OSHA SearchOSHA records by employer

Darrey Machine Inc.: OSHA inspections and violations

Odessa, Texas · Machine Shops · NAICS 332710

1inspections
5citation items
$3,259current penalties
Dec 1, 2016last inspection

Darrey Machine Inc. has one OSHA inspection on record in Texas.

OSHA opened it on Dec 1, 2016 as a planned inspection, in Odessa.

From that inspection OSHA issued 5 citation items: 5 serious.

OSHA proposed $5,432 in penalties. After settlements and reviews the total is $3,259, down 40%.

Most often, OSHA cited 1910.303, electrical equipment, general requirements (3 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Darrey Machine Inc. averages $3,259 over 1 cited inspection in that time.

Darrey Machine Inc.: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Want to know if OSHA cites Darrey Machine Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 341953511 OPENED DEC 1, 2016Closed

Planned · Complete · Safety · 6 employees at the site · Closed Mar 13, 2017

12001 W. Cr 125, Odessa, TX 79765 · Machine Shops · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.179(j)(2)(iv) · Overhead and gantry cranes
Serious$2,173$1,304Feb 15, 2017Final
Citation 1, item 2a
29 CFR 1910.303(b)(1) · Electrical equipment, general requirements
Serious$3,259$1,955Feb 15, 2017Final
Citation 1, item 2b
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$0$0Feb 15, 2017Final
Citation 1, item 2c
29 CFR 1910.303(b)(7)(i) · Electrical equipment, general requirements
Serious$0$0Feb 15, 2017Final
Citation 1, item 2d
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Serious$0$0Feb 15, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.179(j)(2)(iv)

(iv) Hoist chains, including end connections, for excessive wear, twist, distorted links interfering with proper function, or stretch beyond manufacturer's recommendations. Visual inspection daily; monthly inspection with a certification record which includes the date of inspection, the signature of the person who performed the inspection and an identifier of the chain which was inspected.

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(b)(1)

(b) Examination, installation, and use of equipment—(1) Examination. Electric equipment shall be free from recognized hazards that are likely to cause death or serious physical harm to employees. Safety of equipment shall be determined using the following considerations:

29 CFR 1910.303(b)(2)

(2) Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling.

29 CFR 1910.305 · Electrical wiring methods

Other machine shops employers in Texas

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.