OSHA SearchOSHA records by employer

D-L Flange Corporation: OSHA inspections and violations

Houston, Texas · Other Metal Valve and Pipe Fitting Manufacturing · NAICS 332919

1inspections
7citation items
$0current penalties
May 23, 2017last inspection

OSHA inspectors have visited D-L Flange Corporation in Texas one time.

It opened on May 23, 2017 as a planned inspection, in Houston.

In all, OSHA issued 7 citation items: 7 other-than-serious.

No penalty came with these citations.

The rule cited most here is 1910.178 (forklifts and other powered industrial trucks), 2 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. D-L Flange Corporation averages $0 across 1 cited inspection.

D-L Flange Corporation: OSHA citation items per year, 2017 to 2017
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

399employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch D-L Flange Corporation and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342347291 OPENED MAY 23, 2017Closed

Planned · Partial · Safety · 20 employees at the site · Closed Nov 9, 2017

7785 E. Little York Rd., Houston, TX 77016 · Other Metal Valve and Pipe Fitting Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Sep 25, 2017Final
Citation 1, item 2
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Sep 25, 2017Final
Citation 1, item 3 Other-than-serious$0$0Sep 25, 2017Final
Citation 1, item 4
29 CFR 1910.212(a)(1) · Machine guarding
Other-than-serious$0$0Sep 25, 2017Final
Citation 1, item 5
29 CFR 1910.219(c)(3) · Belts, pulleys and power-transmission parts
Other-than-serious$0$0Sep 25, 2017Final
Citation 1, item 6
29 CFR 1910.242(b) · Hand and power tools
Other-than-serious$0$0Sep 25, 2017Final
Citation 1, item 7
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Other-than-serious$0$0Sep 25, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.178(l)(1)(i)

(l) Operator training. (1) Safe operation. (i) The employer shall ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l).

29 CFR 1910.178(p)(1)

(p) Operation of the truck. (1) If at any time a powered industrial truck is found to be in need of repair, defective, or in any way unsafe, the truck shall be taken out of service until it has been restored to safe operating condition.

29 CFR 1910.184 · Slings

29 CFR 1910.184(i)(1)

(i) Synthetic web slings—(1) Sling identification. Each sling shall be marked or coded to show the rated capacities for each type of hitch and type of synthetic web material.

29 CFR 1910.212 · Machine guarding

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.305 · Electrical wiring methods

Other other metal valve and pipe fitting manufacturing employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.