OSHA SearchOSHA records by employer

North Houston Pole Line, L.P.: OSHA inspections and violations

Houston, Texas · Power and Communication Line and Related Structures Construction · NAICS 237130

7inspections
5citation items
$51,014current penalties
Nov 16, 2026last inspection

North Houston Pole Line, L.P. has 7 OSHA inspections on record in Texas, the first in 2016.

OSHA's last visit started on Nov 16, 2026 on a referral, in Tomball, and the case has not closed yet.

Across those inspections OSHA issued 5 citation items: 1 serious and 4 other-than-serious.

OSHA proposed $59,240 in penalties. After settlements and reviews the total is $51,014, down 14%.

Most often, OSHA cited 1910.269, electric power generation, transmission, and distribution (2 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. North Houston Pole Line, L.P. averages $10,203 over 5 cited inspections in that time.

1 inspection on this page followed a fatal incident.

North Houston Pole Line, L.P. also files yearly injury logs with OSHA, summarized below.

It reported 3 severe injuries to OSHA since 2015.

North Houston Pole Line, L.P.: OSHA citation items per year, 2016 to 2026
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

394employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch North Houston Pole Line, L.P. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 349285361 OPENED NOV 16, 2026Open

Referral · Partial · Safety · 3 employees at the site · Open

12803 Madera Kanyon Lane, Tomball, TX 77377 · Power and Communication Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection so far.

Inspection 346765886 OPENED JUN 13, 2023Closed

Planned · Partial · Safety · 9 employees at the site · Closed Jun 13, 2025

Southwest Corner Of East Teralyn Way And Nocturne Ridge Drive 30.403811, -95.503699, Willis, TX 77318 · Power and Communication Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.651(j)(2) · Excavations
Other-than-serious$9,822$6,875Oct 12, 2023Final

Inspection 346052277 OPENED JUN 30, 2022Closed

Follow-up · Partial · Safety · 600 employees at the site · Closed Jul 14, 2022

1608 Margaret, Houston, TX 77093 · Power and Communication Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 344885777 OPENED AUG 18, 2020Closed

Referral · Partial · Safety · 5 employees at the site · Closed Jul 18, 2022

2312 Timbercreek Trail, Kingwood, TX 77345 · Power and Communication Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Incident on Aug 17, 2020: Employee receives electrical burns while working from utilit

At 10:10 a.m. on August 17, 2020, Employee #1 was working for a communication/power distribution contractor. Employee #1 climbed wooden pole to remove downed conductors. Employee contacted the bottom of the switch which was still energized from the underground circuit. Employee #1 suffered third degree burns to his arm and was hospitalized.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.269(d)(6)(vii) · Electric power generation, transmission, and distribution
Other-than-serious$13,494$13,494Dec 15, 2020Final

Inspection 344710371 OPENED MAR 25, 2020Closed

Fatality or catastrophe · Partial · Safety · 1,600 employees at the site · Closed Apr 14, 2022

12525 East I-10 Frontage, Baytown, TX 77523 · Power and Communication Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Incident on Mar 24, 2020 (fatal): Employee is killed when struck by pipe tongs while boring

At 9:00 a.m. on March 24, 2020, Employee #1 and some Coworkers, boring operators (crew), were running wire inside of drill stems, while installing a power transmission line and as his coworkers stopped to clean the mud pit, Employee #1 then placed a pipe tong on a stem. After the mud pit was cleaned, Coworker #1, a foreman, instructed the boring operator to initiate boring; however, the area surrounding the pipe stems was not cleared and as result, Employee #1 was struck in the back of the head by the pipe tong attached to the stem. Afterwards, Employee #1 sustained blunt force trauma to the head and was then transported to the hospital and later pronounced dead.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$13,494$10,120Sep 3, 2020Final

Inspection 342378940 OPENED JUN 7, 2017Closed

Referral · Partial · Safety · 600 employees at the site · Closed Oct 18, 2017

15482 Miller Rd. 1, Houston, TX 77049 · Power and Communication Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Incident on Jun 2, 2017: Employee installing utility pole incurs multiple fractures

At 11:30 a.m. on June 2, 2017, Employee #1 and Coworker #1, employed by a construction company, were engaged in setting a new Class 2 wooden utility pole. Coworker #1 was operating a digger derrick to move the pole. Employee #1 was assisting. Employee #1 was changing positions from one end of the pole to the other and was walking between the pole and the digger derrick. Coworker #1 released the machine's claws. The pole swung and pinned Employee #1 between the butt end of the pole and the digger derrick. Emergency services were called, and Employee #1 was transported to the hospital. He was admitted and treated for crushing injuries, including a fractured ulna and shattered radius in his forearm, fractured ribs, and a collapsed lung.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.753(d)(2)(i) · Hoisting and rigging
Other-than-serious$9,959$8,054Sep 6, 2017Final

Inspection 341637445 OPENED JUL 20, 2016Closed

Referral · Partial · Safety · 7 employees at the site · Closed May 1, 2017

15191 Lake View Drive, Beach City, TX 77523 · Power and Communication Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.269(q)(1)(i) · Electric power generation, transmission, and distribution
Other-than-serious$12,471$12,471Dec 16, 2016Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2022, the Houston site logged 18 recordable injuries or illnesses among about 1,134 workers: 1.1 per 100 full-time workers, against a median of 1.0 for its industry. Those cases cost 459 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
North Houston Pole Line, L.P.
Houston · 2022
1,134 1841.11.0
North Houston Pole Line L.P.
Houston · 2019
943 1451.11.0

Included with any plan: 4 more yearly logs from these sites, back to 2018, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 3 reports on file.

Jul 19, 2023, Houston: Hospitalization · heat exhaustion, prostration · body systems

An employee was working in the pole yard and suffered heat exhaustion. The employee was hospitalized.

Jul 16, 2021, Houston: Hospitalization · fractures · lower leg(s)

An employee was climbing down from a crane after loading it onto a lowboy trailer. He fell to the ground about 4 feet below and suffered a spiral fracture to the lower right leg.

Jun 2, 2017, Houston: Hospitalization · internal injuries to organs and blood vessels of the trunk · chest, except internal location of diseases or disorders

An employee was removing a wood utility pole from a hole when the pole slipped. The employee was then caught between the pole and an adjacent truck, suffering a collapsed lung and breaking ribs, an ulna, and a radius. The employee was hospitalized.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.269 · Electric power generation, transmission, and distribution

29 CFR 1910.269(d)(6)(vii)

(vii) Before starting work on machines or equipment that have been locked out or tagged out, the authorized employee shall verify that isolation and deenergizing of the machine or equipment have been accomplished. If normally energized parts will be exposed to contact by an employee while the machine or equipment is deenergized, a test shall be performed to ensure that these parts are deenergized.

29 CFR 1910.269(q)(1)(i)

(1) General. (i) Before allowing employees to subject elevated structures, such as poles or towers, to such stresses as climbing or the installation or removal of equipment may impose, the employer shall ascertain that the structures are capable of sustaining the additional or unbalanced stresses. If the pole or other structure cannot withstand the expected loads, the employer shall brace or otherwise support the pole or structure so as to prevent failure.

29 CFR 1926.651 · Excavations

29 CFR 1926.651(j)(2)

(2) Employees shall be protected from excavated or other materials or equipment that could pose a hazard by falling or rolling into excavations. Protection shall be provided by placing and keeping such materials or equipment at least 2 feet (.61 m) from the edge of excavations, or by the use of retaining devices that are sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary.

29 CFR 1926.753 · Hoisting and rigging

OSH Act Section 5 · General Duty Clause

Other power and communication line and related structures construction employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.