OSHA SearchOSHA records by employer

Current Electrical Contracting LLC: OSHA inspections and violations

Suffolk, Virginia · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

1inspections
7citation items
$910current penalties
May 22, 2024last inspection

OSHA has inspected Current Electrical Contracting LLC once in Virginia.

The inspection began on May 22, 2024 as a planned inspection, in Suffolk.

That inspection ended with 7 citation items: 7 serious.

Penalties were first proposed at $1,300 and now stand at $910, 30% lower after settlements or reviews.

Job-site wiring comes up most often in these citations: 4 items under 1926.405.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,079, and Current Electrical Contracting LLC averages $910 (1 cited inspection).

Current Electrical Contracting LLC: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Want to know if OSHA cites Current Electrical Contracting LLC again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 347503666 OPENED MAY 22, 2024Closed

Planned · Complete · Safety · 16 employees at the site · Closed Feb 25, 2025

181 N Main St., Suffolk, VA 23434 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.403(d)(1) · Electrical equipment on job sites
Serious$1,300$910Aug 23, 2024Final
Citation 1, item 1b
29 CFR 1926.403(h) · Electrical equipment on job sites
Serious$0$0Aug 23, 2024Final
Citation 1, item 1c
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Serious$0$0Aug 23, 2024Final
Citation 1, item 1d
29 CFR 1926.405(a)(2)(ii)(c) · Job-site wiring
Serious$0$0Aug 23, 2024Final
Citation 1, item 1f
29 CFR 1926.405(a)(2)(ii)(f) · Job-site wiring
Serious$0$0Aug 23, 2024Final
Citation 1, item 1h
29 CFR 1926.405(d) · Job-site wiring
Serious$0$0Aug 23, 2024Final
Citation 1, item 1i Serious$0$0Aug 23, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(d)(1)

(d) Mounting and cooling of equipment—(1) Mounting. Electric equipment shall be firmly secured to the surface on which it is mounted. Wooden plugs driven into holes in masonry, concrete, plaster, or similar materials shall not be used.

29 CFR 1926.403(h)

(h) Identification of disconnecting means and circuits. Each disconnecting means required by this subpart for motors and appliances shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident. These markings shall be of sufficient durability to withstand the environment involved.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.404(b)(1)(ii)

(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.

29 CFR 1926.405 · Job-site wiring

Other electrical contractors and other wiring installation contractors employers in Virginia

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.