OSHA SearchOSHA records by employer

Damitio Construction, Inc.: OSHA inspections and violations

Tucson, Arizona · Commercial and Institutional Building Construction · NAICS 236220

15inspections
17citation items
$10,700current penalties
Aug 10, 2018last inspection

Damitio Construction, Inc. has 15 OSHA inspections on record in Arizona, the first in 2000.

OSHA's last visit started on Aug 10, 2018 as part of a related case, in Chandler.

Across those inspections OSHA issued 17 citation items: 7 serious, 2 repeat and 8 other-than-serious.

OSHA proposed $10,700 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.1053, ladders in construction (4 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Damitio Construction, Inc. averages $875 over 2 cited inspections in that time.

Damitio Construction, Inc.: OSHA citation items per year, 2000 to 2018
Citation items per year, by inspection date.

Arizona · latest 90 days of OSHA records

92employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Arizona: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Arizona

Checking a subcontractor, a client or your own company? Watch Damitio Construction, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343379723 OPENED AUG 10, 2018Closed

Unprogrammed related · Partial · Safety · 1 employee at the site · Closed Jan 8, 2019

990 N Arizona Ave, Chandler, AZ 85225 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$1,000$1,000Dec 12, 2018Final

Inspection 342663044 OPENED SEP 26, 2017Closed

Complaint · Partial · Safety · 7 employees at the site · Closed Sep 26, 2017

2990 W Valencia, Tucson, AZ 85746 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 340794619 OPENED JUL 15, 2015Closed

Planned · Complete · Health · 1 employee at the site · Closed Oct 14, 2015

545 E Mcdowell Rd, Phoenix, AZ 85004 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(c)(2) · Excavations
Serious$750$750Sep 14, 2015Final

Inspection 317693976 OPENED APR 28, 2014Closed

Planned · Partial · Safety · 1 employee at the site · Closed May 6, 2014

5050 W Indian School Rd, Phoenix, AZ 85031 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 317693612 OPENED APR 16, 2014Closed

Planned · Complete · Safety · 1 employee at the site · Closed Jul 15, 2014

6650 W Van Buren St, Phoenix, AZ 85043 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(c)(2) · Excavations
Other-than-serious$0$0Jun 4, 2014Closed
Citation 1, item 2
29 CFR 1926.652(a)(1) · Trench protection
Other-than-serious$0$0Jun 4, 2014Closed

Inspection 317173433 OPENED JUN 24, 2013Closed

Planned · Partial · Safety · 1 employee at the site · Closed Jun 25, 2013

1059 E Tucson Market Pl, Tucson, AZ 85713 · Industrial Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 316684596 OPENED AUG 29, 2012Closed

Planned · Complete · Safety · 1 employee at the site · Closed Sep 5, 2012

1795 W Ajo Way, Tucson, AZ 85713 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 316343359 OPENED JAN 31, 2012Closed

Planned · Complete · Safety · 1 employee at the site · Closed Mar 12, 2012

8800 E Broadway Blvd, Tucson, AZ 85710 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.20(b)(2) · Construction safety programs
Repeat$200$200Feb 16, 2012Closed
7 older inspections

Inspection 315584607 OPENED MAY 10, 2011Closed

Unprogrammed related · Complete · Safety · 1 employee at the site · Closed Jul 5, 2011

4495 N Oracle Rd, Tucson, AZ 85737 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.20(b)(2) · Construction safety programs
Other-than-serious$0$0Jun 23, 2011Closed
Citation 1, item 2
29 CFR 1926.1051(a) · Stairways and Ladders: general requirements
Other-than-serious$0$0Jun 23, 2011Closed

Inspection 313572943 OPENED JUN 4, 2009Closed

Unprogrammed related · Complete · Safety · 3 employees at the site · Closed Jun 4, 2009

223 N 7th Ave, Phoenix, AZ 85003 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 310697214 OPENED JAN 11, 2007Closed

Unprogrammed other · Partial · Health · 2 employees at the site · Closed Apr 14, 2007

3207 W. Indian School, Phoenix, AZ 85017 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(10) · Fall protection in construction
Repeat$5,000$5,000Mar 6, 2007Closed

Inspection 310163811 OPENED JUN 13, 2006Closed

Planned · Complete · Safety · 8 employees at the site · Closed Dec 29, 2006

8100 S. Houghton Rd., Tucson, AZ 85747 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$1,500$1,500Aug 2, 2006Closed
Citation 1, item 3a
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$1,500$1,500Aug 2, 2006Closed
Citation 1, item 3b
29 CFR 1926.1053(b)(4) · Ladders in construction
Serious$0$0Aug 2, 2006Closed
Citation 1, item 3c
29 CFR 1926.1060(a) · Ladder and stairway training
Serious$0$0Aug 2, 2006Closed

Inspection 310136312 OPENED MAY 24, 2006Closed

Unprogrammed other · Complete · Safety · 1 employee at the site · Closed Oct 3, 2007

1821 E. Broadway, Tucson, AZ 85716 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$750$750Aug 1, 2006Closed
Citation 2, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Other-than-serious$0$0Aug 1, 2006Closed
Citation 2, item 2
29 CFR 1926.1053(a)(1)(i) · Ladders in construction
Other-than-serious$0$0Aug 1, 2006Closed
Citation 2, item 3
29 CFR 1926.1053(b)(1) · Ladders in construction
Other-than-serious$0$0Aug 1, 2006Closed

Inspection 305226854 OPENED FEB 27, 2002Closed

Planned · Partial · Safety · 1 employee at the site · Closed Apr 8, 2002

3232 N. Campbell Ave., Tucson, AZ 85719 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(f)(4) · Scaffolds, general requirements
Other-than-serious$0$0Apr 2, 2002Closed

Inspection 303539860 OPENED MAY 2, 2000Closed

Planned · Partial · Safety · 1 employee at the site · Closed May 16, 2000

3310 East 22nd Street, Tucson, AZ 85713 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1051 · Stairways and Ladders: general requirements

29 CFR 1926.1051(a)

(a) A stairway or ladder shall be provided at all personnel points of access where there is a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist is provided.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(a)(1)(i)

(i) Each self-supporting portable ladder: At least four times the maximum intended load, except that each extra-heavy-duty type 1A metal or plastic ladder shall sustain at least 3.3 times the maximum intended load. The ability of a ladder to sustain the loads indicated in this paragraph shall be determined by applying or transmitting the requisite load to the ladder in a downward vertical direction. Ladders built and tested in conformance with the applicable provisions of appendix A of this subpart will be deemed to meet this requirement.

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.1060 · Ladder and stairway training

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.651 · Excavations

29 CFR 1926.652 · Trench protection

Other commercial and institutional building construction employers in Arizona

Alert subscribers get notified of each newly cited employer in Arizona the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.