OSHA SearchOSHA records by employer

Diamond Electric Manufacturing Corporation: OSHA inspections and violations

Eleanor, West Virginia · Motor Vehicle Electrical and Electronic Equipment Manufacturing · NAICS 336322

2inspections
2citation items
$8,502current penalties
Jan 9, 2020last inspection

OSHA has inspected Diamond Electric Manufacturing Corporation 2 times in West Virginia since 2005.

The latest one began on Jan 9, 2020 on a referral, in Eleanor.

Those inspections ended with 2 citation items: 2 serious.

Penalties were first proposed at $12,145 and now stand at $8,502, 30% lower after settlements or reviews.

Lockout/tagout comes up most often in these citations: 2 items under 1910.147.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Diamond Electric Manufacturing Corporation averages $8,502 (1 cited inspection).

It reported 1 severe injury to OSHA since 2015.

Diamond Electric Manufacturing Corporation: OSHA citation items per year, 2005 to 2020
Citation items per year, by inspection date.

West Virginia · latest 90 days of OSHA records

27employers cited

Get notified the morning OSHA posts each new citation in West Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in West Virginia

Checking a subcontractor, a client or your own company? Watch Diamond Electric Manufacturing Corporation and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344549134 OPENED JAN 9, 2020Closed

Referral · Partial · Safety · 230 employees at the site · Closed Oct 6, 2020

State Route 62, Eleanor, WV 25070 · All Other Miscellaneous Electrical Equipment and Component Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Jan 3, 2020: Employee fractures arm when caught in machine while performi

At 2:45 a.m. on January 3, 2020, an employee was working for a firm that manufactured miscellaneous electrical equipment and components. He worked as a maintenance technician. He was repairing the facility's automatic coil assembly machine number 8, in the assembly area. The machine was powered by more than one energy source. It had a source of pneumatic energy, compressed air at 87 psi (600 kPa), and a source of electricity, at 208 volts three-phase. Employees performed maintenance and testing on different machines in the facility on a daily basis. In addition, employees also performed testing in conjunction with the maintenance activities. During maintenance or testing, typically a machine was placed in manual mode, but it was not locked out, and the power remained on. The coil assembly machine was hardwired into its power supply. In this incident, the turntable of the automatic coil assembly machine activated while the employee was performing maintenance. The employee's arm was pinned between the turntable and the machines post. The employee's arm was broken, and the employee was hospitalized as an inpatient. Technicians were in the habit of placing the machine in manual mode to test the machine operations prior to and after repairs. Employees stated that it was more convenient to leave the machine on. The firm's maintenance supervisor and operations superintendent were aware that employees performed repairs on this and other machines by placing the machines in manual mode, which bypassed interlock guards. Both were aware that machines were typically not locked out during maintenance. Employees were not aware of any specific lockout/tagout (LOTO) procedures.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$12,145$8,502Apr 1, 2020Final
Citation 1, item 1b
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$0$0Apr 1, 2020Final

Inspection 307072579 OPENED JUN 16, 2005Closed

Complaint · Partial · Health · 120 employees at the site · Closed Jun 16, 2005

Sr 62 Eleanor Industrial Park, Eleanor, WV 25070 · Motor Vehicle Electrical and Electronic Equipment Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Jan 3, 2020, Eleanor: Hospitalization · fractures · arm(s), unspecified

An employee was repairing an assembly machine. The turntable activated and his arm was trapped in the machine and broken.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(4)(i)

(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.

29 CFR 1910.147(c)(6)(i)

(6) Periodic inspection. (i) The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.

Other motor vehicle electrical and electronic equipment manufacturing employers in West Virginia

Alert subscribers get notified of each newly cited employer in West Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.