OSHA SearchOSHA records by employer

Delfingen US TX Inc.: OSHA inspections and violations

El Paso, Texas · Unlaminated Plastics Profile Shape Manufacturing · NAICS 326121

2inspections
3citation items
$12,500current penalties
Aug 27, 2024last inspection

Since 2017, OSHA inspectors have visited Delfingen US TX Inc. in Texas 2 times.

The most recent inspection opened on Aug 27, 2024 on a referral, in El Paso.

In all, OSHA issued 3 citation items: 2 serious and 1 other-than-serious.

The proposed penalties came to $20,887; today they stand at $12,500, 40% less.

The rule cited most here is 1910.147 (lockout/tagout), 3 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $4,500 penalty. Delfingen US TX Inc. averages $12,500 across 1 cited inspection.

It reported 3 severe injuries to OSHA since 2015.

Delfingen US TX Inc.: OSHA citation items per year, 2017 to 2024
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

394employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Delfingen US TX Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347714164 OPENED AUG 27, 2024Closed

Referral · Partial · Safety · 230 employees at the site · Closed Nov 12, 2024

12270 Rojas Drive Suite 300, El Paso, TX 79936 · Unlaminated Plastics Profile Shape Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342759909 OPENED NOV 8, 2017Closed

Referral · Partial · Safety · 237 employees at the site · Closed Aug 14, 2018

12270 Rojas Dr. Suite 300, El Paso, TX 79936 · Unlaminated Plastics Profile Shape Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Nov 7, 2017: Employee's finger is amputated while troubleshooting equipme

At 1:30 a.m. on November 7, 2017, an employee was troubleshooting equipment and the pulley and belt system of a piece of equipment, was still running. One of the employee's hands became caught and his finger was amputated.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(4)(ii) · Lockout/tagout
Serious$9,977$6,000Mar 22, 2018Final
Citation 1, item 2
29 CFR 1910.147(d)(2) · Lockout/tagout
Serious$9,977$6,000Mar 22, 2018Final
Citation 2, item 1
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Other-than-serious$933$500Mar 22, 2018Final

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 3 reports on file.

Aug 26, 2024, El Paso: Amputation · amputations, avulsions, enucleations unspecified · finger or thumb tip(s), nail(s)

An employee was working on a cutter machine and had an issue with the cutter block. The employee was attempting to correct the issue when the tip of their right little finger was amputated by the machine.

Apr 18, 2024, El Paso: Hospitalization · cuts, lacerations, punctures without injury to internal structures · part of body unspecified

An employee was operating a lamination machine and sustained a laceration from the blade. The employee was hospitalized for surgery.

Nov 10, 2020, El Paso: Hospitalization, amputation · amputations · finger(s), fingernail(s), n.e.c.

An employee was operating a lathe and suffered a finger amputation.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(4)(ii)

(ii) The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following:

29 CFR 1910.147(c)(6)(i)

(6) Periodic inspection. (i) The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.

29 CFR 1910.147(d)(2)

(2) Machine or equipment shutdown. The machine or equipment shall be turned off or shut down using the procedures established for the machine or equipment. An orderly shutdown must be utilized to avoid any additional or increased hazard(s) to employees as a result of the equipment stoppage.

Other unlaminated plastics profile shape manufacturing employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.