Inspection 343346292 OPENED JUL 31, 2018Closed
125 Grand Ave, Fallon, NV 89406 · Fitness and Recreational Sports Centers · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Crystal Burroughs has 2 OSHA inspections on record in Nevada, the first in 2016.
OSHA's last visit started on Jul 31, 2018 on a referral, in Fallon.
Across those inspections OSHA issued 6 citation items: 1 serious and 5 other-than-serious.
OSHA proposed $600 in penalties and the amount has not been reduced.
Most often, OSHA cited 1910.304, grounding and circuit protection (3 items).
For context, across all arts and recreation employers the median penalty per cited inspection since 2015 is $1,400. Crystal Burroughs averages $600 over 1 cited inspection in that time.
Want to know if OSHA cites Crystal Burroughs again? Add it to a watchlist and we will email you the morning the citation shows up.
Watch this company125 Grand Ave, Fallon, NV 89406 · Fitness and Recreational Sports Centers · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
125 Grand Ave, Fallon, NV 89406 · Fitness and Recreational Sports Centers · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements |
Serious | $600 | $600 | Jun 22, 2016 | Final |
| Citation 2, item 1 29 CFR 1910.303(g)(1) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Jun 22, 2016 | Final |
| Citation 2, item 2 29 CFR 1910.304(a)(2) · Grounding and circuit protection |
Other-than-serious | $0 | $0 | Jun 22, 2016 | Final |
| Citation 2, item 3 29 CFR 1910.304(g)(2) · Grounding and circuit protection |
Other-than-serious | $0 | $0 | Jun 22, 2016 | Final |
| Citation 2, item 4 29 CFR 1910.304(g)(5) · Grounding and circuit protection |
Other-than-serious | $0 | $0 | Jun 22, 2016 | Final |
| Citation 2, item 5 29 CFR 1910.305(b)(2)(i) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Jun 22, 2016 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.303(g)(1)
(1) Space about electric equipment. Sufficient access and working space shall be provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment.
29 CFR 1910.303(g)(2)(i)
(2) Guarding of live parts. (i) Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the following means:
29 CFR 1910.304(a)(2)
(2) Polarity of connections. No grounded conductor may be attached to any terminal or lead so as to reverse designated polarity.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.