Inspection 347264525 OPENED FEB 7, 2024Closed
W Aqua Ave, Coeur D Alene, ID 83815 · New Housing For-Sale Builders · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Post Falls, Idaho · New Housing For-Sale Builders · NAICS 236117
OSHA has inspected Copper Basin Construction, Inc. 9 times in Idaho since 2003.
The latest one began on Feb 7, 2024 on a referral, in Coeur D Alene.
Those inspections ended with 4 citation items: 3 serious and 1 other-than-serious.
Penalties were first proposed at $3,747 and now stand at $3,487, 7% lower after settlements or reviews.
Fall protection in construction comes up most often in these citations: 2 items under 1926.501.
How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Copper Basin Construction, Inc. averages $607 (1 cited inspection).
Idaho · latest 90 days of OSHA records
62employers cited
Get notified the morning OSHA posts each new citation in Idaho: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Idaho
Checking a subcontractor, a client or your own company? Watch Copper Basin Construction, Inc. and get notified the morning OSHA posts a new citation for it.
Watch this companyW Aqua Ave, Coeur D Alene, ID 83815 · New Housing For-Sale Builders · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
7845 N Ramsey Rd., Coeur D Alene, ID 83815 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Guiness Ln, Post Falls, ID 83854 · New Housing For-Sale Builders · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.405(b)(2) · Job-site wiring |
Serious | $867 | $607 | Apr 12, 2016 | Final |
3052 East Galway Circle, Post Falls, ID 83854 · New Housing For-Sale Builders · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
4295 Sawblade Ln Apartments At Mill River, Coeur D Alene, ID 83814 · New Housing For-Sale Builders · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1926.501(b)(1) · Fall protection in construction |
Serious | $2,380 | $2,380 | Apr 4, 2014 | Final |
| Citation 1, item 1b 29 CFR 1926.502(b)(1) · Fall protection systems |
Serious | $0 | $0 | Apr 4, 2014 | Final |
2068 E. Knapp Cir., Post Falls, ID 83854 · New Housing For-Sale Builders · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
3200 N Huetter Rd, Coeur D'alene, ID 83814 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.501(b)(13) · Fall protection in construction |
Other-than-serious | $500 | $500 | Mar 29, 2006 | Closed |
1214 Forsythia, Sandpoint, ID 83864 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
5067 Building Center Drive, Coeur D'alene, ID 83814 · New Housing For-Sale Builders · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.405(b)(2)
(2) Covers and canopies. All pull boxes, junction boxes, and fittings shall be provided with covers. If metal covers are used, they shall be grounded. In energized installations each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.
29 CFR 1926.501(b)(1)
(b)(1) Unprotected sides and edges. Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.
29 CFR 1926.501(b)(13)
(13) Residential construction. Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of § 1926.502.
Alert subscribers get notified of each newly cited employer in Idaho the morning it is posted. See the alert plans.