Inspection 348485913 OPENED SEP 5, 2025Closed
U.s. Army Garrison-fort Buchanan, Fort Buchanan, PR 00934 · Industrial Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Toa Baja, Puerto Rico · Commercial and Institutional Building Construction · NAICS 236220
Since 2010, OSHA inspectors have visited Design Build, LLC in Puerto Rico 7 times.
The most recent inspection opened on Sep 5, 2025 to follow up on an earlier case, in Fort Buchanan.
In all, OSHA issued 6 citation items: 5 serious and 1 other-than-serious.
The proposed penalties came to $16,637; today they stand at $8,091, 51% less.
Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Design Build, LLC averages $6,831 across 1 cited inspection.
The Wage and Hour Division has 1 case on it since 2015, with $656 in back wages owed to workers.
Want to know if OSHA cites Design Build, LLC again? Add it to a watchlist and we will email you the morning the citation shows up.
Watch this companyU.s. Army Garrison-fort Buchanan, Fort Buchanan, PR 00934 · Industrial Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Road 865 Km 3.3 Bo Candelaria, Toa Baja, PR 00949 · Industrial Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Road 865 Km 3.3 Bo Candelaria, Toa Baja, PR 00949 · Industrial Building Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements |
Serious | $6,831 | $3,416 | Sep 20, 2023 | Final |
| Citation 1, item 2 29 CFR 1926.1053(b)(1) · Ladders in construction |
Serious | $6,831 | $3,416 | Sep 20, 2023 | Final |
Carretera Pr 618 Km 0.3, Morovis, PR 00687 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 2 29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites |
Serious | $700 | $350 | Oct 11, 2013 | Closed |
| Citation 1, item 4 29 CFR 1926.405(b)(1) · Job-site wiring |
Serious | $700 | $350 | Oct 13, 2013 | Closed |
| Citation 1, item 5 29 CFR 1926.501(b)(7)(ii) · Fall protection in construction |
Serious | $700 | $350 | Oct 13, 2013 | Closed |
Carr 618 Km 0.3 Morovis Sur, Morovis, PR 00687 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.119(h)(3)(ii) · Process safety management |
Other-than-serious | $875 | $210 | Nov 7, 2013 | Closed |
Carr 867 Int Ave Sabana Seca, Toa Baja, PR 00759 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Carr 865 Km 3 Hm 3 Candelaria, Toa Baja, PR 00951 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Cases by the Labor Department's Wage and Hour Division since 2015: unpaid minimum wage or overtime, child labor, family leave and more.
| Period reviewed | Violations | Workers owed | Back wages | Penalties |
|---|---|---|---|---|
| May 20, 2023 to May 16, 2025 TOA BAJA | 2 | 1 | $656 | $0 |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.1053(b)(1)
(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.
29 CFR 1926.404(b)(1)(ii)
(ii) Ground-fault circuit interrupters. All 120-volt, single-phase, 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, shall have approved ground-fault circuit interrupters for personnel protection. Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded surfaces, need not be protected with ground-fault circuit interrupters.
29 CFR 1926.405(b)(1)
(b) Cabinets, boxes, and fittings—(1) Conductors entering boxes, cabinets, or fittings. Conductors entering boxes, cabinets, or fittings shall be protected from abrasion, and openings through which conductors enter shall be effectively closed. Unused openings in cabinets, boxes, and fittings shall also be effectively closed.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.