OSHA SearchOSHA records by employer

Custom Building and Remodeling, LLC: OSHA inspections and violations

Fargo, North Dakota · New Single-Family Housing Construction (except For-Sale Builders) · NAICS 236115

4inspections
9citation items
$10,620current penalties
Jul 30, 2024last inspection

Custom Building and Remodeling, LLC has 4 OSHA inspections on record in North Dakota, the first in 2014.

OSHA's last visit started on Jul 30, 2024, in Horace.

Across those inspections OSHA issued 9 citation items: 6 serious, 1 repeat and 2 other-than-serious.

OSHA proposed $19,822 in penalties. After settlements and reviews the total is $10,620, down 46%.

Most often, OSHA cited 1926.501, fall protection in construction (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Custom Building and Remodeling, LLC averages $3,207 over 3 cited inspections in that time.

Custom Building and Remodeling, LLC: OSHA citation items per year, 2014 to 2024
Citation items per year, by inspection date.

North Dakota · latest 90 days of OSHA records

30employers cited

Get notified the morning OSHA posts each new citation in North Dakota: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Dakota

Checking a subcontractor, a client or your own company? Watch Custom Building and Remodeling, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347661290 OPENED JUL 30, 2024Closed

Unprogrammed other · Partial · Safety · 4 employees at the site · Closed Apr 1, 2025

7675 Jacks Way, Horace, ND 58047 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.307(d)(1) · Mechanical power-transmission apparatus
Serious$3,547$2,128Jan 21, 2025Final
Citation 1, item 1b
29 CFR 1926.307(e)(3)(i) · Mechanical power-transmission apparatus
Serious$0$0Jan 21, 2025Final
Citation 1, item 2a
29 CFR 1926.451(a)(6) · Scaffolds, general requirements
Serious$3,547$2,128Jan 21, 2025Final
Citation 1, item 2b
29 CFR 1926.451(c)(2)(v) · Scaffolds, general requirements
Serious$0$0Jan 21, 2025Final
Citation 2, item 1
29 CFR 1926.405(b)(2) · Job-site wiring
Other-than-serious$0$0Jan 21, 2025Final
Citation 2, item 2
29 CFR 1926.416(e)(1) · Electrical safety in construction
Other-than-serious$0$0Jan 21, 2025Final

Inspection 343719043 OPENED JAN 15, 2019Closed

Planned · Partial · Safety · 3 employees at the site · Closed Jul 14, 2020

6999 Golden Valley Parkway, Fargo, ND 58104 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Repeat$7,956$3,978Feb 26, 2019Final

Inspection 343630901 OPENED NOV 27, 2018Closed

Planned · Partial · Safety · 4 employees at the site · Closed May 28, 2019

6251 13th Circle South, Fargo, ND 58104 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,772$1,386Dec 20, 2018Final

Inspection 339608432 OPENED FEB 25, 2014Closed

Planned · Partial · Safety · 7 employees at the site · Closed Aug 4, 2014

3640 Bell Boulevard East, West Fargo, ND 58078 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,000$1,000Jun 3, 2014Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.307 · Mechanical power-transmission apparatus

29 CFR 1926.307(d)(1)

(d) Pulleys—(1) Guarding. Pulleys, any parts of which are 7 feet (2.128 m) or less from the floor or working platform, shall be guarded in accordance with the standards specified in paragraphs (m) and (o) of this section. Pulleys serving as balance wheels (e.g., punch presses) on which the point of contact between belt and pulley is more than 6 ft. 6 in. (1.976 m) from the floor or platform may be guarded with a disk covering the spokes.

29 CFR 1926.307(e)(3)(i)

(3) Vertical and inclined belts. (i) Vertical and inclined belts shall be enclosed by a guard conforming to standards in paragraphs (m) and (o) of this section.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(b)(2)

(2) Covers and canopies. All pull boxes, junction boxes, and fittings shall be provided with covers. If metal covers are used, they shall be grounded. In energized installations each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.501 · Fall protection in construction

Other new single-family housing construction (except for-sale builders) employers in North Dakota

Alert subscribers get notified of each newly cited employer in North Dakota the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.