OSHA SearchOSHA records by employer

Direct Wood Products, Inc.: OSHA inspections and violations

New Kent, Virginia · Wood Container and Pallet Manufacturing · NAICS 321920

8inspections
60citation items
$16,684current penalties
Apr 15, 2022last inspection

Direct Wood Products, Inc. has 8 OSHA inspections on record in Virginia, the first in 1999.

OSHA's last visit started on Apr 15, 2022 as a planned inspection, in West Point.

Across those inspections OSHA issued 60 citation items: 36 serious, 2 repeat and 22 other-than-serious.

OSHA proposed $24,635 in penalties. After settlements and reviews the total is $16,684, down 32%.

Most often, OSHA cited 1910.157, portable fire extinguishers (8 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. Direct Wood Products, Inc. averages $6,912 over 1 cited inspection in that time.

Direct Wood Products, Inc.: OSHA citation items per year, 1999 to 2022
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

253employers cited

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch Direct Wood Products, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345901532 OPENED APR 15, 2022Closed

Planned · Complete · Safety · 20 employees at the site · Closed Dec 15, 2022

18503 Eltham Road, West Point, VA 23181 · Wood Container and Pallet Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.101(b) · Compressed gases (general requirements)
Serious$2,080$1,456Jul 19, 2022Final
Citation 1, item 1b
29 CFR 1910.110(d)(10) · Storage and handling of liquefied petroleum gases
Serious$0$0Jul 19, 2022Final
Citation 1, item 2
29 CFR 1910.212(a)(1) · Machine guarding
Other-than-serious$3,975$2,544Jul 19, 2022Final
Citation 1, item 3
29 CFR 1910.213(a)(9) · Woodworking machinery
Serious$2,080$1,456Jul 19, 2022Final
Citation 1, item 4
29 CFR 1910.304(g)(5) · Grounding and circuit protection
Serious$2,080$1,456Jul 19, 2022Final
Citation 2, item 1
29 CFR 1910.151(c) · First aid and eyewash
Other-than-serious$0$0Jul 19, 2022Final
Citation 2, item 2
29 CFR 1910.303(b)(8)(i) · Electrical equipment, general requirements
Other-than-serious$0$0Jul 19, 2022Final

Inspection 345089619 OPENED JAN 7, 2021Closed

Planned · Complete · Health · 24 employees at the site · Closed Mar 11, 2021

18503 & 18501 Eltham Road, West Point, VA 23181 · Wood Container and Pallet Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 313123887 OPENED APR 14, 2009Closed

Planned · Complete · Health · 25 employees at the site · Closed Apr 14, 2009

18501 Eltham Road, West Point, VA 23181 · Wood Container and Pallet Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 310742317 OPENED JAN 25, 2007Closed

Monitoring · Partial · Safety · 40 employees at the site · Closed Jan 25, 2007

18501 Eltham Road, New Kent, VA 23181 · Wood Container and Pallet Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 310575345 OPENED NOV 20, 2006Closed

Planned · Complete · Safety · 40 employees at the site · Closed Jan 31, 2007

18501 Eltham Road, New Kent, VA 23181 · Wood Container and Pallet Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$1,225$735Jan 4, 2007Closed
Citation 1, item 2
29 CFR 1910.213(s)(9) · Woodworking machinery
Serious$1,225$735Jan 4, 2007Closed
Citation 1, item 3
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$700$420Jan 4, 2007Closed
Citation 1, item 4a
29 CFR 1910.303(b)(1) · Electrical equipment, general requirements
Serious$700$420Jan 4, 2007Closed
Citation 1, item 4b
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$0$0Jan 4, 2007Closed
Citation 1, item 5
29 CFR 1910.303(f) · Electrical equipment, general requirements
Serious$700$420Jan 4, 2007Closed
Citation 2, item 1
29 CFR 1910.37(b)(2) · Exit routes
Other-than-serious$0$0Jan 4, 2007Closed
Citation 2, item 2
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0Jan 4, 2007Closed
Citation 2, item 3
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Jan 4, 2007Closed
Citation 2, item 4
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Jan 4, 2007Closed

Inspection 304773211 OPENED JAN 22, 2002Closed

Planned · Complete · Health · 20 employees at the site · Closed May 14, 2002

18501 Eltham Road, New Kent, VA 23181 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$900$540Mar 22, 2002Closed
Citation 1, item 2 Serious$900$540Mar 22, 2002Closed
Citation 1, item 3a
29 CFR 1910.134(e)(6)(i) · Respiratory protection
Serious$900$540Mar 22, 2002Closed
Citation 1, item 3b
29 CFR 1910.134(c)(2)(i) · Respiratory protection
Serious$0$0Mar 22, 2002Closed
Citation 1, item 3c
29 CFR 1910.134(c)(2)(ii) · Respiratory protection
Serious$0$0Mar 22, 2002Closed
Citation 1, item 3d
29 CFR 1910.134(c)(3) · Respiratory protection
Serious$0$0Mar 22, 2002Closed
Citation 1, item 3e
29 CFR 1910.134(d)(1)(iii) · Respiratory protection
Serious$0$0Mar 22, 2002Closed
Citation 1, item 4a
29 CFR 1910.146(c)(2) · Permit-required confined spaces
Serious$900$540Mar 22, 2002Closed
Citation 1, item 4b
29 CFR 1910.146(c)(4) · Permit-required confined spaces
Serious$0$0Mar 22, 2002Closed
Citation 1, item 4c
29 CFR 1910.146(c)(7)(iii) · Permit-required confined spaces
Serious$0$0Mar 22, 2002Closed
Citation 1, item 4d
29 CFR 1910.146(g)(1) · Permit-required confined spaces
Serious$0$0Mar 22, 2002Closed
Citation 2, item 1
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$0$0Mar 22, 2002Closed
Citation 2, item 2
29 CFR 1910.147(c)(4)(ii) · Lockout/tagout
Other-than-serious$0$0Mar 18, 2002Closed
Citation 2, item 3
29 CFR 1910.1200(e)(1)(i) · Hazard communication
Other-than-serious$0$0Mar 22, 2002Closed
Citation 2, item 4
29 CFR 1910.1200(g)(1) · Hazard communication
Other-than-serious$0$0Mar 22, 2002Closed

Inspection 304532880 OPENED SEP 18, 2001Closed

Referral · Partial · Safety · 28 employees at the site · Closed Oct 17, 2001

18501 Eltham Road, New Kent, VA 23181 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$1,575$1,575Sep 28, 2001Closed
Citation 2, item 1
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Repeat$120$120Sep 28, 2001Closed
Citation 2, item 2
29 CFR 1910.157(g)(2) · Portable fire extinguishers
Repeat$1,800$1,800Sep 28, 2001Closed

Inspection 302589858 OPENED APR 26, 1999Closed

Planned · Complete · Safety · 25 employees at the site · Closed Jun 2, 1999

18501 Eltham Road, New Kent, VA 23181 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$225$112May 13, 1999Closed
Citation 1, item 1b
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Serious$0$0May 13, 1999Closed
Citation 1, item 2a
29 CFR 1910.157(g)(1) · Portable fire extinguishers
Serious$225$112May 13, 1999Closed
Citation 1, item 2b
29 CFR 1910.157(g)(2) · Portable fire extinguishers
Serious$0$0May 13, 1999Closed
Citation 1, item 3
29 CFR 1910.178(m)(7) · Forklifts and other powered industrial trucks
Serious$300$150May 13, 1999Closed
Citation 1, item 4a
29 CFR 1910.215(a)(2) · Grinders and abrasive wheels
Serious$300$150May 13, 1999Closed
Citation 1, item 4b
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$0$0May 13, 1999Closed
Citation 1, item 4c
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$0$0May 13, 1999Closed
Citation 1, item 5a
29 CFR 1910.213(h)(1) · Woodworking machinery
Serious$525$262May 13, 1999Closed
Citation 1, item 5b
29 CFR 1910.213(h)(3) · Woodworking machinery
Serious$0$0May 13, 1999Closed
Citation 1, item 6
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$300$150May 13, 1999Closed
Citation 1, item 7
29 CFR 1910.303(f) · Electrical equipment, general requirements
Serious$300$150May 13, 1999Closed
Citation 1, item 8
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$300$150May 13, 1999Closed
Citation 1, item 9
29 CFR 1910.305(b)(1) · Electrical wiring methods
Serious$300$150May 13, 1999Closed
Citation 2, item 1
29 CFR ARM0060 A
Other-than-serious$0$0May 13, 1999Closed
Citation 2, item 2
29 CFR 1910.23(d)(1)(ii) · Guarding floor and wall openings and holes
Other-than-serious$0$0May 13, 1999Closed
Citation 2, item 3
29 CFR 1910.37(q)(1) · Exit routes
Other-than-serious$0$0May 13, 1999Closed
Citation 2, item 4
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0May 13, 1999Closed
Citation 2, item 5
29 CFR 1910.157(c)(4) · Portable fire extinguishers
Other-than-serious$0$0May 13, 1999Closed
Citation 2, item 6
29 CFR 1910.157(e)(3) · Portable fire extinguishers
Other-than-serious$0$0May 13, 1999Closed
Citation 2, item 7
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Other-than-serious$0$0May 13, 1999Closed
Citation 2, item 8
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0May 13, 1999Closed
Citation 2, item 9
29 CFR 1910.1200(f)(5)(i) · Hazard communication
Other-than-serious$0$0May 13, 1999Closed
Citation 2, item 10
29 CFR 1910.1200(f)(5)(ii) · Hazard communication
Other-than-serious$0$0May 13, 1999Closed
Citation 2, item 11
29 CFR 1910.1200(h) · Hazard communication
Other-than-serious$0$0May 13, 1999Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.101 · Compressed gases (general requirements)

29 CFR 1910.101(b)

(b) Compressed gases. The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in § 1910.6.

29 CFR 1910.110 · Storage and handling of liquefied petroleum gases

29 CFR 1910.110(d)(10)

(10) Damage from vehicles. When damage to LP-Gas systems from vehicular traffic is a possibility, precautions against such damage shall be taken.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.146 · Permit-required confined spaces

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.37 · Exit routes

29 CFR 1910.95 · Noise

Other wood container and pallet manufacturing employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.