OSHA SearchOSHA records by employer

Crosswind Aviation Management, LLC: OSHA inspections and violations

Casper, Wyoming · Flight Training · NAICS 611512

1inspections
14citation items
$4,050current penalties
Jun 23, 2015last inspection

OSHA has inspected Crosswind Aviation Management, LLC once in Wyoming.

The inspection began on Jun 23, 2015 after a complaint, in Casper.

That inspection ended with 14 citation items: 9 serious and 5 other-than-serious.

Penalties were first proposed at $7,200 and now stand at $4,050, 44% lower after settlements or reviews.

Spray painting and finishing comes up most often in these citations: 4 items under 1910.107.

How that compares: the median penalty per cited inspection for education employers since 2015 is $0, and Crosswind Aviation Management, LLC averages $4,050 (1 cited inspection).

The Wage and Hour Division has 1 case on it since 2015, with $257 in back wages owed to workers.

Crosswind Aviation Management, LLC: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Wyoming · latest 90 days of OSHA records

31employers cited

Get notified the morning OSHA posts each new citation in Wyoming: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Wyoming

Checking a subcontractor, a client or your own company? Watch Crosswind Aviation Management, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340752104 OPENED JUN 23, 2015Closed

Complaint · Partial · Health · 5 employees at the site · Closed Jul 21, 2017

7956 Fuller Street, Casper, WY 82604 · Flight Training · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Serious$1,800$1,350Dec 7, 2015Final
Citation 1, item 1b
29 CFR 1910.107(b)(9) · Spray painting and finishing
Serious$0$0Dec 7, 2015Final
Citation 1, item 1c
29 CFR 1910.107(b)(10) · Spray painting and finishing
Serious$0$0Dec 7, 2015Final
Citation 1, item 1d
29 CFR 1910.107(d)(5) · Spray painting and finishing
Serious$0$0Dec 7, 2015Final
Citation 1, item 2a
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$1,800$1,350Dec 7, 2015Final
Citation 1, item 2b
29 CFR 1910.134(f)(2) · Respiratory protection
Serious$0$0Dec 7, 2015Final
Citation 1, item 3
29 CFR 1910.212(b) · Machine guarding
Serious$1,800$1,350Dec 7, 2015Final
Citation 1, item 4a
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$1,800$0Dec 7, 2015Final
Citation 1, item 4b
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$0$0Dec 7, 2015Final
Citation 2, item 1
29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements
Other-than-serious$0$0Dec 7, 2015Final
Citation 2, item 2
29 CFR 1910.134(c)(1) · Respiratory protection
Other-than-serious$0$0Dec 7, 2015Final
Citation 2, item 3
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Other-than-serious$0$0Dec 7, 2015Final
Citation 2, item 4a
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Dec 7, 2015Final
Citation 2, item 4b
29 CFR 1910.1200(g)(8) · Hazard communication
Other-than-serious$0$0Dec 7, 2015Final

Wage and hour cases

Cases by the Labor Department's Wage and Hour Division since 2015: unpaid minimum wage or overtime, child labor, family leave and more.

Period reviewedViolationsWorkers owedBack wagesPenalties
Apr 1, 2014 to Jul 11, 2015
Casper
41$257$0

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(10)

(10) Illumination. When spraying areas are illuminated through glass panels or other transparent materials, only fixed lighting units shall be used as a source of illumination. Panels shall effectively isolate the spraying area from the area in which the lighting unit is located, and shall be of a noncombustible material of such a nature or so protected that breakage will be unlikely. Panels shall be so arranged that normal accumulations of residue on the exposed surface of the panel will not be raised to a dangerous temperature by radiation or conduction from the source of illumination.

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.107(b)(9)

(9) Cleaning. Spray booths shall be so installed that all portions are readily accessible for cleaning. A clear space of not less than 3 feet on all sides shall be kept free from storage or combustible construction.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.212 · Machine guarding

29 CFR 1910.215 · Grinders and abrasive wheels

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.