OSHA SearchOSHA records by employer

Coreslab Structures, Inc.: OSHA inspections and violations

Albuquerque, New Mexico · Other Concrete Product Manufacturing · NAICS 327390

5inspections
6citation items
$3,300current penalties
May 19, 2016last inspection

Coreslab Structures, Inc. has 5 OSHA inspections on record in New Mexico, the first in 2007.

OSHA's last visit started on May 19, 2016 on a referral, in Albuquerque.

Across those inspections OSHA issued 6 citation items: 3 serious and 3 other-than-serious.

OSHA proposed $3,300 in penalties and the amount has not been reduced.

Most often, OSHA cited 1910.178, forklifts and other powered industrial trucks (2 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. Coreslab Structures, Inc. averages $375 over 1 cited inspection in that time.

Coreslab Structures, Inc.: OSHA citation items per year, 2007 to 2016
Citation items per year, by inspection date.

New Mexico · latest 90 days of OSHA records

35employers cited

Get notified the morning OSHA posts each new citation in New Mexico: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New Mexico

Checking a subcontractor, a client or your own company? Watch Coreslab Structures, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341504017 OPENED MAY 19, 2016Closed

Referral · Complete · Safety · 70 employees at the site · Closed Aug 26, 2016

2800 2nd Street Sw, Albuquerque, NM 87102 · Other Concrete Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Serious$375$375Aug 2, 2016Final
Citation 2, item 1
29 CFR 1910.178(l)(6) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Aug 2, 2016Final
Citation 2, item 2
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Aug 2, 2016Final
Citation 2, item 3
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Other-than-serious$0$0Aug 2, 2016Final

Inspection 317159887 OPENED AUG 8, 2013Closed

Planned · Complete · Safety · 60 employees at the site · Closed Oct 25, 2013

2800 Second St Sw, Albuquerque, NM 87102 · Other Concrete Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.179(j)(3) · Overhead and gantry cranes
Serious$1,625$1,625Sep 25, 2013Closed
Citation 1, item 2
29 CFR 1910.212(a)(1) · Machine guarding
Serious$1,300$1,300Sep 25, 2013Closed

Inspection 313617870 OPENED AUG 25, 2009Closed

Planned · No inspection · Safety · Closed Aug 25, 2009

2800 Second St Sw, Albuquerque, NM 87102 · Other Concrete Product Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 313141533 OPENED MAR 26, 2009Closed

Planned · No inspection · Safety · Closed Apr 20, 2009

2800 Second St Sw, Albuquerque, NM 87102 · Other Concrete Product Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 311570204 OPENED DEC 11, 2007Closed

Planned · No inspection · Safety · Closed Dec 12, 2007

2800 Second St Sw, Albuquerque, NM 87102 · Other Concrete Product Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.178(l)(6)

(6) Certification. The employer shall certify that each operator has been trained and evaluated as required by this paragraph (l). The certification shall include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation.

29 CFR 1910.178(p)(1)

(p) Operation of the truck. (1) If at any time a powered industrial truck is found to be in need of repair, defective, or in any way unsafe, the truck shall be taken out of service until it has been restored to safe operating condition.

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.179(j)(3)

(3) Periodic inspection. Complete inspections of the crane shall be performed at intervals as generally defined in paragraph (j)(1)(ii)(b) of this section, depending upon its activity, severity of service, and environment, or as specifically indicated below. These inspections shall include the requirements of paragraph (j)(2) of this section and in addition, the following items. Any deficiencies such as listed shall be carefully examined and determination made as to whether they constitute a safety hazard:

29 CFR 1910.212 · Machine guarding

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

Other other concrete product manufacturing employers in New Mexico

Alert subscribers get notified of each newly cited employer in New Mexico the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.