OSHA SearchOSHA records by employer

Cummings Construction Corporation: OSHA inspections and violations

Charlotte, North Carolina · Commercial and Institutional Building Construction · NAICS 236220

34inspections
18citation items
$7,675current penalties
Apr 12, 2021last inspection

Since 1996, OSHA inspectors have visited Cummings Construction Corporation in North Carolina 34 times.

The most recent inspection opened on Apr 12, 2021 on a referral, in Concord.

In all, OSHA issued 18 citation items: 9 serious and 9 other-than-serious.

The proposed penalties came to $13,250; today they stand at $7,675, 42% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 7 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Cummings Construction Corporation averages $2,375 across 2 cited inspections.

Cummings Construction Corporation: OSHA citation items per year, 1996 to 2021
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

234employers cited

5 of them in the same industry

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch Cummings Construction Corporation and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345246235 OPENED APR 12, 2021Closed

Referral · Partial · Health · 1 employee at the site · Closed Jun 29, 2021

9975 Poplar Tent Road, Concord, NC 28027 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.20(b)(1) · Construction safety programs
Serious$2,800$2,000Apr 22, 2021Final
Citation 1, item 2
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$2,800$2,000Apr 22, 2021Final

Inspection 341345130 OPENED MAR 21, 2016Closed

Planned · Partial · Health · 3 employees at the site · Closed May 17, 2016

3320/3340 Robinwood Road, Gastonia, NC 28054 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.502(d)(16)(iii) · Fall protection systems
Serious$1,500$750Apr 1, 2016Final

Inspection 316893783 OPENED DEC 28, 2012Closed

Referral · Partial · Safety · 32 employees at the site · Closed Feb 18, 2013

4211 Matthews-indian Trail Road, Matthews, NC 28104 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(c) · Fall protection in construction
Serious$600$600Jan 15, 2013Closed

Inspection 316557180 OPENED MAY 29, 2012Closed

Planned · Partial · Safety · 3 employees at the site · Closed May 31, 2012

5021 Beatties Ford Road, Charlotte, NC 28027 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 316088897 OPENED OCT 5, 2011Closed

Planned · Partial · Safety · 13 employees at the site · Closed Jan 4, 2012

11100 Block Of Hambright Road, Huntersville, NC 28078 · Industrial Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 315443143 OPENED MAR 3, 2011Closed

Planned · Partial · Health · 1 employee at the site · Closed Jul 20, 2011

817 Park Center Drive, Matthews, NC 28105 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Other-than-serious$1,400$500May 26, 2011Closed

Inspection 315129320 OPENED FEB 21, 2011Closed

Complaint · Partial · Safety · 2 employees at the site · Closed Mar 14, 2011

2538 Cuthbertson Rd., Waxhaw, NC 28173 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 315281279 OPENED JAN 27, 2011Closed

Planned · Partial · Safety · 23 employees at the site · Closed Jan 28, 2011

809 - 812 Park Center Drive, Matthews, NC 28105 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

26 older inspections

Inspection 315256172 OPENED JAN 18, 2011Closed

Planned · No inspection · Health · Closed Jan 19, 2011

2529 Beltway Blvd, Charlotte, NC 28214 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 313624892 OPENED JUL 22, 2009Closed

Planned · Partial · Safety · 35 employees at the site · Closed Jul 22, 2009

3221 Stafford Dr., Charlotte, NC 28208 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 311851935 OPENED MAR 3, 2008Closed

Planned · Complete · Safety · 5 employees at the site · Closed May 5, 2008

5335 Prosperity Church Road, Charlotte, NC 28269 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$1,050$600Mar 14, 2008Closed

Inspection 311596373 OPENED OCT 30, 2007Closed

Planned · Partial · Safety · 35 employees at the site · Closed Oct 30, 2007

6801, 6823 South Blvd., Charlotte, NC 28217 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 311385421 OPENED AUG 7, 2007Closed

Referral · Partial · Safety · 35 employees at the site · Closed Aug 15, 2007

6801 South Blvd, Charlotte, NC 28202 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 310984836 OPENED FEB 28, 2007Closed

Planned · Partial · Health · 3 employees at the site · Closed Mar 20, 2007

7325 Smith Corners Blvd., Charlotte, NC 28269 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 309535797 OPENED NOV 4, 2005Closed

Planned · Partial · Safety · 35 employees at the site · Closed Nov 7, 2005

2620 W. Arrowood Rd, Charlotte, NC 28273 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 309535896 OPENED NOV 4, 2005Closed

Planned · Partial · Safety · 2 employees at the site · Closed Jan 9, 2006

10615 Texland Blvd., Charlotte, NC 28273 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(c)(1) · Scaffolds, general requirements
Other-than-serious$750$0Dec 5, 2005Closed
Citation 1, item 2
29 CFR 1926.451(c)(2)(ii) · Scaffolds, general requirements
Serious$750$375Dec 5, 2005Closed

Inspection 309329142 OPENED AUG 15, 2005Closed

Planned · Partial · Safety · 30 employees at the site · Closed Aug 15, 2005

325 E. Woodlawn Rd., Charlotte, NC 28217 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 308367200 OPENED NOV 1, 2004Closed

Planned · Partial · Health · 30 employees at the site · Closed Nov 4, 2004

9424 S. Tryon St, Charlotte, NC 28217 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 308312040 OPENED OCT 11, 2004Closed

Planned · Partial · Health · 30 employees at the site · Closed Nov 5, 2004

9424 S. Tryon St, Charlotte, NC 28217 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.20(b)(2) · Construction safety programs
Other-than-serious$0$0Oct 22, 2004Closed

Inspection 308185404 OPENED SEP 3, 2004Closed

Planned · Partial · Health · 30 employees at the site · Closed Sep 3, 2004

Chestnut Laner & Potter Road, Indian Trail, NC 28079 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 307694703 OPENED APR 15, 2004Closed

Planned · Partial · Safety · 5 employees at the site · Closed Jun 17, 2004

9606 & 9608 Bailey Road, Cornelius, NC 28031 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(14) · Fall protection in construction
Serious$375$375Apr 22, 2004Closed

Inspection 307672022 OPENED MAR 30, 2004Closed

Planned · Partial · Safety · 30 employees at the site · Closed Mar 30, 2004

18500 Starcreek Dr, Cornelius, NC 28031 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 307462622 OPENED FEB 5, 2004Closed

Complaint · Partial · Safety · 5 employees at the site · Closed Feb 5, 2004

Vanburen Dr. (business Park Old Hickory), Indian Trail, NC 28079 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 307441360 OPENED FEB 4, 2004Closed

Complaint · Partial · Health · 4 employees at the site · Closed Apr 19, 2004

9608 Bailey Rd., Cornelius, NC 28301 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$1,000$250Feb 17, 2004Closed
Citation 1, item 1b
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Other-than-serious$0$0Feb 17, 2004Closed
Citation 1, item 2b
29 CFR 1926.20(b)(1) · Construction safety programs
Other-than-serious$0$0Feb 17, 2004Closed
Citation 2, item 1
29 CFR 1926.95(a) · Criteria for personal protective equipment
Other-than-serious$0$0Feb 17, 2004Closed

Inspection 307158113 OPENED NOV 6, 2003Closed

Planned · Partial · Safety · 40 employees at the site · Closed Nov 7, 2003

3825 Wilkinson Blvd., Charlotte, NC 28208 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 306995911 OPENED AUG 20, 2003Closed

Planned · Partial · Health · 2 employees at the site · Closed Aug 20, 2003

1424 Center Park Drive, Charlotte, NC 28217 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 305257255 OPENED APR 3, 2002Closed

Planned · Partial · Safety · 2 employees at the site · Closed Apr 4, 2002

8505 S. Tryon Street, Charlotte, NC 28273 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 304007685 OPENED SEP 25, 2000Closed

Referral · Partial · Safety · 20 employees at the site · Closed Jun 26, 2002

2483 East Franklin Blvd (petro Express), Gastonia, NC 28052 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$100$100Oct 9, 2000Final

Inspection 302232178 OPENED JUL 16, 1998Closed

Planned · No inspection · Safety · Closed Jul 16, 1998

226 W Summit Ave, Charlotte, NC 28217 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 302232152 OPENED JUL 15, 1998Closed

Planned · No inspection · Safety · Closed Jul 16, 1998

6309 Hendry Rd, Charlotte, NC 28216 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 302106398 OPENED MAR 26, 1998Closed

Referral · Partial · Safety · 2 employees at the site · Closed Jun 23, 1998

8505 S. Tryon Street, Charlotte, NC 28273 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Other-than-serious$125$125Apr 24, 1998Closed
Citation 1, item 1b
29 CFR 1926.451(a)(6) · Scaffolds, general requirements
Other-than-serious$0$0Apr 24, 1998Closed

Inspection 301517074 OPENED AUG 28, 1996Closed

Planned · Complete · Safety · 6 employees at the site · Closed Aug 28, 1996

3925 Stuart Andrew Blvd., Charlotte, NC 28217 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 125222331 OPENED MAR 13, 1996Closed

Planned · Complete · Safety · 4 employees at the site · Closed Apr 8, 1996

8438 East Independence Blvd., Charlotte, NC 28227 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1051(a) · Stairways and Ladders: general requirements
Other-than-serious$0$0Mar 29, 1996Closed

Inspection 125223347 OPENED FEB 14, 1996Closed

Planned · Complete · Safety · 10 employees at the site · Closed Feb 14, 1996

1015 Crews Rd, Matthews, NC 28185 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1051 · Stairways and Ladders: general requirements

29 CFR 1926.1051(a)

(a) A stairway or ladder shall be provided at all personnel points of access where there is a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist is provided.

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.20(b)(1)

(b) Accident prevention responsibilities. (1) It shall be the responsibility of the employer to initiate and maintain such programs as may be necessary to comply with this part.

29 CFR 1926.20(b)(2)

(2) Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.95 · Criteria for personal protective equipment

Other commercial and institutional building construction employers in North Carolina

Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.