Inspection 341284388 OPENED FEB 23, 2016Open
615 N 300 E, Parowan, UT 84761 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection so far.
David Harris Custom Cabinets Inc has 2 OSHA inspections on record in Utah, the first in 2016.
OSHA's last visit started on Feb 23, 2016 after a complaint, in Parowan, and the case has not closed yet.
Across those inspections OSHA issued 9 citation items: 6 serious and 3 other-than-serious.
OSHA proposed $3,150 in penalties. After settlements and reviews the total is $1,575, down 50%.
Most often, OSHA cited 1910.134, respiratory protection (3 items).
For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. David Harris Custom Cabinets Inc averages $1,575 over 1 cited inspection in that time.
Utah · latest 90 days of OSHA records
67employers cited
Get notified the morning OSHA posts each new citation in Utah: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Utah
Checking a subcontractor, a client or your own company? Watch David Harris Custom Cabinets Inc and get notified the morning OSHA posts a new citation for it.
Watch this company615 N 300 E, Parowan, UT 84761 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection so far.
615 N 300 E, Parowan, UT 84761 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.107(c)(6) · Spray painting and finishing |
Serious | $750 | $375 | Apr 14, 2016 | Final |
| Citation 1, item 1b 29 CFR 1910.303(g)(1) · Electrical equipment, general requirements |
Serious | $0 | $0 | Apr 14, 2016 | Final |
| Citation 1, item 1c 29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods |
Serious | $0 | $0 | Apr 14, 2016 | Final |
| Citation 1, item 2a 29 CFR 1910.134(c)(1) · Respiratory protection |
Serious | $1,500 | $750 | Apr 14, 2016 | Final |
| Citation 1, item 2b 29 CFR 1910.134(e)(1) · Respiratory protection |
Serious | $0 | $0 | Apr 14, 2016 | Final |
| Citation 1, item 2c 29 CFR 1910.134(f)(2) · Respiratory protection |
Serious | $0 | $0 | Apr 14, 2016 | Final |
| Citation 2, item 1 29 CFR 1910.22(a)(1) · General requirements |
Other-than-serious | $300 | $150 | Apr 14, 2016 | Final |
| Citation 2, item 2 29 CFR 1910.37(b)(2) · Exit routes |
Other-than-serious | $300 | $150 | Apr 14, 2016 | Final |
| Citation 2, item 3 29 CFR 1910.1200(e)(1) · Hazard communication |
Other-than-serious | $300 | $150 | Apr 14, 2016 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.107(c)(6)
(6) Wiring type approved. Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations.
29 CFR 1910.1200(e)(1)
(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:
29 CFR 1910.134(c)(1)
(1) The test instrument must have an effective audio-warning device, or a visual-warning device in the form of a screen tracing, that indicates when the test subject fails to hold his or her breath during the test. The test must be terminated and restarted from the beginning when the test subject fails to hold his or her breath during the test. The test subject then may be refitted and retested.
Alert subscribers get notified of each newly cited employer in Utah the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.