Inspection 348956723 OPENED MAY 22, 2026Open
Ave. Kennedy, Km 3.5, Lote 9, San Juan, PR 00920 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection so far.
San Juan, Puerto Rico · Commercial and Institutional Building Construction · NAICS 236220
Since 2020, OSHA inspectors have visited Dev Builders Group LLC in Puerto Rico 3 times.
The most recent inspection opened on May 22, 2026 as part of a related case, in San Juan and is still open.
In all, OSHA issued 6 citation items: 6 serious.
The proposed penalties came to $19,872; today they stand at $5,960, 70% less.
Among construction employers, the typical cited inspection since 2015 ends with a $3,078 penalty. Dev Builders Group LLC averages $5,960 across 1 cited inspection.
Want to know if OSHA cites Dev Builders Group LLC again? Add it to a watchlist and we will email you the morning the citation shows up.
Watch this companyAve. Kennedy, Km 3.5, Lote 9, San Juan, PR 00920 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection so far.
Marginal Kennedy Sector Bechara Km 2.1, San Juan, PR 00920 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.403(b)(2) · Electrical equipment on job sites |
Serious | $3,060 | $918 | Jul 16, 2024 | Final |
| Citation 1, item 2 29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites |
Serious | $3,060 | $918 | Jul 16, 2024 | Final |
| Citation 1, item 3 29 CFR 1926.405(b)(1) · Job-site wiring |
Serious | $1,836 | $550 | Jul 16, 2024 | Final |
| Citation 1, item 4 29 CFR 1926.501(b)(1) · Fall protection in construction |
Serious | $5,040 | $1,512 | Jul 16, 2024 | Final |
| Citation 1, item 5 29 CFR 1926.503(a)(1) · Fall protection training in construction |
Serious | $5,040 | $1,512 | Jul 16, 2024 | Final |
| Citation 1, item 6 29 CFR 1926.1053(b)(13) · Ladders in construction |
Serious | $1,836 | $550 | Jul 16, 2024 | Final |
Carr 1 Km 55 Ramal 735 Bo. Montellano, Cayey, PR 00736 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.1053(b)(13)
(13) The top or top step of a stepladder shall not be used as a step.
29 CFR 1926.403(b)(2)
(2) Installation and use. Listed, labeled, or certified equipment shall be installed and used in accordance with instructions included in the listing, labeling, or certification.
29 CFR 1926.404(b)(1)(i)
(b) Branch circuits—(1) Ground-fault protection—(i) General. The employer shall use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. These requirements are in addition to any other requirements for equipment grounding conductors.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.