OSHA SearchOSHA records by employer

Denison Builders, Inc.: OSHA inspections and violations

Delhi, New York · Residential Remodelers · NAICS 236118

1inspections
9citation items
$6,991current penalties
Jun 19, 2018last inspection

OSHA has inspected Denison Builders, Inc. once in New York.

The inspection began on Jun 19, 2018 as a planned inspection, in Delhi.

That inspection ended with 9 citation items: 9 serious.

Penalties were first proposed at $11,641 and now stand at $6,991, 40% lower after settlements or reviews.

Job-site wiring comes up most often in these citations: 2 items under 1926.405.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Denison Builders, Inc. averages $6,991 (1 cited inspection).

Denison Builders, Inc.: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

356employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Denison Builders, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343241733 OPENED JUN 19, 2018Closed

Planned · Complete · Safety · 7 employees at the site · Closed Jul 23, 2021

59 Main Street, Delhi, NY 13753 · Residential Remodelers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.304(f) · Woodworking tools
Serious$2,772$1,666Aug 24, 2018Final
Citation 1, item 1b
29 CFR 1926.304(i)(1) · Woodworking tools
Serious$0$0Aug 24, 2018Final
Citation 1, item 2a
29 CFR 1926.403(b)(2) · Electrical equipment on job sites
Serious$2,217$1,330Aug 24, 2018Final
Citation 1, item 2b
29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites
Serious$0$0Aug 24, 2018Final
Citation 1, item 2c
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Serious$0$0Aug 24, 2018Final
Citation 1, item 2d
29 CFR 1926.405(a)(2)(ii)(i) · Job-site wiring
Serious$0$0Aug 24, 2018Final
Citation 1, item 2e
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Serious$0$0Aug 24, 2018Final
Citation 1, item 3
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$3,880$2,328Aug 24, 2018Final
Citation 1, item 4
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$2,772$1,666Aug 24, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.304 · Woodworking tools

29 CFR 1926.304(f)

(f) Other requirements. All woodworking tools and machinery shall meet other applicable requirements of American National Standards Institute, 01.1-1961, Safety Code for Woodworking Machinery.

29 CFR 1926.304(i)(1)

(i) Hand-fed ripsaws. (1) Each circular hand-fed ripsaw shall be guarded by a hood which shall completely enclose that portion of the saw above the table and that portion of the saw above the material being cut. The hood and mounting shall be arranged so that the hood will automatically adjust itself to the thickness of and remain in contact with the material being cut but it shall not offer any considerable resistance to insertion of material to saw or to passage of the material being sawed. The hood shall be made of adequate strength to resist blows and strains incidental to reasonable operation, adjusting, and handling, and shall be so designed as to protect the operator from flying splinters and broken saw teeth. It shall be made of material that is soft enough so that it will be unlikely to cause tooth breakage. The hood shall be so mounted as to insure that its operation will be po

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.501 · Fall protection in construction

Other residential remodelers employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.