Inspection 347590622 OPENED JUN 21, 2024Closed
Carr. 955 Bo. Palmeras, Rio Grande, PR 00745 · Steel Foundries (except Investment) · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Dorado, Puerto Rico · Commercial and Institutional Building Construction · NAICS 236220
Since 2023, OSHA inspectors have visited DFM Contractor L.L.C. in Puerto Rico 2 times.
The most recent inspection opened on Jun 21, 2024 on a referral, in Rio Grande.
In all, OSHA issued 11 citation items: 11 serious.
The proposed penalties came to $39,240; today they stand at $18,650, 52% less.
The rule cited most here is 1926.405 (job-site wiring), 2 times.
Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. DFM Contractor L.L.C. averages $18,650 across 1 cited inspection.
Puerto Rico · latest 90 days of OSHA records
110employers cited
8 of them in the same industry
Get notified the morning OSHA posts each new citation in Puerto Rico: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Puerto Rico
Checking a subcontractor, a client or your own company? Watch DFM Contractor L.L.C. and get notified the morning OSHA posts a new citation for it.
Watch this companyCarr. 955 Bo. Palmeras, Rio Grande, PR 00745 · Steel Foundries (except Investment) · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Calle Boqueron, Sector Arenales, Dorado, PR 00646 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.25(a) · Housekeeping |
Serious | $3,400 | $1,865 | Oct 31, 2023 | Final |
| Citation 1, item 2 29 CFR 1926.350(a)(10) · Gas welding and cutting |
Serious | $2,040 | $0 | Oct 31, 2023 | Final |
| Citation 1, item 3 29 CFR 1926.404(b)(1)(i) · Ground-fault protection on job sites |
Serious | $3,400 | $1,865 | Oct 31, 2023 | Final |
| Citation 1, item 4 29 CFR 1926.404(f)(6) · Ground-fault protection on job sites |
Serious | $1,700 | $1,865 | Oct 31, 2023 | Final |
| Citation 1, item 5 29 CFR 1926.405(g)(1)(iii) · Job-site wiring |
Serious | $1,700 | $1,865 | Oct 31, 2023 | Final |
| Citation 1, item 6 29 CFR 1926.405(g)(2)(iv) · Job-site wiring |
Serious | $3,400 | $1,865 | Oct 31, 2023 | Final |
| Citation 1, item 7 29 CFR 1926.451(e)(2)(vi) · Scaffolds, general requirements |
Serious | $3,400 | $1,865 | Oct 31, 2023 | Final |
| Citation 1, item 8 29 CFR 1926.454(c) · Scaffold training |
Serious | $3,400 | $1,865 | Oct 31, 2023 | Final |
| Citation 1, item 9 29 CFR 1926.501(b)(1) · Fall protection in construction |
Serious | $5,600 | $1,865 | Oct 31, 2023 | Final |
| Citation 1, item 10 29 CFR 1926.701(b) · Concrete and Masonry Construction: general requirements |
Serious | $5,600 | $1,865 | Oct 31, 2023 | Final |
| Citation 1, item 11 29 CFR 1926.1053(b)(1) · Ladders in construction |
Serious | $5,600 | $1,865 | Oct 31, 2023 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.1053(b)(1)
(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.
29 CFR 1926.25(a)
(a) During the course of construction, alteration, or repairs, form and scrap lumber with protruding nails, and all other debris, shall be kept cleared from work areas, passageways, and stairs, in and around buildings or other structures.
29 CFR 1926.350(a)(10)
(10) Oxygen cylinders in storage shall be separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour.
Alert subscribers get notified of each newly cited employer in Puerto Rico the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.