OSHA SearchOSHA records by employer

Dayton Lease & Pipeline Services, Inc.: OSHA inspections and violations

Deer Park, Texas · Oil and Gas Pipeline and Related Structures Construction · NAICS 237120

3inspections
4citation items
$20,297current penalties
Dec 6, 2023last inspection

Dayton Lease & Pipeline Services, Inc. has 3 OSHA inspections on record in Texas, the first in 2013.

OSHA's last visit started on Dec 6, 2023 as part of a related case, in Port Arthur, and the case has not closed yet.

Across those inspections OSHA issued 4 citation items: 4 serious.

OSHA proposed $35,826 in penalties. After settlements and reviews the total is $20,297, down 43%.

Most often, OSHA cited 1926.651, excavations (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Dayton Lease & Pipeline Services, Inc. averages $6,936 over 2 cited inspections in that time.

It reported 1 severe injury to OSHA since 2015.

Dayton Lease & Pipeline Services, Inc.: OSHA citation items per year, 2013 to 2023
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

404employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Dayton Lease & Pipeline Services, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347145948 OPENED DEC 6, 2023Open

Unprogrammed related · Partial · Safety · 9 employees at the site · Open

6300 W. Port Arthur Rd., Port Arthur, TX 77640 · Oil and Gas Pipeline and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.352(b) · Fire prevention
Serious$11,292$7,904May 28, 2024Final

Inspection 344070859 OPENED JUN 7, 2019Closed

Referral · Partial · Safety · 135 employees at the site · Closed Nov 13, 2019

5415 Avenue M, Santa Fe, TX 77510 · Oil and Gas Pipeline and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Incident on Jun 6, 2019: Two employees are burned in natural gas pipeline fire

At 6:15 p.m. on June 6, 2019, Employees #1 and #2 were repairing a natural gas pipe leak within an excavation. As the employees were performing the hot tap on the pipeline, a valve opened, causing a flash ignition of the gas and ensuing fire. There were several potential ignition sources within the excavation. The two employees were admitted to the hospital with burn to the face and arms.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$11,934$5,967Oct 3, 2019Final

Inspection 339363202 OPENED AUG 22, 2013Closed

Planned · Complete · Safety · 5 employees at the site · Closed Feb 26, 2014

586 East P Street, Deer Park, TX 77536 · Oil and Gas Pipeline and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.651(k)(1) · Excavations
Serious$6,300$6,426Dec 20, 2013Final
Citation 1, item 1b
29 CFR 1926.652(a)(1) · Trench protection
Serious$6,300$0Dec 20, 2013Final

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Jun 6, 2019, Santa Fe: Hospitalization · heat (thermal) burns, unspecified · nonclassifiable

Employees were using a tapping machine to perform a hot tap on a natural gas line. As the employees began a three-way bypass, a flash fire occurred. Two of the employees were hospitalized for burns.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.352 · Fire prevention

29 CFR 1926.352(b)

(b) If the object to be welded, cut, or heated cannot be moved and if all the fire hazards cannot be removed, positive means shall be taken to confine the heat, sparks, and slag, and to protect the immovable fire hazards from them.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(g)(1)(iii)

(iii) Adequate precaution shall be taken such as providing ventilation, to prevent employee exposure to an atmosphere containing a concentration of a flammable gas in excess of 20 percent of the lower flammable limit of the gas.

29 CFR 1926.651(k)(1)

(k) Inspections. (1) Daily inspections of excavations, the adjacent areas, and protective systems shall be made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection shall be conducted by the competent person prior to the start of work and as needed throughout the shift. Inspections shall also be made after every rainstorm or other hazard increasing occurrence. These inspections are only required when employee exposure can be reasonably anticipated.

29 CFR 1926.652 · Trench protection

Other oil and gas pipeline and related structures construction employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.