OSHA SearchOSHA records by employer

Delmarva Roofing and Coating, Inc.: OSHA inspections and violations

Ocean City, Maryland · Roofing Contractors · NAICS 238160

7inspections
36citation items
$13,280current penalties
Nov 4, 2021last inspection

OSHA has inspected Delmarva Roofing and Coating, Inc. 7 times in Maryland since 2008.

The latest one began on Nov 4, 2021 as a planned inspection, in Grasonville.

Those inspections ended with 36 citation items: 21 serious, 3 repeat and 12 other-than-serious.

Penalties were first proposed at $16,900 and now stand at $13,280, 21% lower after settlements or reviews.

Fall protection systems comes up most often in these citations: 7 items under 1926.502.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Delmarva Roofing and Coating, Inc. averages $1,025 (3 cited inspections).

Delmarva Roofing and Coating, Inc.: OSHA citation items per year, 2008 to 2021
Citation items per year, by inspection date.

Maryland · latest 90 days of OSHA records

182employers cited

30 of them in the same industry

Get notified the morning OSHA posts each new citation in Maryland: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Maryland

Checking a subcontractor, a client or your own company? Watch Delmarva Roofing and Coating, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345626535 OPENED NOV 4, 2021Closed

Planned · Complete · Safety · 8 employees at the site · Closed Mar 2, 2022

3028 Kent Narrows Way South, Grasonville, MD 21638 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.403(b)(2) · Electrical equipment on job sites
Serious$1,400$700Jan 21, 2022Final

Inspection 345360770 OPENED JUN 14, 2021Closed

Planned · Complete · Safety · 7 employees at the site · Closed Aug 11, 2021

200 Scheeler Road Chestertown, Maryland, Chestertown, MD 21620 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.502(b)(1) · Fall protection systems
Serious$375$375Jul 20, 2021Final
Citation 1, item 1b
29 CFR 1926.502(b)(9) · Fall protection systems
Serious$0$0Jul 20, 2021Final

Inspection 345176507 OPENED MAR 3, 2021Closed

Planned · Complete · Safety · 7 employees at the site · Closed May 25, 2021

219 Marlboro Avenue, Easton, MD 21601 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$1,750$1,750Apr 29, 2021Final
Citation 1, item 1b
29 CFR 1926.502(d)(6)(i) · Fall protection systems
Serious$0$0Apr 29, 2021Final
Citation 1, item 1c
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$0$0Apr 29, 2021Final
Citation 2, item 1
29 CFR 1926.503(b)(1) · Fall protection training in construction
Other-than-serious$250$250Apr 29, 2021Final

Inspection 339800880 OPENED JUN 2, 2014Closed

Planned · Complete · Safety · 8 employees at the site · Closed Jun 26, 2015

2410 North Zion Road, Salisbury, MD 21801 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1b
29 CFR 1910.1200(f)(6)(ii) · Hazard communication
Other-than-serious$0$800Aug 11, 2014Final
Citation 1, item 2a
29 CFR 1926.20(b)(2) · Construction safety programs
Other-than-serious$1,600$800Aug 11, 2014Final
Citation 1, item 2b
29 CFR 1926.21(b)(2) · Construction safety training
Serious$0$0Aug 11, 2014Final
Citation 1, item 3
29 CFR 1926.501(b)(4)(i) · Fall protection in construction
Serious$1,600$800Aug 11, 2014Final
Citation 1, item 4a
29 CFR 1926.502(f)(1) · Fall protection systems
Serious$1,400$1,400Aug 11, 2014Final
Citation 1, item 4d
29 CFR 1926.502(f)(2)(ii) · Fall protection systems
Serious$0$0Aug 11, 2014Final
Citation 1, item 4e
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$0$0Aug 11, 2014Final
Citation 2, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Repeat$2,800$2,800Aug 11, 2014Final
Citation 3, item 1
29 CFR 1910.1200(h)(3)(iv) · Hazard communication
Other-than-serious$0$0Aug 11, 2014Final
Citation 3, item 2
29 CFR 1926.403(b)(2) · Electrical equipment on job sites
Other-than-serious$0$0Aug 11, 2014Final
Citation 3, item 3
29 CFR 1926.416(e)(1) · Electrical safety in construction
Other-than-serious$0$0Aug 11, 2014Final
Citation 3, item 4
29 CFR 1926.502(i)(4) · Fall protection systems
Other-than-serious$0$0Aug 11, 2014Final
Citation 3, item 5
29 CFR 1926.503(b)(1) · Fall protection training in construction
Other-than-serious$0$0Aug 11, 2014Final

Inspection 317149722 OPENED MAY 21, 2013Closed

Planned · Complete · Safety · 3 employees at the site · Closed Aug 21, 2013

Building #5 12th Street, Ocean City, MD 21842 · Other Building Finishing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.502(b)(2) · Fall protection systems
Serious$1,050$565Jun 26, 2013Closed
Citation 1, item 2a
29 CFR 1926.1053(b)(4) · Ladders in construction
Serious$525$380Jun 26, 2013Closed
Citation 1, item 2b
29 CFR 1926.1053(b)(13) · Ladders in construction
Serious$0$0Jun 26, 2013Closed
Citation 2, item 1
29 CFR 50405 B01
Repeat$700$440Jun 26, 2013Closed
Citation 2, item 2
29 CFR 50406 A01
Repeat$300$190Jun 26, 2013Closed

Inspection 315975912 OPENED SEP 20, 2011Closed

Planned · Complete · Safety · 4 employees at the site · Closed Nov 15, 2011

12533 Ocean Gateway, Ocean City, MD 21842 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$900$565Oct 11, 2011Closed
Citation 2, item 1
29 CFR 50405 B01
Other-than-serious$0$0Oct 11, 2011Closed
Citation 2, item 2
29 CFR 50406 A01
Other-than-serious$0$0Oct 11, 2011Closed
Citation 2, item 3
29 CFR 50408 A01
Other-than-serious$0$0Oct 11, 2011Closed

Inspection 312438526 OPENED JUL 16, 2008Closed

Planned · Complete · Safety · 4 employees at the site · Closed Aug 21, 2008

107 Log Canoe Circle, Stevensville, MD 21666 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a Serious$750$512Aug 5, 2008Closed
Citation 1, item 1b
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$0$0Aug 5, 2008Closed
Citation 1, item 1c
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Aug 5, 2008Closed
Citation 1, item 2a
29 CFR 1926.501(b)(10) · Fall protection in construction
Serious$750$513Aug 5, 2008Closed
Citation 1, item 2b
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$0$0Aug 5, 2008Closed
Citation 1, item 3
29 CFR 1926.1051(a) · Stairways and Ladders: general requirements
Serious$750$440Aug 5, 2008Closed
Citation 2, item 1
29 CFR 1926.503(b)(1) · Fall protection training in construction
Other-than-serious$0$0Aug 5, 2008Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(f)(6)(ii)

(ii) Product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals, and which, in conjunction with the other information immediately available to employees under the hazard communication program, will provide employees with the specific information regarding the physical and health hazards of the hazardous chemical.

29 CFR 1910.1200(h)(3)(iv)

(iv) The details of the hazard communication program developed by the employer, including an explanation of the labels received on shipped containers and the workplace labeling system used by their employer; the safety data sheet, including the order of information and how employees can obtain and use the appropriate hazard information.

29 CFR 1926.1051 · Stairways and Ladders: general requirements

29 CFR 1926.1051(a)

(a) A stairway or ladder shall be provided at all personnel points of access where there is a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist is provided.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.21 · Construction safety training

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.454 · Scaffold training

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.502 · Fall protection systems

29 CFR 1926.503 · Fall protection training in construction

Other roofing contractors employers in Maryland

Alert subscribers get notified of each newly cited employer in Maryland the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.