OSHA SearchOSHA records by employer

District Electrical Services, Inc.: OSHA inspections and violations

Washington, District of Columbia · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

4inspections
5citation items
$2,528current penalties
Jun 20, 2019last inspection

Since 2000, OSHA inspectors have visited District Electrical Services, Inc. in District of Columbia 4 times.

The most recent inspection opened on Jun 20, 2019 on a referral, in Washington.

In all, OSHA issued 5 citation items: 2 serious and 3 other-than-serious.

The proposed penalties came to $3,403; today they stand at $2,528, 26% less.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. District Electrical Services, Inc. averages $564 across 2 cited inspections.

1 inspection on this page followed a fatal incident.

District Electrical Services, Inc. also files yearly injury logs with OSHA, summarized below.

District Electrical Services, Inc.: OSHA citation items per year, 2000 to 2019
Citation items per year, by inspection date.

District of Columbia · latest 90 days of OSHA records

14employers cited

Get notified the morning OSHA posts each new citation in District of Columbia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in District of Columbia

Checking a subcontractor, a client or your own company? Watch District Electrical Services, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344103379 OPENED JUN 20, 2019Closed

Referral · Partial · Health · 12 employees at the site · Closed Jul 14, 2021

211 Elm St., Nw, Washington, DC 20001 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Incident on Jun 18, 2019: Employee fractures legs in fall down stairs

At 9:45 a.m. on June 18, 2019, Employee #1, employed by an electrical contractor, was engaged in installation work at a two-story multifamily residential building. He was preparing to move his tools and a portable stepladder from one work location on the first floor to another in the lobby. The employee lost his footing and fell down a single flight of stairs onto a concrete floor. The employee was transported to the hospital and admitted for treatment of fractures to both legs.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 2, item 1
29 CFR 1904.4(a) · Recording criteria
Other-than-serious$1,128$1,128Dec 17, 2019Final

Inspection 344084561 OPENED JUN 12, 2019Closed

Referral · Partial · Safety · 19 employees at the site · Closed Jul 30, 2019

618 T Street, Nw, Washington, DC 20003 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Incident on Jun 11, 2019 (fatal): Employee dies of apparent drug overdose

At 1:30 p.m. on June 11, 2019, Employee #1, employed by an electrical services company, was working at a multiemployer construction project, a six-story multifamily residential structure. He was caulking wire penetrations when he lost consciousness. Emergency services were called, and upon their arrival Employee #1 was determined to have died. The apparent cause of death was a drug overdose.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1904.41(a)(1) · Electronic submission of Employer Identification Number (EIN) and injury and illness records to OSHA
Other-than-serious$0$0Jun 26, 2019Final

Inspection 311025522 OPENED MAY 9, 2007Closed

Referral · Complete · Safety · 4 employees at the site · Closed May 29, 2007

1525 Alabama Avenue, Se, Washington, DC 20032 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.95(a) · Criteria for personal protective equipment
Serious$875$400May 18, 2007Closed
Citation 1, item 2
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$875$475May 18, 2007Closed

Inspection 301472007 OPENED JUL 6, 2000Closed

Referral · Partial · Safety · 2 employees at the site · Closed Aug 28, 2000

4306 S. Capital St. S.e., Washington, DC 20374 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.416(a)(1) · Electrical safety in construction
Other-than-serious$525$525Jul 17, 2000Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2021, the Washington site logged 1 recordable injury or illness among about 46 workers: 2.4 per 100 full-time workers, against a median of 1.8 for its industry. Those cases cost 3 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
District Electrical Services
Washington · 2021
46 112.41.8

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.4 · Recording criteria

29 CFR 1904.4(a)

(a) Basic requirement. Each employer required by this part to keep records of fatalities, injuries, and illnesses must record each fatality, injury and illness that:

29 CFR 1904.41 · Electronic submission of Employer Identification Number (EIN) and injury and illness records to OSHA

29 CFR 1904.41(a)(1)

(a) Basic requirements—(1) Annual electronic submission of information from OSHA Form 300A Summary of Work-Related Injuries and Illnesses. (i) If your establishment had 20-249 employees at any time during the previous calendar year, and your establishment is classified in an industry listed in appendix A to subpart E of this part, then you must electronically submit information from OSHA Form 300A Summary of Work-Related Injuries and Illnesses to OSHA or OSHA's designee. You must submit the information once a year, no later than the date listed in paragraph (c) of this section of the year after the calendar year covered by the form.

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.416(a)(1)

(a) Protection of employees. (1) No employer shall permit an employee to work in such proximity to any part of an electric power circuit that the employee could contact the electric power circuit in the course of work, unless the employee is protected against electric shock by deenergizing the circuit and grounding it or by guarding it effectively by insulation or other means.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.95 · Criteria for personal protective equipment

Other electrical contractors and other wiring installation contractors employers in District of Columbia

Alert subscribers get notified of each newly cited employer in District of Columbia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.