OSHA SearchOSHA records by employer

Davis H. Elliot Company, Inc.: OSHA inspections and violations

Oklahoma City, Oklahoma · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

6inspections
6citation items
$39,868current penalties
Feb 7, 2020last inspection

Davis H. Elliot Company, Inc. has 6 OSHA inspections on record in Oklahoma, the first in 2013.

OSHA's last visit started on Feb 7, 2020 as a planned inspection, in Oklahoma City.

Across those inspections OSHA issued 6 citation items: 2 serious and 4 other-than-serious.

OSHA proposed $54,380 in penalties. After settlements and reviews the total is $39,868, down 27%.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Davis H. Elliot Company, Inc. averages $15,184 over 2 cited inspections in that time.

2 inspections on this page followed a fatal incident.

Davis H. Elliot Company, Inc.: OSHA citation items per year, 2013 to 2020
Citation items per year, by inspection date.

Oklahoma · latest 90 days of OSHA records

56employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Oklahoma: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Oklahoma

Checking a subcontractor, a client or your own company? Watch Davis H. Elliot Company, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344617089 OPENED FEB 7, 2020Closed

Planned · Partial · Safety · 3 employees at the site · Closed May 20, 2020

1200 Ne 23rd Street, Oklahoma City, OK 73111 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.200(g)(2) · Accident prevention signs and tags
Other-than-serious$9,012$4,500Apr 10, 2020Final

Inspection 342806486 OPENED DEC 3, 2017Closed

Fatality or catastrophe · Partial · Safety · 2,100 employees at the site · Closed Oct 7, 2019

15700 Big Spring Drive, Oklahoma City, OK 73113 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Incident on Dec 2, 2017 (fatal): Employee is clearing job site with coworker and electrocutes

At 4:45 p.m. on December 2, 2017, an employee was assisting a coworker with trenching duties and tool cleanup. The employee was bringing some tools to the electrical pedestal for the residential property and come into contact with a live electrical wire. The employee was electrocuted.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 1926.952(b) · Job briefing
Other-than-serious$12,934$12,934May 30, 2018Final
Citation 1, item 3
29 CFR 1926.960(b)(1)(ii) · Working on or near exposed energized parts
Other-than-serious$12,934$12,934May 30, 2018Final

Inspection 340073923 OPENED NOV 7, 2014Closed

Planned · Complete · Safety · 150 employees at the site · Closed Feb 18, 2015

8314 E. 71st Street, Tulsa, OK 74133 · Power and Communication Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(c)(2) · Excavations
Other-than-serious$7,000$3,000Jan 6, 2015Final
Citation 1, item 3
29 CFR 1926.652(a)(1) · Trench protection
Serious$7,000$4,000Jan 6, 2015Final

Inspection 339429706 OPENED OCT 3, 2013Closed

Fatality or catastrophe · Partial · Safety · 500 employees at the site · Closed Jan 30, 2014

4016 Spyglass Road, Oklahoma City, OK 73142 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Incident on Oct 3, 2013 (fatal): Employee contacts an electrical power source and is killed

At approximately 2:00 p.m. on October 3, 2013, Employee #1 was installing and connecting electrical service. As he worked, he may have had a possible heart attack or contacted an electrical power source and was killed.

No citations from this inspection.

Inspection 338720055 OPENED FEB 5, 2013Open

Referral · Partial · Safety · Open

52148 W. 46th St. South, Oilton, OK 74052 · Power and Communication Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection so far.

Inspection 339041618 OPENED FEB 5, 2013Closed

Complaint · Partial · Safety · 1,400 employees at the site · Closed Sep 21, 2015

52148 W. 46th Street, Oilton, OK 74052 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.67(c)(2)(viii) · Vehicle-mounted elevating and rotating work platforms
Serious$5,500$2,500Jun 12, 2013Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.67 · Vehicle-mounted elevating and rotating work platforms

29 CFR 1910.67(c)(2)(viii)

(viii) An aerial lift truck may not be moved when the boom is elevated in a working position with men in the basket, except for equipment which is specifically designed for this type of operation in accordance with the provisions of paragraphs (b)(1) and (b)(2) of this section.

29 CFR 1926.200 · Accident prevention signs and tags

29 CFR 1926.200(g)(2)

(2) The design and use of all traffic control devices, including signs, signals, markings, barricades, and other devices, for protection of construction workers shall conform to Part 6 of the MUTCD (incorporated by reference, see § 1926.6).

29 CFR 1926.651 · Excavations

29 CFR 1926.651(c)(2)

(2) Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.

29 CFR 1926.652 · Trench protection

29 CFR 1926.952 · Job briefing

29 CFR 1926.960 · Working on or near exposed energized parts

Other electrical contractors and other wiring installation contractors employers in Oklahoma

Alert subscribers get notified of each newly cited employer in Oklahoma the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.