OSHA SearchOSHA records by employer

D S Utilities, Inc.: OSHA inspections and violations

Lexington, South Carolina · Water and Sewer Line and Related Structures Construction · NAICS 237110

5inspections
19citation items
$50,525current penalties
Jan 22, 2015last inspection

OSHA has inspected D S Utilities, Inc. 5 times in South Carolina since 2001.

The latest one began on Jan 22, 2015 as a planned inspection, in Columbia.

Those inspections ended with 19 citation items: 18 serious and 1 willful.

Penalties were first proposed at $70,125 and now stand at $50,525, 28% lower after settlements or reviews.

Excavations comes up most often in these citations: 8 items under 1926.651.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and D S Utilities, Inc. averages $46,760 (1 cited inspection).

D S Utilities, Inc.: OSHA citation items per year, 2001 to 2015
Citation items per year, by inspection date.

South Carolina · latest 90 days of OSHA records

41employers cited

Get notified the morning OSHA posts each new citation in South Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in South Carolina

Checking a subcontractor, a client or your own company? Watch D S Utilities, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340200070 OPENED JAN 22, 2015Closed

Planned · Complete · Safety · 4 employees at the site · Closed Jun 23, 2015

Corner Of Lee Rd. And Washington Rd., Columbia, SC 29207 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(4)(ii) · Fall protection in construction
Serious$2,800$1,680May 5, 2015Final
Citation 1, item 2
29 CFR 1926.651(c)(2) · Excavations
Serious$4,900$2,940May 5, 2015Final
Citation 1, item 3
29 CFR 1926.651(j)(2) · Excavations
Serious$4,900$2,940May 5, 2015Final
Citation 2, item 1
29 CFR 1926.652(a)(1) · Trench protection
Willful$56,000$39,200May 5, 2015Final

Inspection 311505309 OPENED OCT 11, 2007Closed

Planned · Partial · Safety · 5 employees at the site · Closed Jan 9, 2008

Farrow & Clemson Rd, Columbia, SC 29229 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 5a
29 CFR 1926.21(b)(2) · Construction safety training
Serious$0$560Nov 16, 2007Closed
Citation 1, item 5b
29 CFR 1926.651(j)(2) · Excavations
Serious$0$0Nov 16, 2007Closed
Citation 1, item 5c
29 CFR 1926.651(k)(1) · Excavations
Serious$0$0Nov 16, 2007Closed
Citation 1, item 5d
29 CFR 1926.652(a)(1) · Trench protection
Serious$0$0Nov 16, 2007Closed

Inspection 309799096 OPENED MAY 16, 2006Closed

Planned · Partial · Safety · 7 employees at the site · Closed Aug 8, 2006

Barr Road & Pisgah Church Road, Lexington, SC 29073 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 7a
29 CFR 1926.21(b)(2) · Construction safety training
Serious$0$1,680Jun 6, 2006Closed
Citation 1, item 7b
29 CFR 1926.100(a) · Hard hats in construction
Serious$0$0Jun 6, 2006Closed
Citation 1, item 7c
29 CFR 1926.651(c)(2) · Excavations
Serious$0$0Jun 6, 2006Closed
Citation 1, item 7d
29 CFR 1926.651(j)(2) · Excavations
Serious$0$0Jun 6, 2006Closed
Citation 1, item 7e
29 CFR 1926.651(k)(1) · Excavations
Serious$0$0Jun 6, 2006Closed
Citation 1, item 7f
29 CFR 1926.652(a)(1) · Trench protection
Serious$0$0Jun 6, 2006Closed

Inspection 303575484 OPENED FEB 23, 2004Closed

Planned · Partial · Safety · 8 employees at the site · Closed Apr 12, 2004

Pond Branch Road, Lexington, SC 29073 · Water and Sewer Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$150$150Mar 16, 2004Closed
Citation 1, item 2 Serious$250$250Mar 16, 2004Closed
Citation 1, item 3
29 CFR 1926.651(k)(1) · Excavations
Serious$250$250Mar 16, 2004Closed
Citation 1, item 4
29 CFR 1926.652(a)(1) · Trench protection
Serious$250$250Mar 16, 2004Closed

Inspection 303561096 OPENED AUG 15, 2001Closed

Planned · Partial · Safety · 5 employees at the site · Closed Oct 9, 2001

Western Lane, Irmo, SC 29063 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.652(a)(1) · Trench protection
Serious$625$625Sep 12, 2001Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.100(a)

(a) Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets.

29 CFR 1926.21 · Construction safety training

29 CFR 1926.21(b)(2)

(2) The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(4)(ii)

(ii) Each employee on a walking/working surface shall be protected from tripping in or stepping into or through holes (including skylights) by covers.

29 CFR 1926.600 · Equipment

29 CFR 1926.651 · Excavations

29 CFR 1926.652 · Trench protection

Other water and sewer line and related structures construction employers in South Carolina

Alert subscribers get notified of each newly cited employer in South Carolina the morning it is posted. See the alert plans.