OSHA SearchOSHA records by employer

Damian Masonry: OSHA inspections and violations

Mount Pleasant, South Carolina · Masonry Contractors · NAICS 238140

1inspections
4citation items
$4,300current penalties
Dec 9, 2020last inspection

OSHA has inspected Damian Masonry once in South Carolina.

The inspection began on Dec 9, 2020 as a planned inspection, in Mount Pleasant.

That inspection ended with 4 citation items: 4 serious.

Penalties were first proposed at $8,600 and now stand at $4,300, 50% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 3 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Damian Masonry averages $4,300 (1 cited inspection).

Damian Masonry: OSHA citation items per year, 2020 to 2020
Citation items per year, by inspection date.

South Carolina · latest 90 days of OSHA records

43employers cited

Get notified the morning OSHA posts each new citation in South Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in South Carolina

Checking a subcontractor, a client or your own company? Watch Damian Masonry and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345064042 OPENED DEC 9, 2020Closed

Planned · Complete · Safety · 6 employees at the site · Closed Jun 1, 2022

1151 Midtown Ave, Mount Pleasant, SC 29464 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1.12(A)
Serious$1,500$750Mar 9, 2021Final
Citation 1, item 2
29 CFR 1926.451(c)(1)(ii) · Scaffolds, general requirements
Serious$2,800$1,400Mar 9, 2021Final
Citation 1, item 3
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$1,500$750Mar 9, 2021Final
Citation 1, item 4
29 CFR 1926.451(g)(4)(iv) · Scaffolds, general requirements
Serious$2,800$1,400Mar 9, 2021Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(c)(1)(ii)

(ii) Guys, ties, and braces shall be installed according to the scaffold manufacturer's recommendations or at the closest horizontal member to the 4:1 height and be repeated vertically at locations of horizontal members every 20 feet (6.1 m) or less thereafter for scaffolds 3 feet (0.91 m) wide or less, and every 26 feet (7.9 m) or less thereafter for scaffolds greater than 3 feet (0.91 m) wide. The top guy, tie or brace of completed scaffolds shall be placed no further than the 4:1 height from the top. Such guys, ties and braces shall be installed at each end of the scaffold and at horizontal intervals not to exceed 30 feet (9.1 m) (measured from one end [not both] towards the other).

29 CFR 1926.451(f)(3)

(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.

29 CFR 1926.451(g)(4)(iv)

(iv) When midrails are used, they shall be installed at a height approximately midway between the top edge of the guardrail system and the platform surface.