OSHA SearchOSHA records by employer

Custom Steel Service, Inc.: OSHA inspections and violations

Ames, Iowa · Fabricated Structural Metal Manufacturing · NAICS 332312

3inspections
8citation items
$2,872current penalties
Feb 13, 2023last inspection

Since 2012, OSHA inspectors have visited Custom Steel Service, Inc. in Iowa 3 times.

The most recent inspection opened on Feb 13, 2023 as part of a related case, in Ames.

In all, OSHA issued 8 citation items: 7 serious and 1 other-than-serious.

The proposed penalties came to $5,743; today they stand at $2,872, 50% less.

The rule cited most here is 1910.212 (machine guarding), 2 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Custom Steel Service, Inc. averages $622 across 1 cited inspection.

Custom Steel Service, Inc.: OSHA citation items per year, 2012 to 2023
Citation items per year, by inspection date.

Iowa · latest 90 days of OSHA records

59employers cited

Get notified the morning OSHA posts each new citation in Iowa: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Iowa

Checking a subcontractor, a client or your own company? Watch Custom Steel Service, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346504871 OPENED FEB 13, 2023Closed

Unprogrammed related · Partial · Health · 5 employees at the site · Closed Jul 26, 2023

217 High Avenue, Ames, IA 50010 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.1026(d)(1) · Hexavalent chromium
Serious$1,243$622May 4, 2023Final

Inspection 317337228 OPENED SEP 30, 2013Closed

Follow-up · Partial · Safety · 11 employees at the site · Closed Feb 7, 2014

217 High Avenue, Ames, IA 50010 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 316858562 OPENED NOV 26, 2012Closed

Planned · Partial · Safety · 11 employees at the site · Closed Feb 7, 2014

217 High Avenue, Ames, IA 50010 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$750$375Jan 9, 2013Closed
Citation 1, item 2a
29 CFR 1910.178(l)(4)(iii) · Forklifts and other powered industrial trucks
Serious$600$300Jan 9, 2013Closed
Citation 1, item 2b
29 CFR 1910.178(q)(7) · Forklifts and other powered industrial trucks
Serious$0$0Jan 9, 2013Closed
Citation 1, item 3
29 CFR 1910.179(j)(3) · Overhead and gantry cranes
Serious$1,050$525Jan 9, 2013Closed
Citation 1, item 4
29 CFR 1910.212(a)(1) · Machine guarding
Serious$600$300Jan 9, 2013Closed
Citation 1, item 5
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$1,500$750Jan 9, 2013Closed
Citation 2, item 1
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Jan 9, 2013Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1026 · Hexavalent chromium

29 CFR 1910.1026(d)(1)

(d) Exposure determination—(1) General. Each employer who has a workplace or work operation covered by this section shall determine the 8-hour TWA exposure for each employee exposed to chromium (VI). This determination shall be made in accordance with either paragraph (d)(2) or paragraph (d)(3) of this section.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(4)(i)

(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.212 · Machine guarding

Other fabricated structural metal manufacturing employers in Iowa

Alert subscribers get notified of each newly cited employer in Iowa the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.