OSHA SearchOSHA records by employer

Dale Tadlock Roofing, Inc.: OSHA inspections and violations

Tallahassee, Florida · Roofing Contractors · NAICS 238160

6inspections
5citation items
$33,810current penalties
Jun 26, 2017last inspection

OSHA has inspected Dale Tadlock Roofing, Inc. 6 times in Florida since 2010.

The latest one began on Jun 26, 2017 as a planned inspection, in Jacksonville.

Those inspections ended with 5 citation items: 4 serious and 1 repeat.

Penalties were first proposed at $69,657 and now stand at $33,810, 51% lower after settlements or reviews.

Fall protection in construction comes up most often in these citations: 3 items under 1926.501.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Dale Tadlock Roofing, Inc. averages $21,510 (1 cited inspection).

Dale Tadlock Roofing, Inc.: OSHA citation items per year, 2010 to 2017
Citation items per year, by inspection date.

Florida · latest 90 days of OSHA records

318employers cited

66 of them in the same industry

Get notified the morning OSHA posts each new citation in Florida: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Florida

Checking a subcontractor, a client or your own company? Watch Dale Tadlock Roofing, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342425790 OPENED JUN 26, 2017Closed

Planned · Complete · Safety · 133 employees at the site · Closed Jul 27, 2017

2045 Taunton Road, Jacksonville, FL 32207 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342090206 OPENED FEB 8, 2017Closed

Planned · Complete · Safety · 118 employees at the site · Closed Aug 4, 2017

2578 Anniston Road, Jacksonville, FL 32246 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.102(a)(1) · Eye and face protection in construction
Serious$10,755$10,755Mar 17, 2017Final
Citation 2, item 1
29 CFR 1926.20(b)(1) · Construction safety programs
Serious$44,817$10,755Mar 17, 2017Final

Inspection 340111939 OPENED DEC 2, 2014Closed

Complaint · Complete · Safety · 60 employees at the site · Closed Feb 4, 2015

4114 Jan Cooley Dr., Panama City, FL 32405 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Repeat$9,800$9,800Dec 12, 2014Final

Inspection 313881682 OPENED FEB 17, 2011Closed

Planned · Complete · Safety · 11 employees at the site · Closed May 18, 2011

2619 W. 23rd Street, Panama City, FL 32405 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$1,785$1,000Feb 25, 2011Closed

Inspection 313878704 OPENED SEP 23, 2010Closed

Planned · Complete · Safety · 11 employees at the site · Closed Sep 24, 2010

3000 North Meridian Rd, Tallahassee, FL 32312 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 313877847 OPENED JUL 13, 2010Closed

Planned · Complete · Safety · 4 employees at the site · Closed Dec 8, 2010

510 West Park Ave., Tallahassee, FL 32305 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$2,500$1,500Sep 14, 2010Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.102 · Eye and face protection in construction

29 CFR 1926.102(a)(1)

(a) General. (1) The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.20(b)(1)

(b) Accident prevention responsibilities. (1) It shall be the responsibility of the employer to initiate and maintain such programs as may be necessary to comply with this part.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.501(b)(10)

(10) Roofing work on Low-slope roofs. Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width (see appendix A to subpart M of this part), the use of a safety monitoring system alone [i.e. without the warning line system] is permitted.

Other roofing contractors employers in Florida

Alert subscribers get notified of each newly cited employer in Florida the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.