Cyclone Drilling, Inc: OSHA inspections and violations
Meeker, Colorado · Drilling Oil and Gas Wells · NAICS 213111
11inspections
34citation items
$52,445current penalties
Dec 11, 2018last inspection
Cyclone Drilling, Inc has 11 OSHA inspections on record in Colorado, the first in 2001.
OSHA's last visit started on Dec 11, 2018 on a referral, in Meeker.
Across those inspections OSHA issued 34 citation items: 26 serious and 8 other-than-serious.
OSHA proposed $78,475 in penalties. After settlements and reviews the total is $52,445, down 33%.
Most often, OSHA cited 1910.23, ladders in general industry (10 items).
For context, across all mining and oil and gas employers the median penalty per cited inspection since 2015 is $2,880. Cyclone Drilling, Inc averages $0 over 1 cited inspection in that time.
1 inspection on this page followed a fatal incident.
It reported 1 severe injury to OSHA since 2015.
Citation items per year, by inspection date.
Colorado · latest 90 days of OSHA records
131employers cited
Get notified the morning OSHA posts each new citation in Colorado: the employer, the site address, the rules broken and the penalty.
OSHA records show Cyclone Drilling, Inc at 30 sites in 4 states. Together they've had 71 inspections and $264,679 in current penalties.
We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.
Included with any plan: the site-by-site record for all 30 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.
Incident on Dec 8, 2018: Employee partially amputates finger when caught in chain
At 12:45 p.m. on December 8, 2018, an employee was installing a conductor casing for a surface well and the chains that were being used to hoist the apparatus was not balanced properly. The employee pinched his left hand's index finger between the chain and conductor casing when the chain shifted and partially amputated his finger. Hospitalization was not required.
Incident on Oct 21, 2014 (fatal): Employee is struck by gate valve and is killed
At 7:00 p.m. on October 21, 2014, an employee was re-attaching a 2 inch high pressure flexible fill line hose to the unpressurized side of a gate valve, when the 2 inch gate valve separated from a 2 inch pipe nipple containing 2,800 pounds of drilling fluid . The pressurized gate valve struck the employee in the head and he was killed from his injuries. The pressurized side of the gate valve was 2,800 pounds. This gate valve weighed approximately 70 pounds. The gate valve was manufactured and tested in China to strict National Oilwell Varco (NOV) standards.
Incident on Jan 2, 2003: Employee injured when struck by tong latch
At approximately 7:15 a.m. on January 2, 2003, Employee #1 was working on the ri g platform floor of Rig Number 5. Employee #1 was struck on the head by a tong l atch that slipped off the tong head jaws. Employee #1 suffered multiple head inj uries including skull fractures. Employee #1 was hospitalized.
Incident on Jun 12, 2001: Employee struck and injured from handle of drill
021On June 12, 2001, Employee #1 was repairing a non-functional automatic drill on a Lee C. Moore derrick (Serial Number T2080), while Employee #2 was operating the drawworks that reels in the drill line. Upon completing the adjustment of t he brake linkage between the brake handle and the drawworks, the drawworks start ed to run and draw up the drill line. The startup of the mechanical hoist startl ed Employee #1. Employee #2 tried to gain control of the drawworks but could not . The running drawworks caused the brake handle to swing up towards Employee #1. He tried to shield his face, but the handle of the brake pushed his arm to the side and struck his face. Employee #1 suffered fractures to his face and arm fro m the fierce motion of the brake arm clutched to the drill line. He was hospital ized for orthopedic surgery where medical personnel repaired the injuries sustai ned in the accident as well as for postoperative treatment and care following th e surgery.
An employee was moving a well head blow out preventer (BOP) stack and the chains slipped, amputating approximately 3/8" of the employee's left index finger.
The rules behind these citations
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1904.2 · Partial exemption for establishments in certain industries
(c) Exposure control—(1) Exposure Control Plan. (i) Each employer having an employee(s) with occupational exposure as defined by paragraph (b) of this section shall establish a written Exposure Control Plan designed to eliminate or minimize employee exposure.
(5) Transportation. (i) Chemical manufacturers, importers, or distributors shall ensure that each container of hazardous chemicals leaving the workplace is labeled, tagged, or marked in accordance with this section in a manner which does not conflict with the requirements of the Hazardous Materials Transportation Act (49 U.S.C. 5101 et seq.) and regulations issued under that Act by the Department of Transportation (49 CFR subtitle B).
29 CFR 1910.1200(g)(8)
(8) The employer shall maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and shall ensure that they are readily accessible during each work shift to employees when they are in their work area(s). (Electronic access and other alternatives to maintaining paper copies of the safety data sheets are permitted as long as no barriers to immediate employee access in each workplace are created by such options.)