR 408.12042(1)
Other-than-serious$0$0Apr 1, 2015Final
Citation 2, item 5a
29 CFR 1910.303(f)(1) · Electrical equipment, general requirements
Other-than-serious$0$0Apr 1, 2015Final
Citation 2, item 5b
29 CFR 1910.303(g)(1) · Electrical equipment, general requirements
Other-than-serious$0$0Apr 1, 2015Final
Citation 2, item 6
29 CFR 408.14965(1)
Other-than-serious$0$0Apr 1, 2015Final
Citation 2, item 7
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Other-than-serious$0$0Apr 1, 2015Final
Citation 2, item 8
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Apr 1, 2015Final

Inspection 315397893 OPENED JUN 23, 2014Closed

Planned · Partial · Safety · 23 employees at the site · Closed Sep 9, 2014

1415 S Division Ave, Grand Rapids, MI 49507 · Sheet Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Other-than-serious$0$0Aug 13, 2014Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Allendale site logged 1 recordable injury or illness among about 25 workers: 4.0 per 100 full-time workers, against a median of 3.6 for its industry. Those cases cost 28 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
CSM
Allendale · 2025
25 114.03.6
Constructive Sheet Metal
Allendale · 2018
31 226.53.6

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(e)(3)

(3) Containers. Original closed containers, approved portable tanks, approved safety cans or a properly arranged system of piping shall be used for bringing flammable liquids or liquids with a flashpoint greater than 199.4 °F (93 °C) into spray finishing room. Open or glass containers shall not be used.

29 CFR 1910.107(e)(9)

(9) Grounding. Whenever flammable liquids or liquids with a flashpoint greater than 199.4 °F (93 °C) are transferred from one container to another, both containers shall be effectively bonded and grounded to prevent discharge sparks of static electricity.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.28 · Fall protection in general industry

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.307 · Hazardous (classified) locations

29 CFR 4082.2129

Other sheet metal work manufacturing employers in Michigan

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.