Inspection 343416970 OPENED AUG 24, 2018Closed
216 Southgate Drive, Minster, OH 45865 · Other Industrial Machinery Manufacturing · OSHA's record · Phone and website on Google Maps
Incident on Aug 22, 2018: Employee suffers burns from hot water solution
At 9:30 a.m. on August 22, 2018, Employee #1 replacing the housing on the 282 valve cluster 282AV1342 located in the processing 282 area. The employee was working from below, laying on his back on the drain table located beneath valve cluster 282. As the employee was working, an adjacent valve, 282AV1230, was pulsed upstream with a caustic cleaning solution at 180 degrees Fahrenheit, into the same drain as the employee was lying. Employee #1 suffered severe burns to his arms, legs, and abdomen due to the high temperature of the solution. He was hospitalized for treatment. Same as #108587
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a OSH Act Section 5(a)(1) · General Duty Clause |
Serious | $13,260 | $8,619 | Feb 11, 2019 | Final |