Since 2015, OSHA inspectors have visited Contech Engineered Solutions, LLC in Alabama 4 times.
The most recent inspection opened on Feb 13, 2025 on a referral, in Montgomery.
In all, OSHA issued 5 citation items: 3 serious and 2 other-than-serious.
The proposed penalties came to $13,220; today they stand at $10,385, 21% less.
The rule cited most here is 1910.147 (lockout/tagout), 3 times.
Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,500 penalty. Contech Engineered Solutions, LLC averages $3,462 across 3 cited inspections.
It reported 2 severe injuries to OSHA since 2015.
Inspection 347110611 OPENED NOV 13, 2023Closed
Planned · Partial · Safety · 49 employees at the site · Closed Apr 22, 2024
2700 Gunter Park Drive West, Montgomery, AL 36109 · Plastics Pipe and Pipe Fitting Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 2 reports on file.
Feb 12, 2025, Montgomery: Amputation · amputations, avulsions, enucleations unspecified · other finger(s) n.e.c.
On February 12, 2025, an employee was performing maintenance on an extruded profile roller. The employee was caught in the powered roller assembly and suffered finger amputations on his left hand.
Oct 23, 2015, Montgomery: Hospitalization · fractures · finger(s), fingernail(s), n.e.c.
An employee was calibrating the corrugator machine when the air cylinder struck his left hand ring finger. The employee was hospitalized for a lacerated and broken finger including the loss of a fingernail.
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.147(c)(4)(ii)(b)
(B) Specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy;
29 CFR 1910.147(c)(4)(ii)(d)
(D) Specific requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control measures.
29 CFR 1910.147(c)(6)(ii)
(ii) The employer shall certify that the periodic inspections have been performed. The certification shall identify the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.