OSHA SearchOSHA records by employer

D & D Pallet Service: OSHA inspections and violations

Gower, Missouri · Wood Container and Pallet Manufacturing · NAICS 321920

2inspections
9citation items
$7,271current penalties
Feb 1, 2018last inspection

OSHA has inspected D & D Pallet Service 2 times in Missouri since 2010.

The latest one began on Feb 1, 2018 as a planned inspection, in Gower.

Those inspections ended with 9 citation items: 9 serious.

Penalties were first proposed at $13,434 and now stand at $7,271, 46% lower after settlements or reviews.

Electrical equipment, general requirements comes up most often in these citations: 2 items under 1910.303.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,500, and D & D Pallet Service averages $2,771 (1 cited inspection).

D & D Pallet Service: OSHA citation items per year, 2010 to 2018
Citation items per year, by inspection date.

Missouri · latest 90 days of OSHA records

118employers cited

Get notified the morning OSHA posts each new citation in Missouri: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Missouri

Checking a subcontractor, a client or your own company? Watch D & D Pallet Service and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342922069 OPENED FEB 1, 2018Closed

Planned · Complete · Safety · 20 employees at the site · Closed Mar 30, 2018

9230 Nw 316th Street, Gower, MO 64454 · Wood Container and Pallet Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.101(a) · Compressed gases (general requirements)
Serious$2,217$1,219Mar 7, 2018Final
Citation 1, item 2
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Serious$2,217$1,552Mar 7, 2018Final

Inspection 313408320 OPENED FEB 19, 2010Closed

Planned · Complete · Safety · 41 employees at the site · Closed May 6, 2010

9230 Nw 316th Street, Gower, MO 64454 · Wood Container and Pallet Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$1,250$625Apr 22, 2010Closed
Citation 1, item 2
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$2,500$1,250Apr 22, 2010Closed
Citation 1, item 3
29 CFR 1910.157(g)(1) · Portable fire extinguishers
Serious$750$375Apr 22, 2010Closed
Citation 1, item 4
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$1,250$625Apr 22, 2010Closed
Citation 1, item 5
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$1,250$625Apr 22, 2010Closed
Citation 1, item 6
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$1,250$625Apr 22, 2010Closed
Citation 1, item 7
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$750$375Apr 22, 2010Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.101 · Compressed gases (general requirements)

29 CFR 1910.101(a)

(a) Inspection of compressed gas cylinders. Each employer shall determine that compressed gas cylinders under his control are in a safe condition to the extent that this can be determined by visual inspection. Visual and other inspections shall be conducted as prescribed in the Hazardous Materials Regulations of the Department of Transportation (49 CFR parts 171-179 and 14 CFR part 103). Where those regulations are not applicable, visual and other inspections shall be conducted in accordance with Compressed Gas Association Pamphlets C-6-1968 and C-8-1962, which is incorporated by reference as specified in § 1910.6.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(1)

(c) General—(1) Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source, and rendered inoperative.

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.95 · Noise

Other wood container and pallet manufacturing employers in Missouri

Alert subscribers get notified of each newly cited employer in Missouri the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.