Davidson Fabricating, Inc.: OSHA inspections and violations

Broomall, Pennsylvania · Other Motor Vehicle Parts Manufacturing · NAICS 336399

5inspections
30citation items
$7,671current penalties
Sep 24, 2024last inspection

Since 1974, OSHA inspectors have visited Davidson Fabricating, Inc. in Pennsylvania 5 times.

The most recent inspection opened on Sep 24, 2024 as a planned inspection, in West Chester.

In all, OSHA issued 30 citation items: 15 serious and 15 other-than-serious.

The proposed penalties came to $9,771; today they stand at $7,671, 21% less.

The rule cited most here is 1910.305 (electrical wiring methods), 4 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Davidson Fabricating, Inc. averages $5,531 across 1 cited inspection.

Davidson Fabricating, Inc.: OSHA citation items per year, 1974 to 2024
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

285employers cited

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Davidson Fabricating, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347774564 OPENED SEP 24, 2024Closed

Planned · Complete · Safety · 20 employees at the site · Closed Mar 18, 2026

11 Hagerty Blvd Po Box 381, West Chester, PA 19382 · Sheet Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$5,531$5,531Jan 10, 2025Final

Inspection 343818324 OPENED FEB 28, 2019Closed

Planned · Partial · Safety · 17 employees at the site · Closed Feb 28, 2019

511 Abbott Drive, Broomall, PA 19008 · Other Motor Vehicle Parts Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 102944345 OPENED FEB 13, 1996Closed

Planned · Complete · Safety · 18 employees at the site · Closed Dec 4, 1997

511 Abbott Drive, Broomall, PA 19008 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes
Serious$750$300Mar 27, 1996Closed
Citation 1, item 2a
29 CFR 1910.106(d)(4)(i) · Flammable liquids
Serious$450$300Mar 27, 1996Closed
Citation 1, item 2b
29 CFR 1910.106(d)(4)(iv) · Flammable liquids
Serious$0$0Mar 27, 1996Closed
Citation 1, item 4
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$600$300Mar 27, 1996Closed
Citation 1, item 5a
29 CFR 1910.212(a)(1) · Machine guarding
Serious$450$300Mar 27, 1996Closed
Citation 1, item 5b
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$0$0Mar 27, 1996Closed
Citation 1, item 6a
29 CFR 1910.217(c)(1)(i) · Mechanical power presses
Serious$750$300Mar 27, 1996Closed
Citation 1, item 6b
29 CFR 1910.217(d)(6)(i) · Mechanical power presses
Serious$0$0Mar 27, 1996Closed
Citation 1, item 6c
29 CFR 1910.217(e)(1)(i) · Mechanical power presses
Serious$0$0Mar 27, 1996Closed
Citation 1, item 7a
29 CFR 1910.219(b)(1) · Belts, pulleys and power-transmission parts
Serious$600$300Mar 27, 1996Closed
Citation 1, item 7b
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$0$0Mar 27, 1996Closed
Citation 1, item 7c
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Mar 27, 1996Closed
Citation 1, item 7d
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Mar 27, 1996Closed
Citation 1, item 8
29 CFR 1910.307(b) · Hazardous (classified) locations
Serious$600$300Mar 27, 1996Closed
Citation 2, item 1
29 CFR 1910.36(d)(1) · Exit route design
Other-than-serious$0$0Mar 27, 1996Closed
Citation 2, item 2
29 CFR 1910.37(q)(1) · Exit routes
Other-than-serious$0$0Mar 27, 1996Closed
Citation 2, item 3
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Other-than-serious$0$0Mar 27, 1996Closed
Citation 2, item 4
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Other-than-serious$0$0Mar 27, 1996Closed
Citation 2, item 5
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Mar 27, 1996Closed
Citation 2, item 6
29 CFR 1910.305(b)(1) · Electrical wiring methods
Other-than-serious$0$0Mar 6, 1996Closed
Citation 2, item 7
29 CFR 1910.305(b)(2) · Electrical wiring methods
Other-than-serious$0$0Mar 27, 1996Closed
Citation 2, item 8
29 CFR 1910.305(g)(1)(iii) · Electrical wiring methods
Other-than-serious$0$0Mar 27, 1996Closed
Citation 2, item 9
29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods
Other-than-serious$0$0Mar 27, 1996Closed
Citation 2, item 10
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Mar 27, 1996Closed

Inspection 12690277 OPENED MAY 30, 1974Closed

Follow-up · Complete · Safety · 35 employees at the site · Closed Mar 10, 1984

511 Abbott Drive, Broomall, PA 19008 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 12699658 OPENED APR 25, 1974Closed

Planned · Complete · Safety · 35 employees at the site · Closed Mar 10, 1984

511 Abbott Drive, Broomall, PA 19032 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Other-than-serious$0$0Apr 26, 1974Closed
Citation 1, item 2
29 CFR 1910.212(b) · Machine guarding
Other-than-serious$0$0Apr 26, 1974Closed
Citation 1, item 3
29 CFR 1910.151(c) · First aid and eyewash
Other-than-serious$40$40Apr 26, 1974Closed
Citation 1, item 4
29 CFR 1904.2 · Partial exemption for establishments in certain industries
Other-than-serious$0$0Apr 26, 1974Closed
Citation 1, item 5
29 CFR 1904.5 · Determination of work-relatedness
Other-than-serious$0$0Apr 26, 1974Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.2 · Partial exemption for establishments in certain industries

29 CFR 1904.5 · Determination of work-relatedness

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(4)(i)

(4) Design and construction of inside storage rooms—(i) Construction. Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings shall be provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which dra

29 CFR 1910.106(d)(4)(iv)

(iv) Ventilation. Every inside storage room shall be provided with either a gravity or a mechanical exhaust ventilation system. Such system shall be designed to provide for a complete change of air within the room at least six times per hour. If a mechanical exhaust system is used, it shall be controlled by a switch located outside of the door. The ventilating equipment and any lighting fixtures shall be operated by the same switch. A pilot light shall be installed adjacent to the switch if Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), are dispensed within the room. Where gravity ventilation is provided, the fresh air intake, as well as the exhaust outlet from the room, shall be on the exterior of the building in which the room is located.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.212 · Machine guarding

29 CFR 1910.217 · Mechanical power presses

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.307 · Hazardous (classified) locations

29 CFR 1910.309

29 CFR 1910.36 · Exit route design

29 CFR 1910.37 · Exit routes

Other other motor vehicle parts manufacturing employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.