OSHA SearchOSHA records by employer

Deltabjds, Inc.: OSHA inspections and violations

Philadelphia, Pennsylvania · Commercial and Institutional Building Construction · NAICS 236220

1inspections
3citation items
$24,197current penalties
May 8, 2024last inspection

Deltabjds, Inc. has one OSHA inspection on record in Pennsylvania.

OSHA opened it on May 8, 2024 after a fatality or catastrophe, in Philadelphia, and the case has not closed yet.

From that inspection OSHA issued 3 citation items: 1 serious and 2 other-than-serious.

OSHA proposed $24,197 in penalties and the amount has not been reduced.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Deltabjds, Inc. averages $24,197 over 1 cited inspection in that time.

1 inspection on this page followed a fatal incident.

Deltabjds, Inc.: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

297employers cited

4 of them in the same industry

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Deltabjds, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347468555 OPENED MAY 8, 2024Open

Fatality or catastrophe · Complete · Safety · 4 employees at the site · Open

6523 Lansdowne Ave, Philadelphia, PA 19151 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Incident on May 8, 2024 (fatal): Employee is electrocuted while using stud welder

At 12:11 p.m. on May 8, 2024, Employee #1 was installing insulation to ductwork while working on a ladder and using a stud welder. The employee received an electrical shock while using the stud welder, causing him to fall off the ladder to the ground. Emergency services responded, but the employee was pronounced dead from electrocution.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 1926.351(b)(4) · Arc welding and cutting
Other-than-serious$11,292$11,292Nov 6, 2024Final
Citation 1, item 4
29 CFR 1926.416(e)(1) · Electrical safety in construction
Serious$11,292$11,292Nov 6, 2024Final
Citation 2, item 1
29 CFR 1904.40(a) · Giving injury records to OSHA
Other-than-serious$1,613$1,613Nov 6, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.40 · Giving injury records to OSHA

29 CFR 1904.40(a)

(a) Basic requirement. When an authorized government representative asks for the records you keep under part 1904, you must provide copies of the records within four (4) business hours.

29 CFR 1926.351 · Arc welding and cutting

29 CFR 1926.351(b)(4)

(4) Cables in need of repair shall not be used. When a cable, other than the cable lead referred to in paragraph (b)(2) of this section, becomes worn to the extent of exposing bare conductors, the portion thus exposed shall be protected by means of rubber and friction tape or other equivalent insulation.

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.416(e)(1)

(e) Cords and cables. (1) Worn or frayed electric cords or cables shall not be used.

Other commercial and institutional building construction employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.