OSHA has inspected Corona's Plastering 4 times in New Mexico since 2010.

The latest one began on Apr 4, 2023 as a planned inspection, in Las Cruces; the case is still open.

Those inspections ended with 7 citation items: 6 serious and 1 other-than-serious.

Penalties were first proposed at $10,961 and still stand at $10,961.

Scaffolds, general requirements comes up most often in these citations: 6 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Corona's Plastering averages $9,911 (1 cited inspection).

Corona's Plastering: OSHA citation items per year, 2010 to 2023
Citation items per year, by inspection date.

Want to know if OSHA cites Corona's Plastering again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 346614175 OPENED APR 4, 2023Open

Planned · Complete · Safety · 5 employees at the site · Open

2035 El Presidio, Las Cruces, NM 88001 · Painting and Wall Covering Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(a)(1) · Scaffolds, general requirements
Serious$2,637$2,637Sep 29, 2023Open
Citation 1, item 2a
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$2,637$2,637Sep 29, 2023Open
Citation 1, item 2b
29 CFR 1926.451(c)(2)(i) · Scaffolds, general requirements
Serious$0$0Sep 29, 2023Open
Citation 1, item 3
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,637$2,637Sep 29, 2023Open
Citation 1, item 4
29 CFR 1926.451(h)(1) · Scaffolds, general requirements
Serious$2,000$2,000Sep 29, 2023Open

Inspection 342066693 OPENED JAN 18, 2017Closed

Unprogrammed related · Partial · Safety · 8 employees at the site · Closed Feb 15, 2017

1040 S. Horseshoe Ct., Las Cruces, NM 88003 · Painting and Wall Covering Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 317080067 OPENED MAR 12, 2013Closed

Unprogrammed other · Complete · Safety · 8 employees at the site · Closed Aug 19, 2013

2775 Roadrunner Drive, Las Cruces, NM 88011 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$1,050$1,050May 1, 2013Final

Inspection 314270232 OPENED FEB 23, 2010Closed

Planned · Complete · Safety · 5 employees at the site · Closed Jul 7, 2010

2775 Roadrunner Drive, Las Cruces, NM 88011 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(g)(2)(iii) · Job-site wiring
Other-than-serious$0$0Apr 21, 2010Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(g)(2)(iii)

(iii) Splices. Flexible cords shall be used only in continuous lengths without splice or tap. Hard service flexible cords No. 12 or larger may be repaired if spliced so that the splice retains the insulation, outer sheath properties, and usage characteristics of the cord being spliced.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(a)(1)

(a) Capacity. (1) Except as provided in paragraphs (a)(2), (a)(3), (a)(4), (a)(5) and (g) of this section, each scaffold and scaffold component shall be capable of supporting, without failure, its own weight and at least 4 times the maximum intended load applied or transmitted to it.

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

Other drywall and insulation contractors employers in New Mexico

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.