OSHA SearchOSHA records by employer

Construx, Inc.: OSHA inspections and violations

Manchester, Vermont · Structural Steel and Precast Concrete Contractors · NAICS 238120

5inspections
4citation items
$5,283current penalties
Jul 11, 2022last inspection

Since 2008, OSHA inspectors have visited Construx, Inc. in Vermont 5 times.

The most recent inspection opened on Jul 11, 2022, in Fair Haven.

In all, OSHA issued 4 citation items: 4 other-than-serious.

The penalties, $5,283 in total, stand where OSHA first set them.

The rule cited most here is 1926.404 (ground-fault protection on job sites), 2 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,079 penalty. Construx, Inc. averages $5,283 across 1 cited inspection.

Construx, Inc.: OSHA citation items per year, 2008 to 2022
Citation items per year, by inspection date.

Want to know if OSHA cites Construx, Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 346071236 OPENED JUL 11, 2022Closed

Unprogrammed other · Partial · Safety · 25 employees at the site · Closed Aug 25, 2023

33 Mechanic St., Fair Haven, VT 05743 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites
Unclassified$2,797$2,797Sep 21, 2022Final
Citation 1, item 2a
29 CFR 1926.416(e)(1) · Electrical safety in construction
Unclassified$2,486$2,486Sep 21, 2022Final
Citation 1, item 2b
29 CFR 1926.404(b)(1)(iii)(c) · Ground-fault protection on job sites
Unclassified$0$0Sep 21, 2022Final
Citation 2, item 1
29 CFR 1926.405(g)(1)(iii) · Job-site wiring
Other-than-serious$0$0Sep 21, 2022Final

Inspection 344459557 OPENED OCT 29, 2019Closed

Planned · Partial · Safety · 12 employees at the site · Closed Dec 27, 2019

153 Stafford Ave, Morrisville, VT 05661 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341716447 OPENED AUG 9, 2016Closed

Unprogrammed other · Partial · Safety · 26 employees at the site · Closed Aug 30, 2016

176 Alpine Lane, West Burke, VT 05871 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 340730175 OPENED JUN 24, 2015Closed

Unprogrammed other · Partial · Safety · 25 employees at the site · Closed Aug 3, 2015

220 Bell Rd., Grafton, VT 05146 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 311477228 OPENED MAY 30, 2008Closed

Programmed other · Partial · Safety · 33 employees at the site · Closed Aug 6, 2008

3429 - 3505, Manchester, VT 05254 · Industrial Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(i)

(b) Branch circuits—(1) Ground-fault protection—(i) General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.

29 CFR 1926.404(b)(1)(iii)(c)

(C) Each cord set, attachment cap, plug and receptacle of cord sets, and any equipment connected by cord and plug, except cord sets and receptacles which are fixed and not exposed to damage, shall be visually inspected before each day's use for external defects, such as deformed or missing pins or insulation damage, and for indications of possible internal damage. Equipment found damaged or defective shall not be used until repaired.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(g)(1)(iii)

(iii) Prohibited uses. Unless necessary for a use permitted in paragraph (g)(1)(i) of this section, flexible cords and cables shall not be used:

29 CFR 1926.416 · Electrical safety in construction

Other structural steel and precast concrete contractors employers in Vermont

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.