Corey Brothers, Inc: OSHA inspections and violations

Charleston, West Virginia · Fresh Fruit and Vegetable Merchant Wholesalers · NAICS 424480

3inspections
31citation items
$4,270current penalties
Aug 11, 2015last inspection

Since 1976, OSHA inspectors have visited Corey Brothers, Inc in West Virginia 3 times.

The most recent inspection opened on Aug 11, 2015 as a planned inspection, in Charleston.

In all, OSHA issued 31 citation items: 16 serious and 15 other-than-serious.

The proposed penalties came to $13,660; today they stand at $4,270, 69% less.

The rule cited most here is 1910.305 (electrical wiring methods), 5 times.

Among wholesale employers, the typical cited inspection since 2015 ends with a $3,423 penalty. Corey Brothers, Inc averages $1,540 across 1 cited inspection.

Corey Brothers, Inc: OSHA citation items per year, 1976 to 2015
Citation items per year, by inspection date.

West Virginia · latest 90 days of OSHA records

28employers cited

Get notified the morning OSHA posts each new citation in West Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in West Virginia

Checking a subcontractor, a client or your own company? Watch Corey Brothers, Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340838952 OPENED AUG 11, 2015Closed

Planned · Complete · Safety · 37 employees at the site · Closed Sep 21, 2015

1410 Lewis St., Charleston, WV 25301 · Fresh Fruit and Vegetable Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.151(c) · First aid and eyewash
Serious$2,380$1,540Sep 10, 2015Final
Citation 2, item 1
29 CFR 1910.157(e)(3) · Portable fire extinguishers
Other-than-serious$0$0Sep 10, 2015Final
Citation 2, item 2
29 CFR 1910.305(j)(1)(i) · Electrical wiring methods
Other-than-serious$0$0Sep 10, 2015Final

Inspection 116223298 OPENED AUG 19, 1999Closed

Planned · Complete · Safety · 67 employees at the site · Closed Apr 20, 2001

1410 Lewis Street, Charleston, WV 25301 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods
Serious$1,000$400Oct 15, 1999Final
Citation 1, item 1b
29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods
Serious$0$0Oct 15, 1999Final
Citation 1, item 1c
29 CFR 1910.305(b)(1) · Electrical wiring methods
Serious$0$0Oct 15, 1999Final
Citation 1, item 1d
29 CFR 1910.303(f) · Electrical equipment, general requirements
Serious$0$0Oct 15, 1999Final
Citation 1, item 2a
29 CFR 1910.305(j)(1)(i) · Electrical wiring methods
Serious$1,250$400Oct 15, 1999Final
Citation 1, item 2b
29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements
Serious$0$0Oct 15, 1999Final
Citation 1, item 3
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Other-than-serious$1,750$0Oct 15, 1999Final
Citation 1, item 4
29 CFR 1910.157(c)(4) · Portable fire extinguishers
Serious$750$400Oct 15, 1999Final
Citation 1, item 5
29 CFR 1910.212(a)(1) · Machine guarding
Serious$1,250$400Oct 15, 1999Final
Citation 1, item 6
29 CFR 1910.22(a)(1) · General requirements
Serious$750$300Oct 15, 1999Final
Citation 1, item 7a Serious$1,000$300Oct 15, 1999Final
Citation 1, item 7b Serious$0$0Oct 15, 1999Final
Citation 1, item 7c Serious$0$0Oct 15, 1999Final
Citation 1, item 8a
29 CFR 1910.134(c)(1) · Respiratory protection
Other-than-serious$1,750$0Oct 15, 1999Final
Citation 1, item 8b
29 CFR 1910.134(h)(1) · Respiratory protection
Serious$0$0Oct 15, 1999Final
Citation 1, item 8c
29 CFR 1910.134(k)(1) · Respiratory protection
Serious$0$0Oct 15, 1999Final
Citation 1, item 9
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$1,750$500Oct 15, 1999Final
Citation 2, item 1
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$0$0Oct 15, 1999Final
Citation 2, item 2
29 CFR 1910.132(f)(4) · Personal protective equipment, general requirements
Other-than-serious$0$0Oct 15, 1999Final
Citation 2, item 3
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Oct 15, 1999Final

Inspection 12326021 OPENED JAN 14, 1976Closed

Planned · Partial · Safety · 35 employees at the site · Closed Mar 5, 1976

1410 Lewis Street East, Charleston, WV 25301 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1904.2 · Partial exemption for establishments in certain industries
Other-than-serious$0$0Jan 21, 1976Closed
Citation 1, item 2
29 CFR 1910.106(g)(8) · Flammable liquids
Other-than-serious$0$0Jan 21, 1976Closed
Citation 1, item 3
29 CFR 1910.157(a)(5) · Portable fire extinguishers
Other-than-serious$0$0Jan 21, 1976Closed
Citation 1, item 4
29 CFR 1910.157(d)(3)(i) · Portable fire extinguishers
Other-than-serious$0$0Jan 21, 1976Closed
Citation 1, item 5
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Other-than-serious$0$0Jan 21, 1976Closed
Citation 1, item 6
29 CFR 1910.252(a)(2)(ivc) · Welding fire safety
Other-than-serious$30$30Jan 21, 1976Closed
Citation 1, item 7
29 CFR 1910.252(a)(2)(vb)(7) · Welding fire safety
Other-than-serious$0$0Jan 21, 1976Closed
Citation 1, item 8 Other-than-serious$0$0Jan 21, 1976Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.2 · Partial exemption for establishments in certain industries

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(g)(8)

(8) Sources of ignition. In addition to the previous restrictions of this paragraph, the following shall apply: There shall be no smoking or open flames in the areas used for fueling, servicing fuel systems for internal combustion engines, receiving or dispensing of flammable liquids. Conspicuous and legible signs prohibiting smoking shall be posted within sight of the customer being served. The motors of all equipment being fueled shall be shut off during the fueling operation.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.132(d)(2)

(2) The employer shall verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and, which identifies the document as a certification of hazard assessment.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.184 · Slings

29 CFR 1910.212 · Machine guarding

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.22 · General requirements

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.252 · Welding fire safety

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.309

Other fresh fruit and vegetable merchant wholesalers employers in West Virginia

Alert subscribers get notified of each newly cited employer in West Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.