OSHA SearchOSHA records by employer

D. W. Burt Concrete Construction, Inc.: OSHA inspections and violations

Ocean City, Maryland · Poured Concrete Foundation and Structure Contractors · NAICS 238110

19inspections
73citation items
$23,795current penalties
Aug 22, 2017last inspection

Since 1984, OSHA inspectors have visited D. W. Burt Concrete Construction, Inc. in Maryland 19 times.

The most recent inspection opened on Aug 22, 2017 on a referral, in Ocean City.

In all, OSHA issued 73 citation items: 32 serious, 2 repeat and 39 other-than-serious.

The proposed penalties came to $47,236; today they stand at $23,795, 50% less.

The rule cited most here is 1926.501 (fall protection in construction), 12 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. D. W. Burt Concrete Construction, Inc. averages $525 across 1 cited inspection.

D. W. Burt Concrete Construction, Inc.: OSHA citation items per year, 1984 to 2017
Citation items per year, by inspection date.

Maryland · latest 90 days of OSHA records

182employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maryland

Checking a subcontractor, a client or your own company? Watch D. W. Burt Concrete Construction, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342242492 OPENED AUG 22, 2017Closed

Referral · Partial · Safety · 5 employees at the site · Closed Nov 9, 2017

208 N. Baltimore Avenue, Ocean City, MD 21842 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341471423 OPENED MAY 11, 2016Closed

Planned · Partial · Safety · 11 employees at the site · Closed May 22, 2017

2500 Baltimore Avenue, Ocean City, MD 21842 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$1,050$525Sep 15, 2016Final
Citation 2, item 1
29 CFR 1926.1051(a) · Stairways and Ladders: general requirements
Other-than-serious$0$0Sep 15, 2016Final

Inspection 341322626 OPENED MAR 14, 2016Closed

Fatality or catastrophe · Partial · Safety · 20 employees at the site · Closed Jun 15, 2016

2501 Philadelphia Avenue, Ocean City, MD 21842 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 315975953 OPENED OCT 3, 2011Closed

Planned · Complete · Safety · 14 employees at the site · Closed Jun 13, 2012

1111 Edgewater Street, Ocean City, MD 21842 · New Multifamily Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 3
29 CFR 1926.501(b)(2)(i) · Fall protection in construction
Serious$2,200$1,900Dec 21, 2011Final
Citation 1, item 4
29 CFR 1926.501(b)(2)(ii) · Fall protection in construction
Serious$1,650$0Dec 21, 2011Final
Citation 1, item 5
29 CFR 1926.1052(c)(1)(ii) · Stairways in construction
Serious$1,925$1,650Dec 21, 2011Final
Citation 1, item 6
29 CFR 1926.1052(b)(3) · Stairways in construction
Serious$1,925$0Dec 21, 2011Final
Citation 2, item 1
29 CFR 1910.178(l)(6) · Forklifts and other powered industrial trucks
Other-than-serious$250$120Dec 21, 2011Final
Citation 2, item 2
29 CFR 1926.416(e)(1) · Electrical safety in construction
Other-than-serious$275$170Dec 21, 2011Final
Citation 2, item 3
29 CFR 1926.502(b)(1) · Fall protection systems
Other-than-serious$550$363Dec 21, 2011Final
Citation 2, item 4
29 CFR 1926.502(k)(3) · Fall protection systems
Other-than-serious$825$670Dec 21, 2011Final
Citation 2, item 5
29 CFR 1926.502(k)(5) · Fall protection systems
Other-than-serious$825$0Dec 21, 2011Final
Citation 2, item 6
29 CFR 1926.502(k)(6) · Fall protection systems
Other-than-serious$825$0Dec 21, 2011Final
Citation 2, item 7
29 CFR 1926.502(k)(7) · Fall protection systems
Other-than-serious$825$0Dec 21, 2011Final
Citation 2, item 8
29 CFR 1926.502(k)(9) · Fall protection systems
Other-than-serious$825$0Dec 21, 2011Final
Citation 2, item 9
29 CFR 1926.503(b)(1) · Fall protection training in construction
Other-than-serious$275$140Dec 21, 2011Final
Citation 2, item 10
29 CFR 1926.1052(c)(7) · Stairways in construction
Other-than-serious$550$419Dec 21, 2011Final
Citation 2, item 11 Other-than-serious$550$419Dec 21, 2011Final
Citation 2, item 12 Other-than-serious$550$0Dec 21, 2011Final
Citation 2, item 13
29 CFR 50405 B03
Other-than-serious$100$0Dec 21, 2011Final
Citation 2, item 14
29 CFR 50406 A01
Other-than-serious$150$59Dec 21, 2011Final

Inspection 310348859 OPENED OCT 24, 2006Closed

Planned · Complete · Safety · 30 employees at the site · Closed Jan 31, 2007

Belmont Towers, Ocean City, MD 21842 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Repeat$4,200$1,600Dec 21, 2006Closed
Citation 2, item 1
29 CFR 1926.503(b)(1) · Fall protection training in construction
Repeat$1,200$450Dec 21, 2006Closed
Citation 3, item 1
29 CFR 1926.95(a) · Criteria for personal protective equipment
Serious$825$350Dec 21, 2006Closed
Citation 4, item 1a
29 CFR 1926.250(b)(1) · General requirements for storage
Serious$2,200$700Dec 21, 2006Closed
Citation 4, item 1b
29 CFR 1926.501(c)(1) · Fall protection in construction
Serious$0$0Dec 21, 2006Closed
Citation 5, item 1
29 CFR 1926.501(b)(2)(i) · Fall protection in construction
Serious$2,200$375Dec 21, 2006Closed
Citation 5, item 2
29 CFR 1926.501(b)(4)(i) · Fall protection in construction
Serious$825$375Dec 21, 2006Closed
Citation 5, item 3
29 CFR 1926.501(b)(14) · Fall protection in construction
Serious$1,100$450Dec 21, 2006Closed
Citation 6, item 1
29 CFR 1926.403(b)(2) · Electrical equipment on job sites
Other-than-serious$412$200Dec 21, 2006Closed
Citation 6, item 2
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Other-than-serious$275$100Dec 21, 2006Closed
Citation 6, item 3
29 CFR 1926.501(b)(4)(ii) · Fall protection in construction
Other-than-serious$412$200Dec 21, 2006Closed
Citation 6, item 4
29 CFR 1926.1051(a) · Stairways and Ladders: general requirements
Other-than-serious$412$200Dec 21, 2006Closed

Inspection 307580449 OPENED MAY 19, 2004Closed

Accident · Partial · Safety · 40 employees at the site · Closed May 27, 2004

301 14th Street, Ocean City, MD 21842 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Incident on May 19, 2004: Employee injures arm in fall

On May 19, 2004, Employee #1 was removing concrete shores from the underside of a cured concrete floor. He was wearing a personal fall arrest harness equipped w ith a built-in lanyard strap; however he had removed his lanyard attachment from its anchorage point. After losing his balance, he fell over an unprotected side of the third floor to the ground. Employee #1 was hospitalized for a broken rig ht arm.

No citations from this inspection.

Inspection 307385351 OPENED APR 23, 2004Open

Planned · Partial · Safety · 40 employees at the site · Open

301 14th Street, Ocean City, MD 21842 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$1,500$800May 14, 2004Open
Citation 1, item 1b
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$0$0May 14, 2004Open
Citation 1, item 1c
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$0$0May 14, 2004Open
Citation 1, item 1d
29 CFR 1926.454(a) · Scaffold training
Serious$0$0May 18, 2004Open
Citation 2, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$1,500$800May 14, 2004Open
Citation 3, item 1a
29 CFR 1926.501(b)(5) · Fall protection in construction
Serious$1,750$900May 14, 2004Open
Citation 3, item 1b
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$0$0May 14, 2004Open
Citation 3, item 1c
29 CFR 1926.503(b)(1) · Fall protection training in construction
Other-than-serious$0$0May 14, 2004Open
Citation 4, item 1a
29 CFR 1926.1052(c)(1)(ii) · Stairways in construction
Serious$1,750$1,300May 14, 2004Open
Citation 4, item 1b
29 CFR 1926.1052(c)(12) · Stairways in construction
Serious$0$0May 14, 2004Open
Citation 4, item 1c
29 CFR 1926.1060(a) · Ladder and stairway training
Serious$0$0May 14, 2004Open

Inspection 306688920 OPENED MAY 8, 2003Closed

Planned · Complete · Safety · 9 employees at the site · Closed May 12, 2003

303 2nd Street, Ocean City, MD 21842 · Poured Concrete Foundation and Structure Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

11 older inspections

Inspection 304073638 OPENED NOV 28, 2000Closed

Planned · Complete · Safety · 12 employees at the site · Closed Jan 25, 2001

Nassau Hotel, Ocean City, MD 21842 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$525$525Dec 26, 2000Closed
Citation 2, item 1
29 CFR 1926.34(c) · Means of egress
Other-than-serious$0$0Dec 26, 2000Closed

Inspection 304073562 OPENED OCT 11, 2000Closed

Planned · Complete · Safety · 11 employees at the site · Closed Jan 16, 2001

1701 Baltimore Avenue, Ocean City, MD 21842 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.34(c) · Means of egress
Other-than-serious$0$0Nov 6, 2000Closed

Inspection 119591188 OPENED JAN 25, 1995Closed

Planned · Complete · Safety · 6 employees at the site · Closed Mar 3, 1999

Carroll St & Us Rt 13, Salisbury, MD 21801 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.152(a)(1) · Flammable liquids
Serious$1,000$1,000Mar 10, 1995Final
Citation 2, item 1
29 CFR 1926.350(a)(8) · Gas welding and cutting
Serious$1,750$1,750Mar 10, 1995Final
Citation 2, item 2
29 CFR 1926.350(h) · Gas welding and cutting
Serious$1,500$1,500Mar 10, 1995Final
Citation 2, item 3
29 CFR 1926.351(b)(4) · Arc welding and cutting
Serious$1,500$1,500Mar 10, 1995Final
Citation 3, item 1
29 CFR 1926.405(g)(2)(iii) · Job-site wiring
Other-than-serious$0$0Mar 10, 1995Final
Citation 3, item 2
29 CFR 50405 B03
Other-than-serious$0$0Mar 10, 1995Final

Inspection 104356878 OPENED MAY 30, 1990Closed

Planned · Complete · Safety · 6 employees at the site · Closed Jan 13, 1991

210 Baptist Street, Salisbury, MD 21801 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.701(f)(2) · Concrete and Masonry Construction: general requirements
Serious$1,410$635Jun 22, 1990Contested

Inspection 108419391 OPENED NOV 15, 1989Closed

Planned · Complete · Safety · 15 employees at the site · Closed Jan 13, 1995

210 Baptist Street, Salisbury, MD 21801 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.500(d)(1) · Scope, application, and definitions applicable to this subpart
Serious$1,240$600Dec 22, 1989Final
Citation 2, item 1
29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements
Serious$475$250Dec 22, 1989Final
Citation 3, item 1
29 CFR 1926.152(a)(1) · Flammable liquids
Other-than-serious$0$0Dec 22, 1989Final
Citation 3, item 2
29 CFR 1926.703(a)(2) · Requirements for cast-in-place concrete
Other-than-serious$0$0Dec 22, 1989Final

Inspection 104386073 OPENED AUG 19, 1988Closed

Planned · Complete · Safety · 9 employees at the site · Closed Nov 7, 1988

125 Street & Assawoman Road, Ocean City, MD 21842 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.550(a)(5) · [Reserved]
Other-than-serious$0$0Oct 17, 1988Closed
Citation 1, item 2
29 CFR 1926.550(a)(6) · [Reserved]
Other-than-serious$0$0Oct 17, 1988Closed
Citation 1, item 3
29 CFR 1926.550(b)(2) · [Reserved]
Other-than-serious$0$0Oct 17, 1988Closed

Inspection 18841882 OPENED SEP 23, 1987Closed

Planned · Complete · Safety · 11 employees at the site · Closed Nov 4, 1987

Rte. 13 North, Salisbury, MD 21801 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.450(a)(9) · Scope, application and definitions applicable to this subpart
Other-than-serious$0$0Oct 9, 1987Closed
Citation 1, item 2
29 CFR 1926.450(a)(10) · Scope, application and definitions applicable to this subpart
Other-than-serious$0$0Oct 9, 1987Closed
Citation 1, item 3
29 CFR 1926.450(b)(12) · Scope, application and definitions applicable to this subpart
Other-than-serious$0$0Oct 9, 1987Closed
Citation 1, item 4
29 CFR 1926.500(d)(1) · Scope, application, and definitions applicable to this subpart
Other-than-serious$0$0Oct 9, 1987Closed
Citation 1, item 5
29 CFR 890032 K A00001
Other-than-serious$0$0Oct 9, 1987Closed
Citation 1, item 6
29 CFR 890032 M B
Other-than-serious$0$0Oct 9, 1987Closed

Inspection 18820126 OPENED JUL 27, 1987Closed

Planned · Complete · Safety · 18 employees at the site · Closed Mar 8, 1988

2305 Northwood Drive, Salisbury,, MD 21801 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1000(b) · Rollover Protective Structures; Overhead Protection: scope
Other-than-serious$350$0Aug 6, 1987Contested

Inspection 14867774 OPENED NOV 27, 1984Closed

Planned · Complete · Safety · 6 employees at the site · Closed Jan 14, 1985

100 E Carroll St, Salisbury, MD 21801 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.401(c) · [Reserved]
Other-than-serious$0$0Dec 18, 1984Closed
Citation 1, item 2
29 CFR 1926.402(a)(10) · Applicability
Other-than-serious$0$0Dec 18, 1984Closed

Inspection 14867550 OPENED OCT 9, 1984Closed

Planned · Complete · Safety · 9 employees at the site · Closed Jun 5, 1985

54th Street, Ocean City, MD 21842 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.500(b)(1) · Scope, application, and definitions applicable to this subpart
Serious$470$470Nov 15, 1984Contested
Citation 1, item 1b
29 CFR 1926.500(f)(5)(ii) · Scope, application, and definitions applicable to this subpart
Serious$0$0Nov 15, 1984Contested
Citation 2, item 1
29 CFR 1926.402(a)(11) · Applicability
Other-than-serious$0$0Nov 15, 1984Closed

Inspection 14835169 OPENED JUN 6, 1984Closed

Planned · Complete · Safety · 2 employees at the site · Closed Aug 2, 1984

3rd St & Ocean, Ocean City, MD 21842 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.350(a)(9) · Gas welding and cutting
Serious$330$330Jul 11, 1984Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.178(l)(6)

(6) Certification. The employer shall certify that each operator has been trained and evaluated as required by this paragraph (l). The certification shall include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation.

29 CFR 1926.1000 · Rollover Protective Structures; Overhead Protection: scope

29 CFR 1926.1000(b)

(b) Equipment manufactured before July 15, 2019. Material handling equipment described in paragraph (a) of this section (excluding compactors and rubber-tired skid-steer equipment) manufactured before July 15, 2019, shall be equipped with rollover protective structures that meet the minimum performance standards prescribed in § 1926.1001(b), as applicable. Agricultural and industrial tractors used in construction shall be equipped with rollover protective structures that meet the minimum performance standards prescribed in § 1926.1002(b), as applicable. When overhead protection is provided on agricultural and industrial tractors, the overhead protection shall meet the minimum performance standards prescribed in § 1926.1003(b), as applicable.

29 CFR 1926.1051 · Stairways and Ladders: general requirements

29 CFR 1926.1051(a)

(a) A stairway or ladder shall be provided at all personnel points of access where there is a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist is provided.

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.1060 · Ladder and stairway training

29 CFR 1926.1412 · Inspections

29 CFR 1926.152 · Flammable liquids

29 CFR 1926.250 · General requirements for storage

29 CFR 1926.34 · Means of egress

29 CFR 1926.350 · Gas welding and cutting

29 CFR 1926.351 · Arc welding and cutting

29 CFR 1926.401 · [Reserved]

29 CFR 1926.402 · Applicability

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.450 · Scope, application and definitions applicable to this subpart

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.454 · Scaffold training

29 CFR 1926.500 · Scope, application, and definitions applicable to this subpart

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.503 · Fall protection training in construction

29 CFR 1926.550 · [Reserved]

29 CFR 1926.701 · Concrete and Masonry Construction: general requirements

29 CFR 1926.703 · Requirements for cast-in-place concrete

29 CFR 1926.95 · Criteria for personal protective equipment

Other poured concrete foundation and structure contractors employers in Maryland

Alert subscribers get notified of each newly cited employer in Maryland the morning it is posted. See the alert plans.