OSHA SearchOSHA records by employer

Cosco Inc: OSHA inspections and violations

Honolulu, Hawaii · Other Electronic Parts and Equipment Merchant Wholesalers · NAICS 423690

2inspections
10citation items
$8,675current penalties
Jun 7, 2016last inspection

Since 2006, OSHA inspectors have visited Cosco Inc in Hawaii 2 times.

The most recent inspection opened on Jun 7, 2016 as a planned inspection, in Honolulu.

In all, OSHA issued 10 citation items: 7 serious and 3 other-than-serious.

The penalties, $8,675 in total, stand where OSHA first set them.

The rule cited most here is 1910.305 (electrical wiring methods), 4 times.

Among wholesale employers, the typical cited inspection since 2015 ends with a $3,425 penalty. Cosco Inc averages $8,000 across 1 cited inspection.

Cosco Inc: OSHA citation items per year, 2006 to 2016
Citation items per year, by inspection date.

Hawaii · latest 90 days of OSHA records

65employers cited

Get notified the morning OSHA posts each new citation in Hawaii: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Hawaii

Checking a subcontractor, a client or your own company? Watch Cosco Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341535946 OPENED JUN 7, 2016Closed

Planned · Complete · Health · 18 employees at the site · Closed Dec 2, 2016

2312 Kamehameha Hwy #b1, Honolulu, HI 96819 · Warm Air Heating and Air-Conditioning Equipment and Supplies Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.178(a)(4) · Forklifts and other powered industrial trucks
Serious$2,750$2,750Jun 20, 2016Final
Citation 1, item 2
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$1,750$1,750Jun 20, 2016Final
Citation 1, item 3
29 CFR 1910.305(j)(2)(iv) · Electrical wiring methods
Serious$1,750$1,750Jun 20, 2016Final
Citation 1, item 4a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$1,750$1,750Jun 20, 2016Final
Citation 1, item 4b
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$0$0Jun 20, 2016Final

Inspection 310385257 OPENED OCT 3, 2006Closed

Planned · Complete · Safety · 13 employees at the site · Closed Jan 5, 2007

1369 Colburn St, Honolulu, HI 96817 · Other Electronic Parts and Equipment Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$300$300Dec 22, 2006Closed
Citation 1, item 2
29 CFR 1910.304(f)(4) · Grounding and circuit protection
Serious$375$375Dec 22, 2006Closed
Citation 2, item 1
29 CFR 1910.22(d)(1) · General requirements
Other-than-serious$0$0Dec 22, 2006Closed
Citation 2, item 2
29 CFR 1910.305(g)(1)(iiia) · Electrical wiring methods
Other-than-serious$0$0Dec 22, 2006Closed
Citation 2, item 3
29 CFR 1910.305(g)(1)(iiib) · Electrical wiring methods
Other-than-serious$0$0Dec 22, 2006Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.1200(h)(1)

(h) Employee information and training. (1) Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and safety data sheets.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.178(a)(4)

(4) Modifications and additions which affect capacity and safe operation shall not be performed by the customer or user without manufacturers prior written approval. Capacity, operation, and maintenance instruction plates, tags, or decals shall be changed accordingly.

29 CFR 1910.22 · General requirements

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

Other other electronic parts and equipment merchant wholesalers employers in Hawaii

Alert subscribers get notified of each newly cited employer in Hawaii the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.